Records from 1984 to 2024. Most recent: inspection, 8 February 2024.
Inspection history · 69
8 February 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7862599
5 January 2009
PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3388195
8 August 2008
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3292995
13 April 2008
ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3183313
5 October 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3073606
12 February 2007
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2880453
9 February 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2869990
2 October 2006
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2791548
10 April 2006
Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2620788
19 February 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2588314
6 February 2006
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2579777
12 December 2005
ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2549775
10 August 2005
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2458360
18 July 2005
Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2431739
6 June 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2381160
25 April 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2343120
28 January 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2282363
24 January 2005
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2279677
6 December 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2254453
17 September 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2198085
23 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2174180
19 July 2004
PII Safety Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2137952
19 July 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2138290
6 July 2004
ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2122872
26 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2054871
12 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2044014
1 March 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2015843
16 February 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2007782
2 February 2004
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1998550
1 September 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1893740
11 August 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1873494
22 July 2003
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1853237
16 July 2003
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1847910
28 May 2003
Administrative Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1804075
8 April 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1769847
8 April 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1770526
25 August 2002
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1668702
13 August 2002
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1660999
3 June 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1625720
15 February 2001
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 287243
4 March 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 275415
12 February 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 274773
6 July 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 430407
26 December 1998
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 424041
15 November 1998
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 422742
29 October 1998
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 33392
14 July 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 418032
2 December 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 410536
18 November 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 410164
21 February 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 388057
27 April 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 377763
3 March 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 648297
2 March 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 375790
14 July 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 368586
21 May 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 645334
20 May 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 367055
25 February 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 24478
7 January 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 355527
27 May 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 648294
12 May 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 351030
13 July 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 344960
21 May 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 344000
3 June 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 455752
1 September 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 332407
27 October 1988
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 326487
2 June 1986
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 309239
8 November 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 305267
25 October 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 304991
30 November 1984
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 470422
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 5 January 2009
Resolved
Oily water seperator onboard is currently not operating properly. The oil content meter will not read below 30 ppm. Class to provide report attesting to proper operation of ows/ocm and provide to sector miami.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2009
Resolved 10 January 2009
Resolution: Observed proper operation of the OWS working together in conjunction with the oil content meter and the solenoid valves.
Lifesaving › Launching Appliances › Winch
Issued 5 January 2009
Resolved
Launch and recovery rescue boat davit electrical motor in operable. Repair or replace motor and prove proper operation in presence of USCG inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2009
Resolved 10 January 2009
Resolution: Witnessed the successful launching and recovery of rescue boat.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 5 January 2009
Resolved
Provide/replace electrical outlets through out engine room.
Due 12 January 2009
Resolved 10 January 2009
Resolution: Observed replacement of electrical outlets throughout engine room.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 10 April 2006
Resolved
Interim Safety Equipment Cert had expired on 8 April 06. Vessel Agent had scheduled Class to come onboard the same day to conduct survey and issue a new certificate. Surveyor attend ship and issued a one month extension. Vessel is schedule to receive full term certificate upon next US port Arrival.
Due 10 April 2006
Resolved 10 April 2006
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 12 December 2005
Resolved
Vessel is not manned IAW the Safe Manning Certificate, missing second mate, provide second mate prior to sailing IAW SOLAS 74 Reg. V/14 (2004 ed.)
Action required: 705 - Other - as specified
Due 12 December 2005
Resolved 13 December 2005
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 12 December 2005
Resolved
All crew members are missing required medical certificates. Provide current medical certificates prior to sailing, IAW STCW I/9.
Action required: 705 - Other - as specified
Due 12 December 2005
Resolved 13 December 2005
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 12 December 2005
Resolved
Paint locker is being used for stowage of misc. materials, remove all non-paint supplies.
Action required: 705 - Other - as specified
Due 12 December 2005
Resolved 6 February 2006
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 12 December 2005
Resolved
Store paint located in fwd store room in the paint locker.
