MAURY USCG vessel records Sign in
← All vessels

LINA

LINA is a 1978 freight ship. The Coast Guard has recorded 60 inspections since 1985, most recently in March 2007, along with 113 deficiencies and 8 operational controls.

Records from 1985 to 2007. Most recent: inspection, 5 March 2007.

Built
1978
Last inspected
5 March 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7622766 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226005
Flag
GREECE
—
Maury page id
psix-226005

Inspections, by type

…with no type recorded37
Years with a record 21 calendar years (1985–2007)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it8543 - Convention (Subpart B), Net Ton
27358 - Dead Weight, Ton
43879 - Displacement, Ton
17819 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 60

5 March 2007 MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2882166
18 October 2006 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2803147
2 October 2006 MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2791120
19 August 2006 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2751904
21 October 2005 ISPS II Exam · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2519354
23 August 2005 ISPS II Exam · Deficiency Check · PI Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2471790
22 June 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2399313
11 June 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2388734
10 June 2005 MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PI Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2385002
12 April 2005 ISM Exam · MARPOL Annex V Examination · STCW 95 Exam · Ballast Water Examination · Loadline Exam · MARPOL Annex I Examination · ISPS I Exam · PI Safety Exam · ILO-147 Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2331856
6 April 2005 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2327914
30 March 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2322856
15 March 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2310327
13 March 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2309034
9 February 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2289164
8 February 2005 Deficiency Check · ISM Exam · Ballast Water Examination · PI Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2288977
3 January 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2268103
1 January 2005 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2267123
17 July 2004 NPV Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2148027
14 July 2004 NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2132787
13 July 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2131319
13 July 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2132173
21 June 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2106004
15 April 2004 Annual Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2044460
13 November 2003 Re-Inspection · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1947099
27 June 2003 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1828227
25 April 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1780642
9 August 2002 Ballast Water Examination · Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1659099
26 June 2002 Re-Inspection · Ballast Water Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1637187
28 March 2002 Deficiency Check · Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1598800
2 November 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 295210
4 September 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 293368
25 July 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 291883
30 October 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 283827
30 October 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 285172
17 April 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 276978
17 April 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 277308
23 September 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 433218
22 March 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 426860
22 January 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 424814
16 July 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 418033
27 October 1997 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 409201
2 April 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 401928
8 April 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 389642
18 October 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 371447
18 October 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 863267
14 June 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 367439
18 March 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 647468
16 March 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 447213
3 November 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 467109
5 April 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 357358
28 February 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 349136
8 July 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 338050
27 March 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 329372
18 May 1988 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 323283
2 November 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 439295
26 May 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 316454
20 September 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 482802
5 May 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 308559
17 January 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 299950

Deficiency record · 113

Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 2 October 2006 Resolved
The Auxiliary engine inlet water cooling pipe has a temporary patch near the No. 1 pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 October 2006
Resolved 18 October 2006
Resolution: Received class report satisfying requirement.
Fire Fighting › Fire Main › Material
Issued 2 October 2006 Resolved
The inlet pipe for the fire pump between the strainer and pump has a temporary patch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 October 2006
Resolved 18 October 2006
Resolution: Received class report satisfying requirement.
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 2 October 2006 Resolved
The No. 3 auxiliary engine has a temporary patch on the fresh water cooling pipe for the turbo charger.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 October 2006
Resolved 18 October 2006
Resolution: Received class report satisfying requirement.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 23 August 2005 Resolved
02 inlet pipes to type II MSD wasted, 01 holed and leaking.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 21 October 2005
Resolution: Recieved class report.
Engineering › Freshwater Generation System › Piping
Issued 23 August 2005 Resolved
Freshwater pipe to vessel's accommodation spaces wasted.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 21 October 2005
Resolution: Recieved class report.
Lifesaving › Launching Appliances › Davit
Issued 23 August 2005 Resolved
Limit switch for port life boat is inoperable.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 21 October 2005
Resolution: Recieved class report.
Fire Fighting › Nozzles › Type
Issued 23 August 2005 Resolved
Improper nozzles in deck boxes. Design not of dual purpose and incorporated shut off device.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 21 October 2005
Resolution: Recieved class report.
Deck/Cargo › Cargo Stowage › General
Issued 10 June 2005 Resolved
Make repairs to fractured brackets at the forward starboard cargo holds #4 and 5.
