MAURY USCG vessel records Sign in
← All vessels

FINNSNES

FINNSNES is a 1978 freight ship. The Coast Guard has recorded 32 inspections since 1984, most recently in July 2002, along with 22 deficiencies and 3 operational controls.

Records from 1984 to 2002. Most recent: operational control imposed, 30 July 2002.

Built
1978
Last inspected
30 July 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7632888 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226121
Flag
CYPRUS
—
Maury page id
psix-226121

Inspections, by type

…with no type recorded29
Years with a record 17 calendar years (1984–2002)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it12394 - Dead Weight, Metric Ton
16941 - Displacement, Metric Ton
4542 - Convention (Subpart B), Net Ton
4542 - Regulatory (Subpart C or D), Net Ton
8967 - Convention (Subpart B), Gross Ton
8967 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

30 July 2002 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1654253
28 July 2002 Deficiency Check · Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1653471
12 July 2002 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1643863
18 April 2002 Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1606363
23 April 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 289457
26 September 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 72327
27 August 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 176110
24 August 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 281534
31 July 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 280531
8 July 1999 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 430469
19 February 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 425587
3 April 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 414827
12 July 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 405582
10 June 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 404612
18 November 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 397609
24 May 1996 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 391521
20 May 1996 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 391339
11 March 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 388265
13 October 1995 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 383679
6 September 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 360510
1 February 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 537028
7 November 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 354275
8 August 1991 Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 345244
7 January 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 341174
22 November 1989 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 333825
15 May 1989 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 497433
7 September 1988 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 325491
5 August 1987 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 317648
26 August 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 310954
24 February 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 460687
26 September 1985 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 304347
5 September 1984 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 297768

