Records from 1985 to 1991. Most recent: inspection, 30 October 1991.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 6
30 October 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 439132
19 September 1991
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308190
18 June 1987
Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1311978
30 September 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 457622
1 May 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 983317
24 April 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 301774
Deck/Cargo
Issued 19 September 1991
Resolved
INSTALL PLUGS OF A MECHANICAL MEANS IN ALL SCUPPERS AND CARGO CONTAINMENT.
Condition: Unknown
Due 13 October 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 19 September 1991
Resolved
PROVIDE COMPLETE AND APPROPRIATE OIL TRANSFER PROCEDURES IN ACCORDANCE WITH33 CFR 155.750.
Condition: Unknown
Due 13 October 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 19 September 1991
Resolved
PROVIDE ONBOARD REQUIRED CHARTS FOR MISSISSIPPI RIVER PRIOR TO DEPARTURE FROM OR WITHIN NEW ORLEANS.
Condition: Unknown
Due 23 September 1991
Resolved 23 September 1991
Fire Fighting
Issued 19 September 1991
Resolved
MAKE PERMENANT REPAIRS TO PRESSURE CONTROL TUBING OF EMERGENCY FIRE PUMP.
Condition: Unknown
Due 23 September 1991
Resolved 23 September 1991
Deck/Cargo
Issued 19 September 1991
Resolved
MAKE PERMANENT REPAIRS TO STEAM LINE AT PUMPROOM BULKHEAD.
Condition: Unknown
Due 13 October 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 18 June 1987
Resolved
FIBER GLASS BUTTERWORTH PLATES.BUTTERWORTH OPENING ARE TOBE MADE OF CLASS AMATERIAL, STEEL OR AN EQUIVALENT MATERIAL CAPABLE OF WITH STANDING A 60MIN.BURN TEST.THIS IS THE U.S COAST GUARD POLICY FOR ALL TANK VESSEL.REF.SOLAS 1974,AMEND.1981,CHAPTERII-2,REG58.&46CFR 32.57.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Electrical
Issued 24 April 1985
Resolved
RESECURE ALL LOOSE LIGHT FIXTURE GLOBES IN CARGO PIMP ROOM IONSURING A PROPER FLAMETIGHT ( EXPLOSION PROOF) FIT.
Condition: Unknown
Due 24 April 1985
Resolved 24 April 1985
Deck/Cargo
Issued 24 April 1985
Resolved
ULLLAGE HOLES NOT FITTED WITH FLAME SCREENS WHILE OPEN DURING TRANSFER OPERATIONS. A VIOLATION OF 46CFR 35.30-10 / 46USC 39/A.
Condition: Unknown
Due 24 April 1985
Resolved 24 April 1985
Electrical
Issued 24 April 1985
Resolved
REMOVE OR REPAIR INOPERATIVE LIGHT FIXURE IN CARGO PUMP ROOM.
Condition: Unknown
Due 24 April 1985
Resolved 24 April 1985
Deck/Cargo
Issued 24 April 1985
Resolved
PERMANENTLY REPAIR VALVE LOCATED ON NO. 4 CARGO FILL LINE ( PORTSIDE OUT- BOARD).
Condition: Unknown
Due 24 April 1985
Resolved 24 April 1985
Deck/Cargo
Issued 24 April 1985
Resolved
RENEW OR REPAIR ALL FLAMES SCREENS WHEREVER NEEDED
Condition: Unknown
Due 24 April 1985
Resolved 24 April 1985