Records from 1984 to 2006. Most recent: inspection, 25 February 2006.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
25 February 2006
Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2591752
28 February 2002
Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1490184
25 May 2001
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 290340
21 July 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 280042
18 January 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 273350
17 January 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 177489
27 January 1999
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 424735
8 February 1998
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 412114
5 May 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 403286
5 June 1996
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 391884
26 May 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 378901
14 November 1994
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 372282
28 August 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 369751
19 July 1993
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 359641
11 September 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 502331
22 February 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 348843
2 May 1991
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 343246
12 January 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 482713
12 March 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 335796
10 January 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 327796
24 March 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 322000
7 April 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 485138
22 October 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 311928
5 March 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 485855
17 July 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 303126
28 February 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 438906
26 July 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 296995
Lifesaving
Issued 25 May 2001
Resolved
Worn or Missing support brackets on handhold rails on underside of port lifeboat.
Condition: Unknown
Due 15 June 2001
Resolved 28 February 2002
Resolution: HANDRAILS WELDED TO LIFEBOAT
Electrical
Issued 25 May 2001
Resolved
Emergency light, outdoor fixture, port side of vessel near embarkation station broken. Missing metal protective ring on fixture also mizzing.
Condition: Unknown
Due 25 May 2001
Resolved 29 May 2001
Accommodation/Occupational Safety
Issued 18 January 2000
Resolved
Port gangway was damaged by mobile gantry at offloading port - ALCOA Terminal, Point Comfort, TX.
Condition: Unknown
Due 21 July 2000
Resolved 21 July 2000
Construction/Loadline
Issued 18 January 2000
Resolved
Alarm for 15 ppm OWS was not functioning at the time of inspection.
Condition: Unknown
Due 19 January 2000
Resolved 19 January 2000
Navigation
Issued 18 January 2000
Resolved
Bridge rudder angle indicators (centerline and bridge wing repeaters) did not reflect the actual position of the ship's rudder (4 to 5.5 degree difference).
Condition: Unknown
Due 18 January 2000
Resolved 19 January 2000
Construction/Loadline
Issued 5 May 1997
Resolved
Provide class survey report attesting to the proper operation of the oily water seperator 15ppm alarm, 33CFR155.370(a)(2).
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998
Documentation
Issued 5 June 1996
Resolved
ILO-147 In that the vessel did not have copies of medical examinations forall members of the crew.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Engineering
Issued 5 June 1996
Resolved
Flame screens on diesel and bunker tank vents worn and rusted, allowing holes to form in the mesh.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Engineering
Issued 5 June 1996
Resolved
33 C.F.R. 156.170(f)(2) The vessel's fuel oil piping had not been static liquid pressure tested, as required by 33 C.F.R. 156.170(c)(4), within the last year.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Accommodation/Occupational Safety
Issued 5 June 1996
Resolved
ILO-147 The vessel's hospital spaces did not have as equipment a body bag or a pair of crutches.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996