Action required: 705 - Other - as specified
Due 10 July 2005
Resolved 10 June 2005
Deck/Cargo › Cargo Stowage › General
Issued 10 June 2005 Resolved
Properly stow acetylene bottles forward of #4 cargo hold. Must be corrected to the satisfaction of class or flag state.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 June 2005 Resolved
Provide evidence of current service for fixed fire fighting system in paint locker and engine room. Also provide evidence of current service of all portable fire extinguishers and SCBA's. Must be corrected to the satisfaction of class or flag state.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2005
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 10 June 2005 Resolved
Make repairs to paint locker mushroom vent.
Due 10 July 2005
Resolved 10 June 2005
Electrical › Electric Generation Source (service) › Generator
Issued 10 June 2005 Resolved
Make repairs and prove proper operation of #1 diesel generator.
Action required: 705 - Other - as specified
Due 4 January 2006
Resolved 24 August 2005
Resolution: Received class report.
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 10 June 2005 Resolved
Prior to it's use, restore auxiliary boiler safety valve hand reliefs. Must be corrected to the satisfaction of class or flag state.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2005
Fire Fighting › Fire Pumps › Pressure
Issued 10 June 2005 Resolved
Make repairs and prove proper operation of emergency fire pump. Must be corrected to the satisfaction of class or flag state.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2005
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 10 June 2005 Resolved
Renew all forward and port aft mooring lines. Must be corrected to the satisfaction of class or flag state.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 August 2005
Resolution: Received class report.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 10 June 2005 Resolved
Provide oil transfer procedures as required by 33CFR155.720. Must be corrected prior to transfer operations.
Action required: 705 - Other - as specified
Resolved 24 August 2005
Resolution: Received class report.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 10 June 2005 Resolved
Provide emergency steering gear instructions on bridge detailing procedures to be followed for bridge personnel.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 June 2005
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 10 June 2005 Resolved
Repair or replace all toilets on vessel as needed.
Due 10 July 2005
Resolved 24 August 2005
Resolution: Received class report.
Documentation › Logs/Records › Enhanced Survey Report File
Issued 10 June 2005 Resolved
Provide class survey report from inspection completed on 08JUN05.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2005
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 10 June 2005 Resolved
Update maneuvering fact sheet to reflect loaded and ballasted conditions and place required warning statement on sheet. Must be corrected to the satisfaction of class or flag state.
Due 10 July 2005
Resolved 10 June 2005
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 10 June 2005 Resolved
The substantial non-compliance and reasonably preventable deficiencies or situations that resulted in the detention and other deficiencies is evidence that the SMS is not properly implemented. Issued requirement for an external ISM audit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2005
Personnel › Certificates/Documents/Licenses › License, Master
Issued 12 April 2005 Resolved
Vessels master does not have proper endorsement for Ukraine Masters/GMDSS license. Masters ST. Vincent and the Grenadines endorsement references old Ukraine license [withheld]/1994. Master must prove proper ST. Vincent and the Grenadines endorsement prior to vessel departing the port of Savannah.
Action required: 705 - Other - as specified
Due 12 April 2005
Resolved 21 April 2005
Resolution: Received fax copy of application from Master to Flag State to have GMDSS endorsement issued with the serial number of new Certificate of Competency.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 April 2005 Resolved
During CG inspection the three-way shutoff valve on the oily water separator malfunctioned and froze in the closed position. Chief Engineer could not repair before completion of inspection. Vessel must prove proper operation of three-way valve prior to departure.
Action required: 705 - Other - as specified
Due 12 April 2005
Resolved 21 April 2005
Resolution: Inspection of OWS found that the three way shut-off valve had been replaced and in good working condition.
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 9 February 2005 Resolved
The dampeners for all of the power and natural air vents leading into the accommodation are sized and cannot be closed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2005
Resolved 18 February 2005
Resolution: Corrected to the satisfaction of the attending Classification Representative.