Action required: 705 - Other - as specified
Due 12 December 2005
Resolved 6 February 2006
Deck/Cargo › Cargo Stowage › General
Issued 12 December 2005
Resolved
Provide missing lashing equipment for cargo stowage as required by the cargo securing manual.
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 6 February 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 12 December 2005
Resolved
Water has accumulated in the fwd storage room pump water to an approved shoreside facility.
Action required: 705 - Other - as specified
Due 12 December 2005
Resolved 6 February 2006
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 12 December 2005
Resolved
STBD winch hydralic unit is leaking oil, replace or make proper repairs.
Action required: 705 - Other - as specified
Due 12 December 2005
Resolved 6 February 2006
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 12 December 2005
Resolved
Replace or renew the standard discharge connection.
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 6 February 2006
Fire Fighting › International Shore Connection › Connection
Issued 12 December 2005
Resolved
Replace the international shore connection.
Action required: 705 - Other - as specified
Due 19 December 2005
Resolved 6 February 2006
Operations/Management › Port and Waterways Safety › Notice of Hazardous Condition
Issued 12 December 2005
Resolved
Failure to provide immediate notification of a hazardous condition, vessel entered port without a second mate as required by the safe manning certificate.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2005
Resolved 12 December 2005
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 August 2005
Resolved
Vessel shall not use/operate oily water separater. All slops must be retained onboard until oily water separater is recalculated to 15 ppm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2005
Resolved 12 December 2005
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 19 July 2005
Resolved
Excessive oily water in bilge. O/W storage tank found 3/4 full. Properly dispose of oily water to an approved reception facility Provide proof of receipt to USCG via fax.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2005
Resolution: Received disposal reciept.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 July 2005
Resolved
Inspectors doubt the oily water seperator is operational and functions properly. Provide USCG with a flag state report attesting to the operational condition of the OWS.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 August 2005
Resolution: Provided report attesting to proper operation of OWS.
Construction/Loadline › Structures › Superstructure
Issued 19 July 2005
Resolved
Port side rescue boat launching station/ emergency embarkation station has no guard rails or means for protection oif the crew. Provide repair plan proposal to USCG for temorary repairs from the vessels class society
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2005
Resolution: Guard rails were installed on both the Port and Starboard emergency embarkation stations.
Personnel › Manning/Qualifications
Issued 22 July 2003
Resolved
Vessel is not manned IAW Safe Manning Document. Provide letter from flag state allowing a single voyage to Belize. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2003
Resolution: Letter from flag state is provided.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 22 July 2003
Resolved
Have flag state address Safe Manning Document. Current document requires an additional deck officer.
Action required: 15 - Rectify deficiencies by next port
Resolved 22 July 2003
Resolution: Flag state addressed issue and will provide additional deck officer.
Documentation › Certificates/Documents
Issued 16 July 2003
Resolved
Vessel's new Minimum Safe Manning certificate issued by Honduras is only good for 600 NM. Vessel normally travels from Belize to Port Everglades which is over a 700 NM voyage. Provide a new Safe Manning Certificate prior to next U.S. port. LEGACY COMPONENT DESC: Minimum Safe Manning Document
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 11 August 2003
Resolution: New Safe Manning Certificate faxed to MSO Miami.
Lifesaving › Inflatable Liferafts
Issued 3 June 2002
Resolved
PROVIDE SERVICE REPORTS FOR LIFERAFTS.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2002
Resolved 6 June 2002
Resolution: RECEIVED REPORT FROM MOBILE SHIP CHANDLERY INC. DATED 05JUN02 ATTESTING TO THE SERVICE AND TESTING OF ALL LIFERAFTS.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 3 June 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2002
Resolved 7 June 2002
Resolution: RECEIVED TECH. REPORT FROM R. CARTER AND ASSOCIATES DATED 05JUN02 ATTESTING TO THE SERVICING OF ALL FIRE EXTINGUISHERS ON BOARD.
