MAURY USCG vessel records Sign in
← All vessels

KESTREL

KESTREL is a industrial vessel. The Coast Guard has recorded 16 inspections since 2003, most recently in December 2011, along with 9 deficiencies and 3 operational controls.

Records from 2003 to 2011. Most recent: inspection, 13 December 2011.

Built
Not recorded
Last inspected
13 December 2011
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7628758 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226074
Flag
VANUATU
—
Maury page id
psix-226074

Inspections, by type

…with no type recorded4
Years with a record 7 calendar years (2003–2011)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)306.3 ft × 82.0 ft × 22.0 ft
Registered tonnagegross 4,604 / net 1,381
ITC dimensions (L × B × D)306.3 ft × 82.0 ft × 22.0 ft
ITC tonnagegross 4,604 / net 1,381
BuilderFAR EAST LIVINGSTON SHIPBUILDING COMPANY · SINGAPORE
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUMA, LA
Trade endorsementsRegistry
DocumentationNo Operation - PM · issued 22 September 2015
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1381 - Convention (Subpart B), Net Ton
5153 - Dead Weight, Ton
10112 - Displacement, Ton
4604 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 16

13 December 2011 Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4204932
28 January 2010 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3671373
29 July 2009 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3549631
30 April 2009 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3466900
16 April 2009 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3453665
19 February 2009 Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3420312
2 September 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3312091
15 June 2007 Ballast Water Examination · ISPS III Exam · PI Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2962403
29 September 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2797677
11 September 2006 Ballast Water Examination · STCW 95 Exam · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2610480
17 December 2003 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1965852
8 September 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1899706
26 August 2003 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1887889
26 June 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1827765
24 June 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1825769
24 June 2003 Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1825948

Deficiency record · 9

Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 13 December 2011 Resolved
Thermal insulation of boundaries shall have due regard to the fire risk of the space and adjacent spaces. Portside steering gear room has half of the fire protection insulation missing torn and wasted.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 9 January 2012
Resolution: Vessel provided evidence of proper fire instulation.
Operations/Management › Pollution › Arrival Reporting, Garbage
Issued 13 December 2011 Resolved
Each discharge operation or incineration shall be recorded in the garbage record book. The vessels record book has several missing and incorrect entries in the record book.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 9 January 2012
Resolution: Vessel provided evidence of procedures that are in place to ensure proper garbage record book entries.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 13 December 2011 Resolved
Each operation of the OWS shall be fully recorded without delay in the oil record book part I, so that all entries in the boo appropriate to that operation are completed. The vessels ORB has several incorrect entries on November 26th, 18th, October 28th, 1st and September 2nd, along with oil being transferred to a reception vessel not being recorded.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 9 January 2012
Resolution: Vessel provided evidence of procedures to ensure proper entries are being made to the ORB accounting for their oil on board their vessel.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 December 2011 Resolved
Effective guardrails or bulwarks shall be fitted to all exposed parts of the freeboard and superstructure decks. Starboard side handrail near lifeboat davit does not meet guardrail height requirements of 1 meter and poses a hazardous environment to vessel crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 9 January 2012
Resolution: Vessel provided evidence of repairs made to the hand rail on the starboard side handrail.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 2 September 2008 Resolved
Owner/operator has not rcvd required authorization to operate on the navigable waters of the U.S. Nontank VRP must meet the required elements IAW 33 USC 1321(j)(5)(D) for each geographic specific area in which it operates. Vessel only has submittion letter and plan.
Action required: 15 - Rectify deficiencies by next port
Resolved 19 February 2009
Resolution: Reviewed vessels status on www.e-vrp.com. The vessels plan is approved for interim ops and has approval for every COTP.
Construction/Loadline › Markings
Issued 24 June 2003 Resolved
Repaint loadline markings in contrasting color. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Due 22 July 2003
Resolved 17 December 2003
Resolution: Loadlines were painted with white paint.
Documentation › Manuals/Policy Documentation
Issued 24 June 2003 Resolved
The maneuvering facts sheet did not have the warning statement listed. 33CFR 164.35 LEGACY COMPONENT DESC: Maneuvering Information
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 26 June 2003
Resolution: Warning statement placed on manuervering fact sheet
Documentation › Logs/Records
Issued 24 June 2003 Resolved
Vessel did not conduct or place the entry of the pre arrival tests into the bridge log book. Vessel shall conduct and log the pre arrival tests into the bridge logbook prior to the next us port. LEGACY COMPONENT DESC: Maneuvering Performance Test Results
Condition: Design Flaw
Action required: 15 - Rectify deficiencies by next port
Resolved 26 June 2003
Resolution: Vessel conducted pre arrival tests in the bridge log book after conducting sea trials off the coast of Galveston, TX.
Documentation › Manuals/Policy Documentation
Issued 24 June 2003 Resolved
Vessel did not have onboard any copies of 33CFR. Vessel shall have copies onboard prior to departure from port. LEGACY COMPONENT DESC: Maneuvering Information
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2003
Resolution: All 33CFR''s are onboard vessel.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.