← All vessels
TRIUMPH
Freight Ship · Bulk Carrier class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named TRIUMPH
TRIUMPH is a 1978 freight ship. The Coast Guard has recorded 75 inspections since 1985, most recently in January 2010, along with 48 deficiencies — 1 with no resolution recorded — and 14 operational controls.
Records from 1985 to 2010. Most recent: inspection, 8 January 2010.
- Built
- 1978
- Last inspected
- 8 January 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 48 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7622778 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7KW4
226006
Flag
MARSHALL ISLANDS
—
Maury page id
psix-226006
Inspections, by type
…with no type recorded52
Years with a record
26 calendar years (1985–2010)
The 75 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it8582 - Regulatory (Subpart C or D), Net Ton
8582 - Convention (Subpart B), Net Ton
27385 - Dead Weight, Ton
34897 - Displacement, Ton
17537 - Regulatory (Subpart C or D), Gross Ton
17537 - Convention (Subpart B), Gross Ton
8582 - Convention (Subpart B), Net Ton
27385 - Dead Weight, Ton
34897 - Displacement, Ton
17537 - Regulatory (Subpart C or D), Gross Ton
17537 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 75
8 January 2010
Ballast Water Examination · MARPOL Annex V Examination · ISPS III Exam · PII Safety Exam · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3660431
3 July 2009
ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3514815
11 September 2008
Deficiency Check · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3322443
11 September 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3322676
29 July 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3284107
28 July 2008
MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3278659
17 December 2007
PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3114906
15 December 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3116823
7 December 2007
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3111401
14 September 2007
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3065250
17 July 2007
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2998582
9 May 2007
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2922250
1 March 2007
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2879922
19 February 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2874167
4 February 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2866748
15 September 2006
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2779176
20 August 2006
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2753560
19 August 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2752817
9 March 2006
MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2599120
22 June 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2399134
6 May 2005
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2350705
7 March 2005
Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2304742
6 March 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2304411
30 November 2004
Random ISPS/MTSA/PSC · PII Safety Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2250328
25 August 2004
Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2175321
1 June 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2084881
18 March 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2026988
18 March 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2027507
12 January 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1985059
24 October 2003
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1930373
17 September 2003
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1907235
14 November 2002
Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1705638
6 November 2002
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1711063
29 October 2002
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1697580
28 May 2002
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1622660
6 January 2002
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1474440
16 March 2001
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 287968
26 July 2000
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 280302
10 December 1999
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 435847
29 March 1999
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 426942
13 October 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 421311
13 July 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 405385
1 January 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 133831
2 December 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 397985
7 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 392053
2 January 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 648122
19 December 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 386283
16 November 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 454700
13 October 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 383641
10 April 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 377089
27 June 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 368051
30 April 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 366424
2 December 1993
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 362814
26 October 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 361595
10 September 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 687351
9 September 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 497379
12 August 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 99961
16 April 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 357572
13 December 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 512371
16 June 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 646947
24 April 1992
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 350560
27 March 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 351454
29 August 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 646946
23 July 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 495816
22 January 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 341481
17 September 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 339328
6 November 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 333513
13 August 1988
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 325064
23 May 1988
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 540845
21 August 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 317997
27 April 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 315725
25 September 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 529779
1 March 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 307222
25 November 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 508271
21 February 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 300488
Deficiency record · 48
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 8 January 2010
Resolved
Vessel failed to maintain engine room alarm logs as required by SMS. PSCO's recommended an external audit be conducted to determine company and ship adherence to SMS and ISM code.
Construction/Loadline › Structures › Door
Issued 8 January 2010
Resolved
The fire doors located on the port and starboard side of the galley are not self-closing because the device to close the doors has been removed as evident by holes drilled in doors. PSCO's are unable to determine the class boundary because the fire control plan does not illustrate the class boundary.
Construction/Loadline › Structures › Door
Issued 8 January 2010
Resolved
Mooring winch door in the steering room is missing closing device and structural integrity deminished by a hole punctured in it. Unsure of door's class boundary, does not show up on fire control plan.
