Records from 1985 to 1997. Most recent: inspection, 6 May 1997.
Inspection history · 18
6 May 1997
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 403280
27 April 1997
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 402982
13 December 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 448532
10 December 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 398245
21 December 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 373475
21 December 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1161646
2 August 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 369491
2 August 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 861198
13 October 1993
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 361463
30 March 1993
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 649289
29 March 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 528142
24 March 1993
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 357026
23 January 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 348330
23 May 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 456564
2 December 1988
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 327142
26 May 1987
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 316311
11 June 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 480256
6 December 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 305765
Engineering
Issued 27 April 1997
Resolved
Containment on main deck had no means of closure.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Electrical
Issued 27 April 1997
Resolved
Emergency battery back ups for essential bridge electronics were dead and failed to take charge.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Fire Fighting
Issued 27 April 1997
Resolved
Fire doors, port side, main deck, just inside the deckhouse off the passageway. Gray steel double door hinges are broken and doors don't open or close properly.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Lifesaving
Issued 27 April 1997
Resolved
Several oxyacetylene tanks were on the main deck without caps and not properly stowed in racks.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Electrical
Issued 27 April 1997
Resolved
Port side, main deck just inside deck house. 220 power box plug covers are wasted and won't close exposing internal prongs to the elements.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Lifesaving
Issued 27 April 1997
Resolved
Excessive oil in engine room on deck and equipment.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Navigation
Issued 27 April 1997
Resolved
Excessive oil in steering space.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Engineering
Issued 27 April 1997
Resolved
O.W.S failed to perform 15 ppm alarm test. Engineer claimed problem was a wasted sensor. Oil waste tank was full to capacity.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Lifesaving
Issued 27 April 1997
Resolved
EPIRB hydro release was outdated and breakable plastic bolt had been replaced with a steel bolt preventing EPIRB from floating free regardless of hydrostatic release.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Engineering
Issued 27 April 1997
Resolved
Semi-portable foam fire extinguisher discharge hose was cracked and dry rotted.
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Documentation
Issued 10 December 1996
Resolved
Provide onboard training manual for lifesaving as per SOLAS 74, III/51.
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Lifesaving
Issued 10 December 1996
Resolved
Properly stow all flammable liquids into paint locker prior to departure Port of Houston._x001C_ _x001C_ SOLAS 74, II-2/18.7
Condition: Unknown
Due 12 December 1996
Resolved 19 December 1996
Fire Fighting
Issued 10 December 1996
Resolved
Service all fire extinguishers in the machinery space. Provide service report to Coast Guard._x001C_ _x001C_ SOLAS 74, II-2/21
Condition: Unknown
Due 15 December 1996
Resolved 19 December 1996
Documentation
Issued 10 December 1996
Resolved
Provide onboard maintenance manual for lifesaving equipment as per _x001C_ SOLAS 74, III/52.
