Records from 1984 to 2005. Most recent: inspection, 24 May 2005.
Inspection history · 17
24 May 2005
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2366702
20 February 2004
Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2006277
20 February 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2010301
19 February 2003
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1746917
29 January 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 286464
20 February 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 274835
8 November 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 422414
20 July 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 418303
14 April 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 415437
11 December 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 787496
17 November 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 410106
29 July 1997
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 405916
13 February 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 375076
16 January 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 374175
10 July 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 317270
19 June 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 309473
7 September 1984
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 297784
Navigation › Piloting/Steering › Gyro Compass
Issued 20 February 2004
No resolution recorded
Vessel reported an inoperable gyrocompass and requested an LOD to enter and depart the port of Charleston, SC.
Due 20 February 2004 — due date passed with no resolution recorded
Lifesaving › Lifeboat › Propulsion Starting System
Issued 13 February 2004
Resolved
Starboard motor lifeboat did not start. Lifeboat needs to be started and run properely prior to departure from the Port of Charleston.
Condition: Unknown
Due 23 February 2004
Resolved 20 February 2004
Resolution: Prooved proper operation of Starboard lifeboat.
Electrical
Issued 29 January 2001
Resolved
VALVE ON S/W COOLING PIPE FOR #1 GENERATOR HOLED AND LEAKING (SOLAS 74A/I- 11)
Condition: Unknown
Due 2 February 2001
Resolved 2 February 2001
Engineering
Issued 29 January 2001
Resolved
F/W PIPE FOR AUXILLARY MACHINERY HOLED AND LEAKING. LOCATED IN ENGINE ROOM, STBD SIDE AFT, NEXT TO THE #1 GENERATOR (SOLAS 74A/I-11)
Condition: Unknown
Due 1 March 2001
Resolved 5 December 2002
Engineering
Issued 29 January 2001
Resolved
F/W PIPE LINE ABOVE AUXILLARY MACHINERY F/W COOLER HAS FOUR (04) SOFT PATCHES ON IT (SOLAS 74A/I-11)
Condition: Unknown
Due 1 March 2001
Resolved 5 December 2002
Electrical
Issued 29 January 2001
Resolved
"T" CONNECTION FOR S/W COOLING ON #2 AND #3 GENERATORS HOLED AND LEAKING (SOLAS 74A/I-11)
Condition: Unknown
Due 1 March 2001
Resolved 5 December 2002
Electrical
Issued 29 January 2001
Resolved
CLASS SOCIETY MUST ADDRESS AND APPROVE DRAIN APPARATUS' USED FOR LUBE OIL ON ALL GENERATORS (SOLAS 74A/I-11)
Condition: Unknown
Due 1 March 2001
Resolved 5 December 2002
Electrical
Issued 29 January 2001
Resolved
#2 GENRATOR HAS FUEL LEAKS ON #4 FUEL INJECTED FUSH ROD (SOLAS 74A/I-11)
Condition: Unknown
Due 2 February 2001
Resolved 2 February 2001
Unknown
Issued 29 July 1997
Resolved
PROVIDE DOCUMENTATION FROM CLASS STATING PERMANENT REPAIRS TO THE DOUBLERS ON THE #1 FIRE PUMP AND #1 GENERATOR COOLING WATER INTAKE LINE HAVE BEEN MADE BY 01 OCT 1997.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Fire Fighting
Issued 29 July 1997
Resolved
UPDATE FIRE CONTROL PLAN.
Condition: Unknown
Due 1 August 1997
Resolved 5 August 1997
Accommodation/Occupational Safety
Issued 29 July 1997
Resolved
REPAIR CREWS TOILETS AND SHOWERS AS NECESSARY.
Condition: Unknown
Due 1 August 1997
Resolved 5 August 1997
Lifesaving
Issued 29 July 1997
Resolved
FREE UP WATERTIGHT DOOR DOGS AND REPLACE RUBBER GASKETS AS NECESSARY.
Condition: Unknown
Due 1 August 1997
Resolved 5 August 1997
Lifesaving
Issued 29 July 1997
Resolved
REPLACE FLAME SCREENS ON FUEL TANK VENTS.
Condition: Unknown
Due 1 August 1997
Resolved 5 August 1997
Fire Fighting
Issued 29 July 1997
Resolved
SERVICE CO2 FIRE EXTINGUISHERS.
Condition: Unknown
Due 1 August 1997
Resolved 5 August 1997
Fire Fighting
Issued 29 July 1997
Resolved
SERVICE FIXED CO2 FIRE FIGHTING SYSTEM IN PAINT LOCKER.
Condition: Unknown
Due 1 August 1997
Resolved 5 August 1997
Lifesaving
Issued 29 July 1997
Resolved
REMOVE HAZMAT FROM BOSUN LOCKER AND STORE PROPERLY.
Condition: Unknown
Due 1 August 1997
Resolved 5 August 1997
Lifesaving
Issued 29 July 1997
Resolved
REPAIR LEAKING BALLAST AND FIRE PUMP.