Fire Fighting › Ventilation Systems › Ducts
Issued 9 February 2005 Resolved
The fire dampeners for the supply and exhaust vents cannot be closed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2005
Resolved 18 February 2005
Resolution: These were repaired to the satisfaction of the attending Classification Society Representative.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 9 February 2005 Resolved
The skylights for the engine room cannot be closed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 14 February 2005
Resolution: Corrected by the crew. Witnessed operation of the skylights with the Classification Representative.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 9 February 2005 Resolved
Both fire suits have holes in them.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2005
Resolved 14 February 2005
Resolution: New fire suits were placed on board. Inspected these with the Classification Representative.
Fire Fighting › Ventilation Systems › Fans
Issued 9 February 2005 Resolved
The power supply vent for the steering flat is holed below the damper.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 14 February 2005
Resolution: Crew removed the holed section of the vent and inserted a new piece. Inspected this with the Classification Representative.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 9 February 2005 Resolved
The self-closing devices for the fire doors leading into the galley are missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 18 February 2005
Resolution: These were repaired to the satisfaction of the attending Classification Society Representative.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 9 February 2005 Resolved
The self closing devices for the engine room doors are missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 18 February 2005
Resolution: Repaired under the direction of the Classification Society Representative.
Construction/Loadline › Structures › Scuttle
Issued 9 February 2005 Resolved
Several of the dead light covers are missing from the crew cabins below the main deck scuttles. The Classification Society Representative issued a condition of class for these to corrected by 3/16/05
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2005
Resolved 15 March 2005
Resolution: All dead light covers have been put in place and secured.
Stability › Watertight Integrity › General
Issued 9 February 2005 Resolved
The Starboard Top Side Wing Tank has an approximate 1/2 inch hole in it, which is leaking into the engine room.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 14 February 2005
Resolution: The crew removed the wasted section of metal and inserted a new piece. Inspected this with the Classification Representative.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 9 February 2005 Resolved
All of the cargo holds are missing several hatch securing devices. Those that are there are approximately 80% wasted. Number one cargo hold hatch cover is leaking in two places. The Classification Society issued a condition of class for these to be corrected by 3/16/05
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2005
Resolved 24 August 2005
Resolution: Received class report.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 9 February 2005 Resolved
The sewage system is not being utilized. The crew has not been following the manufacturer’s requirements for maintenance of the system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2005
Resolved 18 February 2005
Resolution: The Classification Society Representative issued a non-conformity on this. It was corrected under the direction of the Classification Representative.
Fire Fighting › Ventilation Systems › Fans
Issued 9 February 2005 Resolved
The fire dampers for the vents on top of the mast houses cannot be closed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 14 February 2005
Resolution: The owners superintendent and crew inspected and repaired all of the vents. All of the dampers were in the closed position.
Stability › Watertight Integrity › General
Issued 9 February 2005 Resolved
The starboard anchor chain locker is missing its hatch cover.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 14 February 2005
Resolution: The hatch cover was found and reinstalled by the crew. Inspected this with the Classification Representative.
Stability › Watertight Integrity › General
Issued 9 February 2005 Resolved
The after peak tank top cover is missing all but two bolts. Suspect the cover was never secured while underway.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 15 February 2005
Resolution: Addressed by Class during ISM audit.
Stability › Watertight Integrity › General
Issued 9 February 2005 Resolved
The port anchor hatch is not being secured while underway.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 15 February 2005
Resolution: Addressed by the Classification Representative during the ISM audit.
Stability › Watertight Integrity › General
Issued 9 February 2005 Resolved
The forward peak tank was not being properly secured while underway.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 15 February 2005
Resolution: This was addressed by the Classification Representative during the ISM audit.
Fire Fighting › Fire Pumps › Casing
Issued 9 February 2005 Resolved
The emergency fire pump has a water leak on the head gasket
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 14 February 2005
Resolution: The crew replaced the head gasket.
Electrical › Electric Supply System (service) › Cable
Issued 9 February 2005 Resolved
The main electrical conduit line located on the main deck is wasted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 14 February 2005
Resolution: The crew has installed sheet metal over the wasted areas of the conduit line. Inspected this with the Classification Representative.
Engineering › Steering Gear System › Pump
Issued 9 February 2005 Resolved
There is a leak around the port hydraulic reservoir low oil sensor unit.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 14 February 2005
Resolution: The crew replaced the gasket around the sensor. Inspected this with the Classification Representative.
