Records from 1984 to 1990. Most recent: inspection, 23 April 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
23 April 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 474713
23 October 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 333286
29 July 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 436983
26 April 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 329991
1 April 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 536016
16 September 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 325624
8 July 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 324372
28 March 1988
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 322322
23 March 1988
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 526203
24 September 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 318630
26 August 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 310978
9 August 1984
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 297372
Navigation
Issued 23 October 1989
Resolved
VESSEL FAILED TO ADEQUATELY VISUALLY INSPECT STEERING GEAR AND CONNECTING LINKAGE. SPECIFICALLY, THE NUT ON ONE OF THE FOUR BOLTS SECURING THE CONNECTING LINKAGE WAS NOT SECURED WITH A LOCKING WASHER OR COTTER PIN. THEBOLT HAD A SMOOTH WASHER ON IT, AND WAS LOOSE IN THE CONNECTING LINKAGE.
Condition: Unknown
Due 23 October 1989
Resolved 23 October 1989
Navigation
Issued 23 October 1989
Resolved
US CHART 18645, 20TH ED, 21FEB87, NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINER CORRECTIONS AS FOLLOWS:1987-19,29,34,36,41. 1988-2,18,24,28,32, 34,42.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 23 October 1989
Resolved
EQUIPMENT TEST REQUIRED BY 33CFR164.25 WAS NOT RECORDED IN VESSEL'S LOG.
Condition: Unknown
Due 23 October 1989
Resolved 23 October 1989
Engineering
Issued 23 October 1989
Resolved
VESSEL ABLE TO BYPASS 15PPM OIL WATER SEPERATOR ALARM BEFORE DISCHARGING BILGE WASTE DIRECTLY OVERBOARD.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 23 October 1989
Resolved
VESSEL DID NOT HAVE A REMOTE STEERING SYSTEM POWER FAILURE ALARM.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 23 October 1989
Resolved
VESSEL DID NOT HAVE FIXED CONTAINER OR ENCLOSED DECK AREA UNDER OR AROUND FUEL OIL TANK VENTS. VESSEL WAS CONSTRUCTED IN 1978 AND IS 18,570 GROSS TONS.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 8 July 1988
Resolved
33CFR156.120 NO MECHANICAL MEANS OF CLOSURE ON DISCHARGE CONTAINMENT DRAIN. AUTHORITY CITE: 33USC1321(J)(1)(C) PENALTY CITE: 33USC1321(J)(2)
Condition: Unknown
Due 8 July 1988
Resolved 8 July 1988
Fire Fighting
Issued 24 September 1987
Resolved
FIRE STATION HOSE LOCATED STBD SIDE MAIN DECK AFT NOT KEPT IN GOOD ORDER ASREQUIRED BY 1974 SOLAS CONVENTION CHAPTER II-2, PART A, REGULATION 15.
Condition: Unknown
Due 16 September 1988
Resolved 24 September 1987
Deck/Cargo
Issued 24 September 1987
Resolved
CONTAINMENT FOR BUNKERING STATIONS HAS NO MEANS FOR MECHANICAL CLOSURE AS EQUIRED BY 33CFR155.310(A)(3).
Condition: Unknown
Due 24 September 1987
Resolved 24 September 1987
Lifesaving
Issued 24 September 1987
Resolved
LIFE BOUY SELF IGNITING LIGHT LOCATED STBD MAIN DECK AFT NOT OPERATIONAL ASREQUIRED BY 1974 SOLAS CONVENTION, CHAPTER III, PART A, REGULATION 21(F).
Condition: Unknown
Due 24 September 1987
Resolved 24 September 1987
Engineering
Issued 24 September 1987
Resolved
OIL AND OILY WASTE DRAINED INTO BILGE IN DIRECT VIOLATION OF 33CFR155.770
Condition: Unknown
Due 16 September 1988
Resolved 24 September 1987