Documentation › Safety/Response Plans/Programs
Issued 3 June 2002
Resolved
PROVIDE SOPEP TO INCLUDE LATEST CIRCULAR (6.7) LEGACY COMPONENT DESC: SOPEP
Due 17 June 2002
Resolved 13 August 2002
Documentation › Manuals/Policy Documentation
Issued 3 June 2002
Resolved
PROVIDE TRAINING MANUAL IN LANGUAGE UNDERSTOOD BY CREW. INCLUDE MISSING SECTIONS THAT REF. THE PARTICULAR GEAR FOUND ON BOARD. TRAINING MANUAL PROVIDED WAS CANNED VERSION. LEGACY COMPONENT DESC: Training Manual (lifesaving)
Due 17 June 2002
Resolved 13 August 2002
Documentation › Manuals/Policy Documentation
Issued 3 June 2002
Resolved
PROVIDE FIRE FIGHTING AND LIFE SAVING EQUIPMENT MAINTENANCE MANUAL. LEGACY COMPONENT DESC: Instructions for On-board Maintenance (lifesaving)
Due 17 June 2002
Resolved 13 August 2002
Documentation › Safety/Response Plans/Programs
Issued 3 June 2002
Resolved
PROVIDE UPDATED FIRE CONTROL PLAN TO INCLUDE USE OF INTERNATIONAL SYMBOLS. ENSURE CLASS "A" BOUNDRIES ARE IDENTIFIED. CURRENT FIRE PLAN IS OUTDATED AND DOES NOT CORRESPOND TO SHIP. LEGACY COMPONENT DESC: Fire Control Plans
Due 17 June 2002
Resolved 13 August 2002
Lifesaving › Launching Appliances
Issued 3 June 2002
Resolved
PROVE PROPER OPERATION OF STARBOARD LIFEBOAT DAVITS. LIFEBOAT UNABLE TO BE LAUNCHED. LEGACY COMPONENT DESC: Davit
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2002
Resolution: USCG WITNESSED SAT. OPERATION OF LIFEBOAT DAVIT
Communications › Radio Communications
Issued 3 June 2002
Resolved
SERVICE AND REGISTER SHIPS EPIRB. LEGACY COMPONENT DESC: Emergency Source of Power
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2002
Resolution: RCVD RPT FM NOAA SHOWING REGISTRATION OF EPIRB.
Fire Fighting
Issued 12 February 2000
Resolved
PRIOR TO 15MAR00 PROVDE MOST RECENT FIRE EXTINGUISHING SERVICE REPORT.
Condition: Unknown
Due 4 March 2000
Resolved 4 March 2000
Electrical
Issued 12 February 2000
Resolved
PRIOR TO 26FEB00 REPLACE LIGHT FIXTURE IN PAINT LOCKER WITH A INTRINSICALLYSAFE FIXTURE.
Condition: Unknown
Due 4 March 2000
Resolved 4 March 2000
Fire Fighting
Issued 12 February 2000
Resolved
PRIOR TO 26FEB00 REPLACE FIRE EXTINGUISHER IN PAINT LOCKER OUTSIDE SPACE.
Condition: Unknown
Due 4 March 2000
Resolved 4 March 2000
Lifesaving
Issued 15 November 1998
Resolved
Replace self-igniting smokes on starboard lifebuoy._x001C_ SOLAS
Condition: Unknown
Due 30 December 1998
Resolved 30 December 1998
Lifesaving
Issued 15 November 1998
Resolved
Replace waterlight on lifering located on aft cargo deck._x001C_ SOLAS
Condition: Unknown
Due 30 December 1998
Resolved 30 December 1998
Lifesaving
Issued 15 November 1998
Resolved
Provide retro-reflective tape on all lifejackets._x001C_ SOLAS 74 amended III/30.2.7
Condition: Unknown
Due 30 December 1998
Resolved 30 December 1998
Navigation
Issued 18 November 1997
Resolved
PRIOR TO 25 NOVEMBER 1997, PROVIDE UPDATED MANUEVERING FACT DIAGRAM AND WARNING STATEMENT FOR VESSEL.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Engineering
Issued 18 November 1997
Resolved
PRIOR TO 01 DECEMBER 1997, PROVE PROPER OPERATION OF OILY WATER SEPARATOR_x001C_ TO USCG MARINE INSPECTOR.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Deck/Cargo
Issued 18 November 1997
Resolved
MAINTAIN IN SLUDGE TANK ALL OILY WASTES UNTIL OWS APPROVED OF BY USCG MARINE INSPECTOR, OR PROVIDE RECEIPTS OF OILY WASTE DISCHARGE TO RECEPTION FACILITIES.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Engineering
Issued 18 November 1997
Resolved
PRIOR TO 25 NOVEMBER 1997, PROVIDE COMPLETE SET OF OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 18 November 1997
Resolved
HEAVING LINE ON PORT BRIDGE WING LIFEBUOY TIED IN TIGHT COIL. CORRECTED ONTHE SPOT.