Construction/Loadline › Penetrations › Pipe Flange
Issued 9 February 2005 Resolved
The port sewage overboard valve is leaking. There is a small hole in the body of the valve opposite the valve stem, which when secured would not stop the water from entering the engine room. A Condition of Class was issued corrective action must be completed by 3/16/05.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2005
Resolved 15 March 2005
Resolution: An approved Classification Valve has been installed by the crew.
Engineering › Fuel Oil Service System › Tank
Issued 9 February 2005 Resolved
The heavy fuel oil service tank has a crack in it.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 14 February 2005
Resolution: The metal sheeting on the outside of the tank was removed by the crew. The tank was found in good condition. Cause was due to the crew overfilling the tank. The oiled soaked insulation was removed. This was inspected with by the Classification Rep.
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 9 February 2005 Resolved
The lower port side crew shower room deck is wasted. The water from the shower is leaking into the engine room. The Classification Society Representative issued a condition of class on this. This must be corrected by 3/16/05
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2006
Resolved 24 August 2005
Resolution: Received class report.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 9 February 2005 Resolved
The meat locker locking mechanism is broken. The crew has made a jury rigged system, which if not closely monitored someone could accidentally be locked inside the freezer. ILO 147.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 14 February 2005
Resolution: The Lock has been repaired by the crew.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 9 February 2005 Resolved
The door framing around the aft accommodation doors is wasted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 14 February 2005
Resolution: New door framing was replaced by the crew. This was inspected by the Classification Representative.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 9 February 2005 Resolved
The engine room workshop is in disarray. There are numerous lights without covers, over sized lamps, open containers of flammable cleaning fluids near the welding area, excess cans of open and close paint cans, missing safety guards for the grinder and there are or safety goggles for the crew to wear when operating the lathe or grinder. ILO 147
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 14 February 2005
Resolution: The crew has installed new lights, removed all paint cans and open oil containers. New safety guards were installed on the grinder. This was inspected by the Classification Representative.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 February 2005 Resolved
Throughout the vessel there a number of lights that are missing there covers, oversized lamps or the fixtures are broken.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 14 February 2005
Resolution: The crew has installed new lights with covers in all areas of the vessel. These were inspected by the Classification Representative.
Operations/Management › Ballast Water Managment › Ballast Exchange
Issued 9 February 2005 Resolved
The ship does not have a Ballast Water Management Plan.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 15 February 2005
Resolution: A copy of the plan was placed on board by the company DPA.
Personnel › Training › Fire Fighting Basic
Issued 9 February 2005 Resolved
The crew failed two fire drills.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 14 February 2005
Resolution: Successfully conducted a fire drill in the presence of the Classification representative.
Personnel › Training › Lifeboatman
Issued 9 February 2005 Resolved
The crew failed two lifeboat drills. The Master changed the launching instructions for the lifeboats without authorization. The Classification Society issued a condition of class that requires the launching and embarkation appliances should be completed in accordance with SOLAS-74 Manual not later than 3/16/05.
Action required: 705 - Other - as specified
Due 16 March 2005
Resolved 15 March 2005
Resolution: Lifeboat instructions have been changed and approved by the Classification Society.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 9 February 2005 Resolved
The OCMI / COPT questions the validity of the vessel's safety management certificate. Based upon the listed above objective evidence an external ISM audit must be conducted prior to the vessel's departure from San Francisco Bay.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2005
Resolved 18 February 2005
Resolution: The ISM audit was conducted on 2/15/05. The report and its finding were received by this unit on 2/18/05.
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 January 2005 Resolved
Spool piece for sewage OVBD on STBD side is wasted and weeping, compromising the vessel's watertight integrity.
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 10 January 2005
Resolution: Survey, audit and reports conducted by Flag State representative and witnessed by U.S. Coast Guard Marine Inspector.
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 January 2005 Resolved
Spool piece for boiler blow-down on STBD side is wasted and weeping, compromising the vessel's watertight integrity.
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 10 January 2005
Resolution: Survey, audit and reports conducted by Flag State representative and witnessed by U.S. Coast Guard Marine Inspector.
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 January 2005 Resolved
Spool piece for sewage OVBD on Port side is wasted and weeping, compromising the vessel's watertight integrity.
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 10 January 2005
Resolution: Survey, audit and reports conducted by Flag State representative and witnessed by U.S. Coast Guard Marine Inspector.