Fire Fighting › Fire Hydrants › Material
Issued 8 January 2010
Resolved
The fire plug located aft of bridge midship is cracked andwasted resulting in large amounts of water leaking when fire main is charged because the fire plug does not maintain adequate pressure this poses a fire hazard.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 January 2010
Resolved
Fire control plans do not match and are not up to date. Fire control plans should be kept up to date and alterations recorded as soon as practicable.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 3 July 2009
Resolved
Vessel has only one functioning Breathing Apparatus and does not meet requirement for two fully functional fire suits. Written to satisfaction of Coast Guard Prior to Departure.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 25 July 2008
Resolved
The emergency fire pumps fuel tank does not have the capability of being closed from outside the space. Solas 60 chII reg69(c)
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 25 July 2008
Resolved
The flash hoods on both fire outfits are damaged/worn, in addition the boots on one outfit do not fit the firefighter leaving one of the firefighters unable to fight a fire. SOLAS 60 ChII Reg 63
Lifesaving › Lifeboat Equipment › Food Ration
Issued 25 July 2008
Resolved
The rations in the lifeboats have lost its seal allowing moisture in compromising the contents. Solas 60 ChII reg11 (a) (xii)
Lifesaving › Launching Appliances › Davit
Issued 25 July 2008
Resolved
The limit switch on the port lifeboat davit switch is inoperable. Solas 60 ChIII reg29
Navigation › Collision/Grounding Avoidance › Radar
Issued 17 December 2007
Resolved
The vessels Primary Radar system is inoperable.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 December 2007
Resolved
15 PPM Alarm fitted with electrical switch to deactivate alarm, allowing OWS to operate without auto stopping device. Team Conducted expanded exam of OWS, Including removal of discharge piping and review of Oil recorded with conclusion vessel is not suspected of unauthorized discharge.15 PPM arrangement is to be modified to prevent activity of operating OWS without engaging auto stopping device.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 17 December 2007
Resolved
Hydraulic Line forward of Hydraulic line/control manifold on #2 cargo hatch STBD side has soft patch. To be corrected to the satisfactory of Classification society.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 14 September 2007
Resolved
14Sep07 The vessel was granted a Letter of Deviation to enter the Port of Corpus Christi with an inoperable ARPA. The following restrictions are required: daylight transit only.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 17 July 2007
Resolved
17JUL07 The vessel is granted a Letter of Deviation to enter the port of Corpus Christi with an inoperable ARPA. The following restrictions are: Transit is limited to daylight transit only.
Navigation › Collision/Grounding Avoidance › Radar
Issued 19 February 2007
Resolved
Vessel's secondary marine radar system is inoperative.
Navigation › Collision/Grounding Avoidance › Radar
Issued 4 February 2007
No resolution recorded
Vessels secondary radar is inoperable. Vessel granted an inbound and outbound deviation. Refer to activity number 2866748 for details on radar.
Navigation › Collision/Grounding Avoidance › Radar
Issued 20 August 2006
Resolved
The vessel was granted a DTD for an inoperable marine radar. Repair or replace prior to next U.S. port.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 30 November 2004
Resolved
Plugs for closing drains missing from all containment areas.
Fire Fighting › Nozzles › Type
Issued 30 November 2004
Resolved
Nozzles not of the approved type found in the engine room. Suicide nozzles to be replaced with variable spray type.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 November 2004
Resolved
No machinary guard in place around emergency fire pump chain and belt drive.