Condition: Unknown
Due 1 August 1997
Resolved 5 August 1997
Navigation
Issued 13 February 1995
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE B/A LIGHT LIST VOL.J USED BY THE VSL WASNOT CORRECTED TO LATEST NTM WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS THAT WERE APPLICABLE TO THE VSL ROUTE FROM CAPE HENLOPEN DE TO CAMDEN N.J. CORRECT PRIOR TO DEPARTING PORT._x001C_
Condition: Unknown
Due 13 February 1995
Resolved 14 February 1995
Lifesaving
Issued 13 February 1995
Resolved
A DEFICIENCY UNDER SOLAS CH-III REG 7-1.3 IN THAT THE VESSEL IS REQUIRED 5 WORKING FLOAT LIGHTS. THE VESSEL ONLY HAD ONE WORK LIGHT AT THE TIME OF INSPECTION. CORRECT PRIOR TO DEPARTING PORT._x001C_ _x001C_
Condition: Unknown
Due 13 February 1995
Resolved 14 February 1995
Navigation
Issued 13 February 1995
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE VSL DID NOT HAVE O/B THE REQUIRED #8 SUPPLEMENT FOR THE B/A COAST PILOT VOL.69 ON BOARD OR ITS FOREIGN EQUIVALENT WHICH WAS REQUIRED FOR THE VSL'S ROUTE FROM CAPE HENLOPEN DE TO CAMDEN N.J. CORRECT PRIOR TO DEPARTING PORT._x001C_
Condition: Unknown
Due 13 February 1995
Resolved 14 February 1995
Navigation
Issued 13 February 1995
Resolved
A VIO OF 33 CFR 164.30 IN THAT B/A CHARTS 2563, 2564 USED BY THE VSL WERE NOT CORRECTED TO LATEST NTM WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM CAPE HENLOPEN DE TO CAMDEN N.J. CORRECT PRIOR TO DEPARTING PORT._x001C_
Condition: Unknown
Due 13 February 1995
Resolved 14 February 1995
Engineering
Issued 16 January 1995
Resolved
Permanently repair the overboard sea valve behind the O.W.S. in way of the cement box, prior to return to a U. S. port, per SOLAS Chpt II-1 Reg 26.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Engineering
Issued 16 January 1995
Resolved
Permanently repair the main engine cooling line (stbd side) in way of the concrete box, prior to return to a U. S. port, per SOLAS Chpt II-1 Reg 26.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Accommodation/Occupational Safety
Issued 16 January 1995
Resolved
Replace / repair the two air blowers on the vessel's MSD. The MSD is currently working with a bypass line from the ship's service air system. Complete prior to return to a U. S. port after Los Angeles & New Orleans. 33 CFR 159.17
Condition: Unknown
Due 16 February 1995
Resolved 19 January 1995
Engineering
Issued 16 January 1995
Resolved
The pipe seam on the auxiliary sea water line (behind the stbd, upper levelhydro tank) is wasting out. Renew line or make repairs as necessary. Complete prior to return to a U. S. port after Los Angeles and New Orleans.SOLAS Chpt II-1 Reg 26.
Condition: Unknown
Due 16 February 1995
Resolved 19 January 1995
Engineering
Issued 16 January 1995
Resolved
Repack or repair the aft lubricating oil pump for the main engine. The pump is leaking badly around the packing. Complete prior to departure per SOLAS Chpt II-2 Reg 2.
Condition: Unknown
Due 16 February 1995
Resolved 19 January 1995
Construction/Loadline
Issued 16 January 1995
Resolved
Six vent closures are frozen open. Repair as needed to allow them to close. (#1 crane base = 3, #2 crane base = 1, stern = 2) Complete prior todeparture per ICLL Chpt II Reg 19 (4).
Condition: Unknown
Due 16 January 1995
Resolved 19 January 1995
Engineering
Issued 16 January 1995
Resolved
Permanently repair the wasted discharge valve / line on the forward generator engine cooling pump in way of the concrete patch, prior to departure, per SOLAS Chpt II-1 Reg 26.
Condition: Unknown
Due 16 February 1995
Resolved 19 January 1995
Fire Fighting
Issued 16 January 1995
Resolved
Remove the hold back hook on the fire door between the engineroom and the steering gear space, prior to departure, per SOLAS Chpt II-2 Reg 47 (2).
Condition: Unknown
Due 16 February 1995
Resolved 19 January 1995
Lifesaving
Issued 16 January 1995
Resolved
Three of the four aft liferafts are mounted under a steel & fiberglass canopy. Remount the liferafts or remove the canopy as needed to allow the rafts to float free in the event of a sinking. Complete prior to departureper SOLAS Chpt III Reg 29.
Condition: Unknown
Due 16 February 1995
Resolved 19 January 1995
Documentation
Issued 7 September 1984
Resolved
VESSEL DID NOT HAVE AN IOPP CERTIFICATE ON BOARD.
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Documentation
Issued 7 September 1984
Resolved
VESSEL DOES NOT HAVE A PLACARD OF CORRECT SIZE/LOCATION
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984