Construction/Loadline › Hull › Hull Plating
Issued 3 January 2005 Resolved
Hull plating at spool piece for S/W OVBD for F/W generator, has a clad weld on the hull and appears wasted and weeping, compromising the vessel's watertight integrity.
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 10 January 2005
Resolution: Survey, audit and reports conducted by Flag State representative and witnessed by U.S. Coast Guard Marine Inspector.
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 January 2005 Resolved
S/W discharge pipe for SSDG located before isolation valve is wasted, holed and leaking, compromising the vessel's watertight integrity and the ability to operate the SSDGs.
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 10 January 2005
Resolution: Survey, audit and reports conducted by Flag State representative and witnessed by U.S. Coast Guard Marine Inspector.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 3 January 2005 Resolved
Entire sewage piping system located in engine room; (inlet pipes, discharge pipes and transfer pipes) are holed, wasted and weeping in multiple locations, creating an unsanitary condition in the vicinity of the piping system.
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 10 January 2005
Resolution: Survey, audit and reports conducted by Flag State representative and witnessed by U.S. Coast Guard Marine Inspector.
Fire Fighting › Fire Main › Condition
Issued 3 January 2005 Resolved
Fire Main discharge pipe located lower level fwd. E/R has a temporary repair (doubler) on the pipe.
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 10 January 2005
Resolution: Survey, audit and reports conducted by Flag State representative and witnessed by U.S. Coast Guard Marine Inspector.
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 January 2005 Resolved
#3 SSDG S/W inlet and discharge pipes to air box cooler have temp. repairs (soft patches) that are weeping, compromising the safe operation of the generator.
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 10 January 2005
Resolution: Survey, audit and reports conducted by Flag State representative and witnessed by U.S. Coast Guard Marine Inspector.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 3 January 2005 Resolved
Vessel's line-throwing charges are expired. All four to be replaced.
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 10 January 2005
Resolution: Survey, audit and reports conducted by Flag State representative and witnessed by U.S. Coast Guard Marine Inspector.
Construction/Loadline › Hull › Hull Plating
Issued 3 January 2005 Resolved
Excessive wastage and pitting identified in the following areas to be properly cleaned to bare metal and gauged and compared with original scantlings: -Hull and spool piece in way of STBD side sewage OVBD, -Hull and spool piece in way of STBD side boiler blow-down OVBD, -Hull and spool piece in way of STBD side steam condensate OVBD, -Hull under S/W OVBD for A/C condensate from engine control,
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 10 January 2005
Resolution: Survey, audit and reports conducted by Flag State representative and witnessed by U.S. Coast Guard Marine Inspector.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 3 January 2005 Resolved
Vessel does not have sufficient food on board to feed the crew for more than 2 days. A variety of food provisions to be purchased prior to departure.
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 4 January 2005
Resolution: Food and provisions received.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 3 January 2005 Resolved
Due to multiple deficiencies and the lack of non-conformities addressing the discrepancies, an external audit of the Safety Management System by a Recognized Organization is required. The ISM audit is to be conducted to the satisfaction of the Flag State Administration and the U.S. Coast Guard Activities Baltimore prior to the departure from the Port of Baltimore.
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 10 January 2005
Resolution: Survey, audit and reports conducted by Flag State representative and witnessed by U.S. Coast Guard Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 July 2004 Resolved
Repair or replace damaged rail on forecastle by 17 July to satisfaction of local PSCO.
Condition: Improper/Lack of Maintenance
Due 17 July 2004
Resolved 17 July 2004
Resolution: Repairs visually inspected and found satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 July 2004 Resolved
Repair or replace all rails and steps that are wasted to the satisfaction of local PSCO by 17 July.
Condition: Improper/Lack of Maintenance
Due 17 July 2004
Resolved 17 July 2004
Resolution: Repairs visually inspected and found satisfactory.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 July 2004 Resolved
Repair of replace raw water coolant suction line for diesel generator to the satisfaction of local PSCO by 17 July.
Condition: Improper/Lack of Maintenance
Due 17 July 2004
Resolved 17 July 2004
Resolution: Replacement line visually inspected and found satisfactory.
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 14 July 2004 Resolved
Install adequate amount of spanner wrenches in all fire hose stations by 17 July to the satisfaction of local PSCO.
