AUTUMN is a 1978 freight ship. The Coast Guard has recorded 29 inspections since 1985, most recently in March 2006, along with 27 deficiencies and 6 operational controls, 1 with no removal date recorded.

Records from 1985 to 2006. Most recent: operational control imposed, 25 March 2006.

Built
1978
Last inspected
25 March 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7618301 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225948
Flag
MALTA
—
Maury page id
psix-225948

Inspections, by type

…with no type recorded20
Years with a record 16 calendar years (1985–2006)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it10648 - Convention (Subpart B), Net Ton
37339 - Displacement, Ton
29462 - Dead Weight, Ton
18374 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

25 March 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2609558
4 November 2005 NPV Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2530306
30 September 2005 MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · Deficiency Check · MARPOL Annex I Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2504140
19 August 2005 ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · Deficiency Check · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2467121
11 February 2005 MARPOL Annex I Examination · ISPS II Exam · NPV Safety Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2290558
23 January 2005 PII Safety Exam · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2279429
19 May 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2072521
18 May 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2073734
26 December 2003 Re-Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1964203
13 March 2003 Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1756733
26 February 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1750005
14 April 2002 In-Service Inspection · Administrative Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1604455
1 November 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 295208
23 November 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 422818
20 February 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 413152
27 August 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 382098
3 March 1993 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 537200
20 August 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 345406
6 January 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 341147
19 June 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 337776
15 December 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 458090
14 June 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 330659
7 May 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 323126
11 March 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 314773
25 October 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 457772
5 June 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 499748
12 April 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 307885
21 November 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 482051
10 March 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 300558