Deficiency record · 22

Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 28 July 2002 Resolved
During engine casualty eng department expened CO2 system, LEGACY COMPONENT DESC: Quantity of CO2
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 July 2002
Resolved 29 July 2002
Resolution: recieved class report
Engineering › Diesel Engine (propulsion-direct drive)
Issued 28 July 2002 Resolved
Piston froze in cylinder cause unknown at this time, Class to attest to the repairs LEGACY COMPONENT DESC: Piston
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 July 2002
Resolved 29 July 2002
Resolution: Recieved Class report
Engineering › Diesel Engine (propulsion-direct drive)
Issued 28 July 2002 Resolved
# 12 clylinder head leakage water from around upper o-ring seals, Class to attest to repair LEGACY COMPONENT DESC: Cylinder Head
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2002
Resolved 29 July 2002
Resolution: Recieved Class report
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 28 July 2002 Resolved
Control room A/C unit backing up causing water to stand under and around the electrical swicthboard, Class to attest to repair
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 July 2002
Resolved 29 July 2002
Resolution: Recieved Class report
Documentation › Certificates/Documents
Issued 10 July 2002 Resolved
Provide an original or certified copy of the Document of Compliance from class. LEGACY COMPONENT DESC: Document of Compliance (ISM)
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 28 July 2002
Resolution: Cleared item
Pollution Prevention/Response › Prevention Equipment
Issued 10 July 2002 Resolved
Provide mechanical plugs for bunkering station and fuel oil overfill vents. LEGACY COMPONENT DESC: Overfill Devices
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 28 July 2002
Resolution: Cleared Item
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 10 July 2002 Resolved
Provide certification that fixed CO2 system is operating satisfactory.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 28 July 2002
Resolution: Cleared item
Documentation › Logs/Records
Issued 10 July 2002 Resolved
Ensure that the pre-arrival test, steering test, and emergency steering drills are logged in the bridge. LEGACY COMPONENT DESC: Logbook (official)
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 28 July 2002
Resolution: Cleared Item
Lifesaving › Lifeboat
Issued 10 July 2002 Resolved
Repair rubber bumpers to protect hull of the starboard lifeboat. LEGACY COMPONENT DESC: Fender
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 28 July 2002
Resolution: Cleared Item
Navigation
Issued 23 April 2001 Resolved
PROVIDE ECHO DEPTH SOUNDER WITH PAPER.
Condition: Unknown
Due 23 April 2001
Resolved 24 April 2001
Deck/Cargo
Issued 31 July 2000 Resolved
REPAIR SUPPORT FOR THE MOVING RAIL OF THE #1 CARGO HATCH PRIOR TO NEXT US PORT.
Condition: Unknown
Due 25 August 2000
Resolved 25 August 2000
Engineering
Issued 31 July 2000 Resolved
DEMONSTRATE PROPER OPERATION OF OILY WATER SEPARATOR AND ALARM AT NEXT US PORT.
Condition: Unknown
Due 25 August 2000
Resolved 25 August 2000
Lifesaving
Issued 31 July 2000 Resolved
CONDUCT ABANDON SHIP DRILL AT NEXT US PORT (COULD NOT CONDUCT DRILL DUE TO CARGO AND BUNKERING OPERATIONS).
Condition: Unknown
Due 25 August 2000
Resolved 25 August 2000
Fire Fighting
Issued 31 July 2000 Resolved
CONDUCT FIRE DRILL AT NEXT US PORT (COULD NOT CONDUCT DRILL DUE TO CARGO AND BUNKERING OPERATIONS).
Condition: Unknown
Due 25 August 2000
Resolved 25 August 2000
Fire Fighting
Issued 31 July 2000 Resolved
DEMONSTRATE PROPER OPERATION OF EMERGENCY FIRE PUMP PRIOR TO DEPARTURE.
Condition: Unknown
Due 31 July 2000
Resolved 1 August 2000
Engineering
Issued 19 February 1999 Resolved
ESTABLISH THAT THE OILY WATER SEPARATOR IS IN WORKING ORDER TO THE SATISFACTION OF CLASS SOCIETY PRIOR TO VESSEL DEPARTURE.
Condition: Unknown
Due 19 February 1999
Resolved 4 March 1999
Documentation
Issued 19 February 1999 Resolved
CLASS SOCIETY TO PROVIDE STATEMENT ATTESTING THAT ITEMS SJ01 AND SJ02 ISSUED UNDER THIS CASE ON 19FEB99 HAVE BEEN CORRECTED PRIOR TO VESSEL DEPARTURE.
Condition: Unknown
Due 19 February 1999
Resolved 4 March 1999
Fire Fighting
Issued 19 February 1999 Resolved
REPAIR THE FIXED EMERGENCY FIRE PUMP TO THE SATISFACTION OF CLASS SOCIETY _x001C_PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 February 1999
Resolved 4 March 1999
Documentation
Issued 10 June 1997 Resolved
EXPIRED SAFETY CONSTRUCTION CERTIFICATE. (SOLAS 74(AMD), CH. I, REG. 12,14)
Condition: Unknown
Due 10 June 1997
Resolved 19 June 1997
Documentation
Issued 10 June 1997 Resolved
PORT AND STARBOARD LOADLINE MARKINGS NOT PAINTED IN CONTRASTING COLORS._x001C_ (ILLC 66, ANNEX I/8)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 July 1997
Resolved 12 July 1997
Navigation
Issued 7 January 1991 Resolved
A VIO OF 33 CFR 164.33 IN THAT THE MOST RECENT ED. OF U.S. TIDE TABLES, OR IT'S EQUIVALENT, AS REQUIRED BY 33 CFR 164.33 (a)(3)(i) WERE NOT O/B. THE VSL HAD O/B TIDAL TABLES DTD 1990. THE MOST CURRENT ED. OF U.S. TIDAL TABLES IS DTD 1991.
Condition: Unknown
Due 7 January 1991
Resolved 7 January 1991
Navigation
Issued 7 January 1991 Resolved
A VIO OF 33 CFR 164.33 IN THAT THE MOST RECENT ED.OF U.S. TIDAL CURRENT TABLES, OR IT'S FOREIGN EQUIVALENT, AS REQUIRED BY 33 CFR 164.33 (a)(3)(ii)WERE NOT O/B. THE VSL HAD O/B TIDAL CURRENT TABLES DTD 1990. THE MOST RECENT ED. OF U.S. TIDAL CURRENT TABLES IS DTD 1991.
Condition: Unknown
Due 7 January 1991
Resolved 7 January 1991

Ownership record