Due 17 July 2004
Resolved 17 July 2004
Resolution: All stations found to have spanner wrenches.
Navigation › Collision/Grounding Avoidance › Radar
Issued 21 June 2004 Resolved
Second radar (3cm) was inoperable. Vessel requested Letter of Deviation to leave the port of Savannah.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 July 2004
Resolution: Second radar was checked by onscene marine inspector and was found operational.
Engineering
Issued 15 April 2004 Resolved
Remove excessive oil in bilge in aft engine room and forward starboard engine room area.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2004
Resolved 19 April 2004
Resolution: Excessive oil has been remobed.
Fire Fighting › Fire Pumps
Issued 13 November 2003 Resolved
Repair water leaks on both engineroom firepumps. Prior to departure from port and to the satisfaction of the attending classification society. LEGACY COMPONENT DESC: Pumpshaft
Action required: 705 - Other - as specified
Due 13 November 2003
Resolved 18 November 2003
Resolution: Repairs were made.
Fire Fighting › Emergency Fire Pumps
Issued 13 November 2003 Resolved
Repair fuel oil leaks on emergency firepump. Prior to departure from port and to the satisfaction of the attending classification society.
Action required: 705 - Other - as specified
Due 13 November 2003
Resolved 18 November 2003
Resolution: Repairs were made.
Engineering › Diesel Engine (propulsion-electric)
Issued 13 November 2003 Resolved
Repair fuel oil leaks coming from high pressure fuel pumps on stbd side generator. Prior to departure from port and to the satisfaction of the attending classification society. LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Action required: 705 - Other - as specified
Due 13 November 2003
Resolved 18 November 2003
Resolution: Repairs were made.
Pollution Prevention/Response › Prevention Equipment
Issued 13 November 2003 Resolved
Make permanent repairs to stbd bunkering station containment. Prior to using stbd side bunkering station in U.S. waters. LEGACY COMPONENT DESC: Fixed Containment
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Resolved 18 November 2003
Resolution: Repairs were made.
Pollution Prevention/Response › Prevention Equipment
Issued 25 April 2003 Resolved
The oily water separator's three way valve did not operate properly. Prove proper operation and proper arrangement of piping to the satisfaction of Class prior to arrival in the next U.S. port. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 April 2003
Resolved 27 June 2003
Resolution: RECIEVED REPORT FROM CLASS (RS) STATING THE REQUIRMENT FROM DEFICIENCY HAS BEEN FULLFILLED AND THE OIL FILTERING EQUIPMENT IS WITH IN MARPOL 73/78 REGULATIONS.
Electrical › Electrical Distribution System (service)
Issued 25 April 2003 Resolved
The vessel's 110v electrical distribution system is grounded. LEGACY COMPONENT DESC: Ground Detection
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 May 2003
Resolved 29 April 2003
Resolution: RECIEVED REPORT FROM CLASS (RS) STATING THAT THE 110V ELECTRICAL DISTRIBUTION SYSTEM IS GROUNDED. THE NAMED DEFICIENCY IS ELIMINATED.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 26 June 2002 Resolved
Main Engine auxiliary blower removed and sent ashore for repairs. Vessel must permanently repair and replace blower prior to departure. LEGACY COMPONENT DESC: Blower, Centrifugal
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 26 June 2002
Resolution: Received Technician report from [name withheld] attesting to the proper repair of the motor.
Engineering › Diesel Engine (auxiliary)
Issued 26 June 2002 Resolved
Auxiliary generator cooling water return line holed, patched and leaking between cooler and overboard valve. LEGACY COMPONENT DESC: Cooling Water
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 9 August 2002
Resolution: Inspected satisfactory.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 26 June 2002 Resolved
Main Engine auxiliary blower removed and sent ashore for repairs. Vessel must permanently repair and replace blower prior to departure. LEGACY COMPONENT DESC: Blower, Centrifugal
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 27 June 2002
Resolution: Received proper documentation, cleared deficiency.
Engineering › Diesel Engine (auxiliary)
Issued 26 June 2002 Resolved
No.2 Generator cooling water return line in way of cooler holed, patched and leaking. LEGACY COMPONENT DESC: Cooler
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 9 August 2002
Resolution: Inspected satisfactory.