Deficiency record · 27

Engineering › Diesel Engine (propulsion-electric) › Valve
Issued 30 September 2005 Resolved
The No.2 diesel engine generator salt water cooling supply line has a temporary band clamp patch. Permanently repair to the satisfaction of class.
Action required: 705 - Other - as specified
Due 5 December 2005
Resolved 13 December 2005
Resolution: Received Class Report from ABS satisfying the requirement.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 19 August 2005 Resolved
The hatch cover combings on the Marine Sanitation Device are rusted and unable to close. Repair hatch cover combings to the satisfaction of Coast Guard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 30 September 2005
Resolution: The hatch cover combings were repaired to the satisfaction of the Coast Guard Inspector.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 19 August 2005 Resolved
The Marine Sanitation Device has a 1 inch hole on side plate. Repair side plate to the satisfaction of the Coast Guard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 30 September 2005
Resolution: The 1 inch hole on the side plate was repaired to the satisfaction of the Coast Guard Inspector.
Engineering › Diesel Engine (propulsion-electric) › Valve
Issued 19 August 2005 Resolved
The No.2 diesel engine generator salt water cooling supply line has a temporary band clamp patch. Permanently repair to the satisfaction of class.
Action required: 705 - Other - as specified
Due 19 September 2005
Resolved 30 September 2005
Resolution: Deficiency extended until 14 October 2005. See NEWMS Activity #2504140.
Operations/Management › Ballast Water Managment › Training
Issued 11 February 2005 Resolved
Vessel does not have a Ballast Water Management Plan onboard. Request vessel provide a Ballast Water Management Plan on board that was developed specifically for the vessel prior to next U. S. Port
Action required: 15 - Rectify deficiencies by next port
Resolved 19 August 2005
Resolution: The boarding team observed the Ballast Water Management Plan on board in order.
Lifesaving › Launching Appliances › Winch Brake
Issued 23 January 2005 Resolved
Gravity brake did not function properly
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2005
Resolution: Gravity brake functions properly
Navigation › Collision/Grounding Avoidance › Radar
Issued 21 December 2003 Resolved
PRIMARY AND SECONDARY RADARS WERE INOPERABLE WHEN VESSEL ENTERED PORT. LETTER OF DEVIATION WAS ISSUED. BOTH RADARS WERE REPAIRED INPORT AND VESSEL WAS ALLOWED TO DEPART.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 26 December 2003
Resolved 26 December 2003
Resolution: RADAR TECHS ATTENDED VESSEL AND CONDUCTED REPAIRS TO RADARS. VESSEL WAS ALLOWED TO DEPART THE PORT OF BROWNSVILLE.
Engineering › Lubricating Oil Service System
Issued 26 February 2003 Resolved
Temporary rubber hose is installed on lube oil storage tank fill line. Re-install as per original design to the satisfaction of classification society. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 12 March 2003
Resolved 11 March 2003
Resolution: Hose was removed and a new pipe was installed, as per system design.
Engineering › Sea-water System (primary cooling)
Issued 26 February 2003 Resolved
Temporary patches installed on the seawater cooling piping for refrigeration system located on the starboard side of the engine room. Repair or replace to the satisfaction of classification society. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 16 March 2003
Resolved 12 March 2003
Resolution: Pipe was renewed as necessary and found in good operating order.
Pollution Prevention/Response › Prevention Equipment
Issued 26 February 2003 Resolved
Sewage treatment tank is leaking from the bottom plating. Repair to the satisfaction of the Coast Guard. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Unknown
Due 12 March 2003
Resolved 11 March 2003
Resolution: An insert of approximately 8" x 12" was installed and sewage tank is in good operating conditions with no leaks noted.
Pollution Prevention/Response › Prevention Equipment
Issued 26 February 2003 Resolved
Sewage treatment plant piping has numerous patches installed that are leaking. Repair or replace to the satisfaction of classification society. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Unknown
Due 12 March 2003
Resolved 11 March 2003
Resolution: Piping was completely renewed and tested, test satisfactory.
Electrical › Lighting (service)
Issued 26 February 2003 Resolved
Properly rewire light fixtures and install diffusers for main diesel engine lubricating cylinder liner indicators. LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Due 6 March 2003
Resolved 11 March 2003
Resolution: Electrical wires and diffussers for main diesel engine lubricating cylinder indicators were properly installed and in good working condition.
Electrical › Lighting (service)
Issued 26 February 2003 Resolved
Light fixture in pantry has exposed electrical wires. Repair and replace electrical cover as per original design to the satisfaction of classification society. LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Due 6 March 2003
Resolved 11 March 2003
Resolution: Light fixture cover were installed.
Deck/Cargo
Issued 1 November 2001 Resolved
HYDRAULIC RAM TO #4 CARGO HOLD HATCH COVER JACK (STBD SIDE) LEAKING EXCESSIVELY, CONTAINMENT HAS EXCESS HYDRAULIC FLUID (SOLAS 74A REG. I/11). CLEAN UP EXCESS PRODUCT AND MAKE PERMANENT REPAIRS TO SATISFACTION OF CLASS.
Condition: Unknown
Due 8 November 2001
Resolved 14 April 2002
Resolution: Recieved class report attesting to the Hydraulic ram to #4 cargo hold hatch cover being fixed.
Documentation
Issued 1 November 2001 Resolved
VESSEL MISSING OIL TRANSFER PROCEDURES (33 CFR 155.720). PROVIDE TRANSFER PROCEDURES PRIOR TO NEXT BUNKERING OPERATION AND/OR PRIOR TO NEXT U.S PORT.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Documentation
Issued 23 November 1998 Resolved
Provide Oil Transfer Procedures in accordance with 33 CFR 155.750. Correctprior to next U.S. Port.
Condition: Unknown
Due 2 November 2001
Resolved 2 November 2001
Lifesaving
Issued 23 November 1998 Resolved
Remove gear from blocking emergency engine room exit. SOLAS 60 II/68. _x001C_ Correct prior to next U.S. Port.
Condition: Unknown
Due 2 November 2001
Resolved 2 November 2001
Fire Fighting
Issued 23 November 1998 Resolved
Make the fire doors to the engine room self closing. SOLAS 60 II/38. Correct prior to next U.S. Port.
Condition: Unknown
Due 2 November 2001
Resolved 2 November 2001
Construction/Loadline
Issued 23 November 1998 Resolved
Make permanent repairs to inboard side of sea chest where patched, lower engine room, stbd side. SOLAS 60 I/11. Provide class report prior to departure.
Condition: Unknown
Due 24 November 1998
Resolved 23 November 1998
Construction/Loadline
Issued 23 November 1998 Resolved
Make permanent repairs to pipes where patched on the #5 ballast to manifoldand the sea water to generator cooling line after the pump, stbd side lowerengine room. SOLAS 60 I/11. Provide class report prior to departure.
Condition: Unknown
Due 24 November 1998
Resolved 23 November 1998
Documentation
Issued 27 August 1995 Resolved
The M/V AUTUMN was in violation of SOLAS V, regulation 13 due to insufficient manning. The third mate required by the Safe Manning Certificate was unlicensed. In addition, the chief engineer's license expired on 22 May 1995.
Condition: Unknown
Due 28 August 1995
Resolved 28 August 1995
Navigation
Issued 27 August 1995 Resolved
Properly connect the storage tank with permanent piping as required by SOLAS II-1, regulation 29.12.3.
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Navigation
Issued 19 June 1990 Resolved
CHART NO. 18521 NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 19 June 1990
Resolved 19 June 1990
Navigation
Issued 19 June 1990 Resolved
CHART NO. 18523 NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 19 June 1990
Resolved 19 June 1990
Navigation
Issued 19 June 1990 Resolved
CHART NO. 18524 NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 19 June 1990
Resolved 19 June 1990
Navigation
Issued 19 June 1990 Resolved
U.S. COAST PILOT NOT CURRENTLY CORRECTED FOR AREA TRANSITED.
Condition: Unknown
Due 19 June 1990
Resolved 19 June 1990
Documentation
Issued 19 June 1990 Resolved
INTERNATIONAL OIL POLUTION PREVENTION CERTIFICATE MISSING SUPPLEMENT _x001C_ (FORM A).
Condition: Unknown
Due 19 June 1990
Resolved 19 June 1990

Ownership record