Fire Fighting › Firemans Outfit
Issued 17 September 2003
Resolved
The reflective material on Both fireman outfits are worn out. LEGACY COMPONENT DESC: Protective Clothing
Documentation › Certificates/Documents
Issued 17 September 2003
Resolved
Document expired in MISLE. LEGACY COMPONENT DESC: Classification Document
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 17 September 2003
Resolved
Document expired in MISLE
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 17 September 2003
Resolved
Document expired in MISLE
Documentation › Certificates/Documents
Issued 17 September 2003
Resolved
document expired in MISLE LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Documentation › Certificates/Documents › IOPP Certificate
Issued 17 September 2003
Resolved
document expired in MISLE
Documentation › Certificates/Documents › International Load Line Certificate
Issued 17 September 2003
Resolved
document expired in MISLE
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 17 September 2003
Resolved
document expired due to name change
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 17 September 2003
Resolved
document expired in MISLE
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 17 September 2003
Resolved
document invalid due to name change
Documentation › Certificates/Documents
Issued 17 September 2003
Resolved
invalid due to name change LEGACY COMPONENT DESC: Certificate of Registry
Navigation › Collision/Grounding Avoidance
Issued 6 November 2002
Resolved
Vessel issued LOD to enter the Port of Corpus Christi without a properly operating primary radar with the understanding that the equipment must be operational prior to departure. LEGACY COMPONENT DESC: Radar
Navigation › Collision/Grounding Avoidance
Issued 29 October 2002
Resolved
ARPA inoperable. Issued Letter of Deviation allowing vessel to depart the port of Savannah. Arrangements have been made by vessel owner to have repairs effected at next port Corpus Christi, TX. LEGACY COMPONENT DESC: Automatic Radar Plotting Aid (ARPA)
Navigation
Issued 26 July 2000
Resolved
VESSEL REQUESTED TO ENTER PORT OF CHARLESTON WITH INOPERATIVE SECONDARY RADAR. _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 2 December 1996
Resolved
Make repairs to discharge pipe on #2 ballast/fire pump. (has holes)
Engineering
Issued 2 December 1996
Resolved
Make repairs to main engine air cooler water discharge pipe. (has holes)
Lifesaving
Issued 7 June 1996
Resolved
PROVIDE FOUR ADDITIONAL SELF-IGNITING LIGHTS FOR LIFE BUOYS. CORRECT PRIORTO DEPARTURE FORM THE PORT ON NEW ORLEANS. SOLAS60 CH3 REG21
Navigation
Issued 7 June 1996
Resolved
REPAIR #1 RADAR WHICH INCLUDES ARPA. CORRECT PRIOR TO DEPARTURE FROM THE PORT OF NEW ORLEANS. 33CFR164-11.
Navigation
Issued 19 December 1995
Resolved
Vessel entered into the navigatiable waters of the US with a faulity Gyro compass with notifying the Captain of the Port as required by 33 C.F.R.164.53
Navigation
Issued 26 October 1993
Resolved
CHART 12326 MISSING NTM CORRECTIONS 9/93, 33/93, 39/93; CHART 12327 MISSINGNTM CORRECTIONS 34/93, 36/93, 39/93; AND CHART 12334 MISSING NTM CORRECTIONS 3/92, 24/92, 26/92, 50/92, 21/93, 39/93.
Documentation
Issued 27 March 1992
Resolved
THE VESSEL DID NOT RECORD THE RESULTS OF THE BUNKER LINE PRESSURE TEST REQUIRED BY 33 CFR 156.170(f)(2).
Navigation
Issued 27 March 1992
Resolved
THE VESSEL DID NOT HAVE U.S. CHARTS 12311 AND 12313 CORRECTED TO THE LATESTNOTICE TO MARINERS.
Navigation
Issued 6 November 1989
Resolved
VESSEL HAD A 1988 EDITION OF THE US COAST PILOT ON BOARD NOT CORRECTED UP TO DATE THROUGH THE LATEST NOTICE TO MARINERS.
Navigation
Issued 6 November 1989
Resolved
VESSEL HAD A 1989 EDITION OF THE U.S. LIGHT LIST ON BOARD, NOT CORRECTED UP TO DATE THROUGH THE THE LATEST NOTICE TO MARINERS.
Navigation
Issued 6 November 1989
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WHITHOUT AN OPERATIONAL SECOND RADAR.
Navigation
Issued 6 November 1989
Resolved
VESSEL DID NOT HAVE AN INLAD NAVIGATIONAL RULES ON BOARD.
Navigation
Issued 6 November 1989
Resolved
CHARTS, 12326, 12327, AND 12334 NOT CORRECTED UP TO DATE THROUGH THE LATEST NOTICE TO MARINERS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.