Engineering › Freshwater System (jacketwater cooling)
Issued 26 June 2002 Resolved
Main Engine jacket water line located port side forward on control deck holed and patched. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 July 2002
Resolved 9 August 2002
Resolution: Inspected satisfactory.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 26 June 2002 Resolved
All shipboard toilets do not operate as designed. Repair toilets prior to next US port or provide statement that current arrangements are satisfactory. LEGACY COMPONENT DESC: Toilet
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 4 July 2002
Resolved 9 August 2002
Resolution: Inspected satisfactory
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 26 June 2002 Resolved
Two crew members currently living in hospital. Provide departure itinerary for both crewmembers prior to departure. LEGACY COMPONENT DESC: Berth
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Due 4 July 2002
Resolved 27 June 2002
Resolution: Recievied Itenery for crew members departing vessel and returning to Russia.
Accommodation/Occupational Safety › Medical/First Aid
Issued 26 June 2002 Resolved
Ships medicine chest is missing numerous items. Provide approved Medicine chest in accordance with flag rules. LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 4 July 2002
Resolved 9 August 2002
Resolution: Inspected satisfactory
Operations/Management › Vessel Safety Management
Issued 28 March 2002 Resolved
ISM Audit to be completed as per ISM code 5.4, 6.4 and 6.5. New personnel are not being trained properly, and master does not appear to be controlling drills in accordance with SOLAS regulations.
Action required: 705 - Other - as specified
Due 28 March 2002
Resolved 3 April 2002
Resolution: ISM Audit completed by Lloyd''s Register. Audit resulted in two non conformities and two observations being issued. The SMS did not always ensure compliance with mandatory rules, regulations, and effective response to emergency situations.
Operations/Management › Drills/Instruction
Issued 28 March 2002 Resolved
Crew is unable to perform satisfactory fire and abandon ship drills.
Action required: 705 - Other - as specified
Due 28 March 2002
Resolved 3 April 2002
Resolution: HELD SATISFACTORY FIRE AND ABANDON SHIP DRILLS.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 28 March 2002 Resolved
Fresh water line to toilets in deck storage room on third deck are holed and leaking.
Action required: 705 - Other - as specified
Due 28 March 2002
Resolved 3 April 2002
Resolution: FRESH WATER LINE TO TOILETS RENEWED.
Fire Fighting › Fire Main
Issued 28 March 2002 Resolved
Firemain has numerous leaks entire length of cargo deck starboard side and large leak at crossover BWO #2 hold forward amidship. Class to attest to integrity. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 3 April 2002
Resolution: VESSEL RENEWED PIPING ALONG FIREMAN.
Fire Fighting › Fire Hydrants
Issued 28 March 2002 Resolved
Firemain hydrant valve BWO #3 hold port side is inoperable and unable to be secured. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 3 April 2002
Resolution: FIREMANIN HYDRANT WAS REPLACED AND OPERATABLE.
Stability › Watertight Integrity
Issued 28 March 2002 Resolved
Gaskets to watertight door to crew passage way and windows to galley deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2002
Resolved 3 April 2002
Resolution: GASKETS HAVE BEEN RENEWED TO WATERIGHT DOORS AND WINDOWS.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 28 March 2002 Resolved
Sewage line leading to treatment tank in engine room holed and patched. LEGACY COMPONENT DESC: Toilet
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 30 April 2002
Resolved 9 August 2002
Resolution: Inspected satisfactory
Deck/Cargo › Cargo Stowage
Issued 28 March 2002 Resolved
Hydraulic ram seal BWO #4 hold starboard side is leaking excessively. LEGACY COMPONENT DESC: HYDRAULIC RAM SEAL
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 30 April 2002
Resolved 9 August 2002
Resolution: Inspected satisfactory.
Accommodation/Occupational Safety
Issued 4 September 2001 Resolved
All toilets throughout the vessel not working as designed. Crew is using buckets of water to flush toilets. Vessel is to make proper repairs to the satisfaction of the Coast Gaurd.
Condition: Unknown
Due 2 November 2001
Resolved 2 November 2001
Accommodation/Occupational Safety
Issued 4 September 2001 Resolved
Overflow cross connect pipe for both MSD tanks is completely holed in two places. Vessel is to make permanent repairs to the satisfaction of the Coast Gaurd.