Condition: Unknown
Due 18 November 1997
Resolved 20 November 1997
Fire Fighting
Issued 21 February 1996
Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE PROFESSIONAL SERVICE OF PORTABLE FIRE EXTINGUISHERS. _x001C_
Condition: Unknown
Due 29 March 1996
Resolved 17 April 1996
Fire Fighting
Issued 21 February 1996
Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE FIRE EQUIPMENT MAINTENANCE INSTRUCTION.
Condition: Unknown
Due 29 March 1996
Resolved 17 April 1996
Lifesaving
Issued 21 February 1996
Resolved
PRIOR TO NEXT U.S. PORT, UPDATE SOLAS TRAINING MANUAL FOR EQUIPMENT ONBOARD.
Condition: Unknown
Due 29 March 1996
Resolved 17 April 1996
Navigation
Issued 21 February 1996
Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE MEANS TO DETERMINE RUDDER ANGLE ON AFT RUDDER POST (VISIBLE).
Condition: Unknown
Due 29 March 1996
Resolved 17 April 1996
Fire Fighting
Issued 21 February 1996
Resolved
PRIOR TO NEXT U.S. PORT, SEPARATE FIRE OUTFITS.
Condition: Unknown
Due 29 March 1996
Resolved 17 April 1996
Fire Fighting
Issued 21 February 1996
Resolved
PRIOR TO NEXT U.S. PORT, UPDATE FIRE CONTROL PLAN.
Condition: Unknown
Due 29 March 1996
Resolved 17 April 1996
Documentation
Issued 2 March 1995
Resolved
VESSEL CARRIED SULFURIC ACID UN#1830 WITH NO CORRESPONDING ENTRY ON THE DANGEROUS CARGO MANIFEST.
Condition: Unknown
Due 2 March 1995
Resolved 2 March 1995
Documentation
Issued 2 March 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Construction/Loadline
Issued 20 May 1994
Resolved
The vessel's standard discharge connection did not meet the requirments in 33 CFR 155.430(a)(4) the flange is to have 6 slots, bolts and nuts, the vessel's only had 4.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Construction/Loadline
Issued 12 May 1992
Resolved
A violation of 46 CFR 42.15-10(a) in that the superstructure access doors could not be made weathertight due to open deck access doors had rust holesand loose dogs making them non weathertight. Vessel subject to U.S. regulations per 46 CFR 2.01-13(b).
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Documentation
Issued 12 May 1992
Resolved
Master had not signed last two pages of oil record book.
Condition: Unknown
Due 12 May 1992
Resolved 27 May 1992
Deck/Cargo
Issued 12 May 1992
Resolved
Vessel had one oxygen and two acetylene compressed gas cylinders making direct contact with the vessel deck and one another.
Condition: Unknown
Due 12 May 1992
Resolved 27 May 1992
Documentation
Issued 25 October 1985
Resolved
OIL TRANSFER PROCEDURES NOT COMPLETE 33 CFR 155.750
Condition: Unknown
Due 8 November 1985
Resolved 25 October 1985