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Lifesaving
Issued 10 December 1996
Resolved
Properly install weak-link on starboard liferaft._x001C_ _x001C_ _x001C_ SOLAS 74, III/38/6.2
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Fire Fighting
Issued 10 December 1996
Resolved
Replace holed fire hoses on bridge, engineroom and main deck fire stations._x001C_ _x001C_ SOLAS 74 II-2/21
Condition: Unknown
Due 15 December 1996
Resolved 19 December 1996
Documentation
Issued 10 December 1996
Resolved
Provide onboard waste management plan as per MARPOL V/4.2
Condition: Unknown
Due 10 January 1997
Resolved 19 December 1996
Deck/Cargo
Issued 10 December 1996
Resolved
Repair and demonstrate proper operation of cargo ventilators that are frozen open (1S, 2S, 3P, 5S, & 5P). Provide flag state report to U.S. Coast Guard._x001C_ ILLC 66 Annex I/19
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Engineering
Issued 10 December 1996
Resolved
Repair and demonstrate proper operation of oily water separator. Provide flag state report to Coast Guard._x001C_ _x001C_ MARPOL I/16
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Electrical
Issued 10 December 1996
Resolved
Repair/replace light fixtures on the main deck foot locker, main deck, and forward bos'n stores that have broken lamps and exposed wiring. Provide Flag State report to Coast Guard._x001C_ SOALS 60, II/27
Condition: Unknown
Due 6 May 1997
Resolved 6 May 1997
Lifesaving
Issued 10 December 1996
Resolved
Stow lifeboat equipment in watertight containers. Provide Flag state report to Coast Guard._x001C_ _x001C_ SOLAS 60, III/11
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Lifesaving
Issued 10 December 1996
Resolved
Replace dry-rotted sea anchor line. Provide flag state report to Coast Guard._x001C_ _x001C_ SOLAS 60, III/11
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Lifesaving
Issued 10 December 1996
Resolved
Repair/Replace lights for ring bouys on port and stbdside main deck. Provide flag state report to Coast Guard._x001C_ _x001C_ SOLAS 60, III/21
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Deck/Cargo
Issued 10 December 1996
Resolved
Make permanent repairs to temporary patches on port and stbs anchor windlass hydraulic lines. Provide flag state report to Coast Guard.
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Construction/Loadline
Issued 10 December 1996
Resolved
Repair and demonstate proper operation of cargo hatch covers prior to loading cargo. Provide class report to U.S. Coast Guard._x001C_ _x001C_ ILO-147
Condition: Unknown
Due 15 December 1996
Resolved 19 December 1996
Documentation
Issued 10 December 1996
Resolved
Provide onboard crew IAW Safe Manning Document prior to departure Port of Houston._x001C_ _x001C_ STCW I/4
Condition: Unknown
Due 12 December 1996
Resolved 19 December 1996
Navigation
Issued 10 December 1996
Resolved
Demonstrate proper operation of alternative steering system. Provide flag state report prior to departure Port of Houston._x001C_ _x001C_ SOLAS 60, II/29
Condition: Unknown
Due 12 December 1996
Resolved 19 December 1996
Lifesaving
Issued 10 December 1996
Resolved
Demonstrate proper operation of port and starboard lifeboat engines. Provide flag state report to Coast Guard._x001C_ (Vessel authorized by flag state to depart the port and carry additional liferafts until lifeboats are repair in two weeks) SOLAS 60, III/8
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Documentation
Issued 10 December 1996
Resolved
Provide onboard oil transfer procedures in the language of the crew and a complete fuel oil line diagram prior to bunker operations. _x001C_ _x001C_ 33 CFR 155.740
Condition: Unknown
Due 31 December 1996
Resolved 19 December 1996
Navigation
Issued 10 December 1996
Resolved
Provide onboard Coast Pilot prior to departure Port of Houston._x001C_ _x001C_ _x001C_ SOLAS 74, V/20
Condition: Unknown
Due 12 December 1996
Resolved 19 December 1996
Navigation
Issued 10 December 1996
Resolved
Repair and demonstrate proper operation of 2nd marine radar prior to departure Port of Houston. Provide service report to Coast Guard._x001C_ _x001C_ SOLAS 74 V/12
Condition: Unknown
Due 12 December 1996
Resolved 19 December 1996
Fire Fighting
Issued 21 December 1994
Resolved
VSL MUST PROVIDE ONE ADDITIONAL FIRE HOSE.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Deck/Cargo
Issued 24 March 1993
Resolved
OTP'S DID NOT CONTAIN THE PRODUCT INFORMATION FOR THE PRODUCTS TRANSFERED.
Condition: Unknown
Due 13 October 1993
Resolved 13 October 1993
Navigation
Issued 26 May 1987
Resolved
VSL DID NOT HAVE ON BOARD TWO INDEPENDENT OPERATING RADAR AS REQUIRED BY 33CFR164.37.
Condition: Unknown
Due 27 May 1987
Resolved 26 May 1987