Condition: Unknown
Due 2 November 2001
Resolved 2 November 2001
Navigation
Issued 4 September 2001 Resolved
Oily substance leaking through rudder shaft housing onto rudder. Vessel is to stop and repair leaks to the satisfaction of class prior to movement.
Condition: Unknown
Due 5 September 2001
Resolved 12 September 2001
Construction/Loadline
Issued 25 July 2001 Resolved
Vessel has 4 bolt flange for standard bilge discharge connection. (MARPOL 73/78 Annex I Reg 19)
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Engineering
Issued 25 July 2001 Resolved
Fuel oil vent screen covers are wasted and/or missing on main deck aft or no. 5 cargo hold. (SOLAS 74A Reg I/11)
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Accommodation/Occupational Safety
Issued 25 July 2001 Resolved
Piping to MSD is holed and leaking. No. 1 and 2 blowers are inoperable on the sewage treatment plant. (33CFR 159)
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Electrical
Issued 25 July 2001 Resolved
No.1 sea water service pump has temporary soft patch between sea chest valve and strainer. (SOLAS 74A I/11)
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Lifesaving
Issued 25 July 2001 Resolved
Lube oil and fuel oil on machinery and standing in containment areas. (SOLAS 74A I/11)
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Documentation
Issued 30 October 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 31 October 2000
Resolved 3 November 2000
Lifesaving
Issued 22 January 1999 Resolved
EXCESSIVE OIL IN MAIN & GENERATORS BILGES, PURIFIERS(L/O, H/O, D/O), STEERING GEAR, GENERATOR ENGINES, MDE, PUMP TRAYS, AND TANK DRAINS._x001C_ SOLAS 60 REG II/28._x001C_ CLEANUP ALL EXCESSIVE OIL PRIOR TO ENTRY NEXT US PORT.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Construction/Loadline
Issued 22 January 1999 Resolved
HOLE FROM LAUNDRY ROOM TO MAIN MACHINERY SPACE._x001C_ SOLAS 60 REG 1/II_x001C_ REPAIR PRIOR TO RETURN TO A US PORT.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Engineering
Issued 22 January 1999 Resolved
OIL LEAK ON THE DUPLEX L/O STRAINER FOT THE MDE._x001C_ SOLAS 60 REG II/28_x001C_ _x001C_ REPAIR PRIOR TO ENTRY NEXT US PORT
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Engineering
Issued 22 January 1999 Resolved
PERMANENT REPAIRS/OVERHAUL REQUIRED ON FUEL LINES AND PUMPS TO THE GENERATOR ENGINES TO ARREST LEAKS._x001C_ SOLAS 60 REG II/27_x001C_ MAKE REPAIRS PRIOR TO ENTRY NEXT US PORT.
Condition: Unknown
Due 29 March 1999
Resolved 29 March 1999
Fire Fighting
Issued 16 July 1998 Resolved
INTERNATIONAL SHORE CONNECTION MISSING.
Condition: Unknown
Due 16 July 1998
Resolved 20 July 1998
Lifesaving
Issued 16 July 1998 Resolved
BRIDGE WING LIFE RINGS WERE NOT PROPER WEIGHT.
Condition: Unknown
Due 31 July 1998
Resolved 23 July 1998
Fire Fighting
Issued 16 July 1998 Resolved
FIRE CONTROL PLAN MISSING.
Condition: Unknown
Due 31 July 1998
Resolved 23 July 1998
Lifesaving
Issued 16 July 1998 Resolved
LINE THROWING APPARATUS WAS OUTDATED.
Condition: Unknown
Due 16 July 1998
Resolved 20 July 1998
Lifesaving
Issued 8 April 1996 Resolved
STARBOARD LIFEBOAT ENGINE WILL NOT START. SOLAS 74 AMENDED III/18.3.
Condition: Unknown
Due 10 April 1996
Resolved 24 April 1996
Fire Fighting
Issued 18 October 1994 Resolved
The vessel's fire hose on the port side forward fire station was ruptured and needed replacing.
Condition: Unknown
Due 20 October 1994
Resolved 20 October 1994
Engineering
Issued 5 April 1993 Resolved
OILY WATER SEPARATOR ALARM NOT FUNCTIONING PROPERLY, REQUIRES CALABRATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 April 1993
Resolved 5 April 1993

Ownership record