Records from 1985 to 1999. Most recent: inspection, 16 August 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
16 August 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 431938
2 August 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 110618
16 January 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 424396
14 September 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 450315
3 November 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 409511
6 March 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 388549
9 January 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 373850
18 November 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 372305
21 September 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 370726
21 September 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1181545
8 May 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 366689
24 November 1993
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 362543
21 April 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 350211
5 June 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 539031
6 December 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 340718
4 June 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 330751
15 May 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 323143
11 May 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 315946
20 January 1987
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 438977
10 September 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 467680
25 February 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 300135
Navigation
Issued 16 January 1999
Resolved
INLAND NAVIGATION RULES ON VESSEL OUTDATED. CURRENT EDITION MUST BE ONBOARD PRIOR TO MOVEMENT UPRIVER.
Condition: Unknown
Due 17 January 1999
Resolved 17 January 1999
Electrical
Issued 6 March 1996
Resolved
A VIO OF SOLAS 60 IN THAT THE WATER SUPPLY TO GENERATOR NEEDS PERMENANT REPAIRS._x001C_ _x001C_ REPAIR TO SATISFACTION OF BV SURVEYOR.
Condition: Unknown
Due 13 March 1996
Resolved 12 March 1996
Documentation
Issued 6 March 1996
Resolved
A VIO OF 33 CFR 155.820(b) IN THAT THE BUNKERLINE PRESSURE TESTS WERE NOT DOCUMENTED._x001C_ _x001C_ CORRECT PRIOR TO BUNKERING IN U.S._x001C_
Condition: Unknown
Due 20 March 1996
Resolved 12 March 1996
Electrical
Issued 6 March 1996
Resolved
A VIO OF SOLAS 60 IN THAT THE LIGHT FIXTURE ABOVE THE E-FIRE PUMP IS BROKEN._x001C_ _x001C_ REPAIR TO SATISFACTION OF BV SURVEYOR._x001C_
Condition: Unknown
Due 13 March 1996
Resolved 12 March 1996
Engineering
Issued 6 March 1996
Resolved
A VIO OF SOLAS 60 IN THAT THE HOT WATER SUPPLY TANK NEEDS PERMENANT REPAIRS._x001C_ _x001C_ REPAIR TO SATISFACTION OF BV SURVEYOR._x001C_
Condition: Unknown
Due 13 March 1996
Resolved 12 March 1996
Fire Fighting
Issued 6 March 1996
Resolved
A VIO OF SOLAS 60 IN THAT THE MAIN FIRE PUMP DISCHARGE GAUGE NEEDS PERMENANT REPAIRS._x001C_ _x001C_ REPAIR TO SATISFACTION OF BV SURVEYOR._x001C_
Condition: Unknown
Due 13 March 1996
Resolved 12 March 1996
Fire Fighting
Issued 21 September 1994
Resolved
Vessel had three wasted sections on fire main stbd side.
Condition: Unknown
Due 6 December 1994
Resolved 6 December 1994
Documentation
Issued 25 February 1985
Resolved
THE ENTRIES IN THE OIL RECORD BOOK REQ BY 33 CFR 151.25 WERE NOT PROPERLY RECORDED.
Condition: Unknown
Due 25 February 1985
Resolved 25 February 1985
Documentation
Issued 25 February 1985
Resolved
THE OTP REQ BY 33 CFR 155.720 DID NOT MEET THE REQ OF 33 CFR 155.750 IN THAT THEY DID NOT CONTAIN: A LIST OF PRODUCTS TRANSFERRED, NUMBER OF PERSONS REQ TO BE ON DUTY DURING TRANSFER, DUTIES BY TITLE, PROCEDURES FOR CLOSING VALVES, PROCEDURES FOR EMPTYING CONTAINMENT.
Condition: Unknown
Due 25 February 1985
Resolved 25 February 1985