MAURY USCG vessel records Sign in
← All vessels

AKADAN BULK

AKADAN BULK is a 1995 freight ship. The Coast Guard has recorded 17 inspections since 1984, most recently in December 1995, along with 94 deficiencies and 1 operational control.

Records from 1984 to 1995. Most recent: inspection, 8 December 1995.

Built
1995
Last inspected
8 December 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7634018 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226137
Flag
SPAIN
—
Maury page id
psix-226137

Inspections, by type

…with no type recorded16
Years with a record 9 calendar years (1984–1995)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10232 - Regulatory (Subpart C or D), Net Ton
26973 - Dead Weight, Ton
33376 - Displacement, Ton
15581 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

8 December 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 752597
7 December 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 203935
7 December 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 385596
18 January 1995 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 440766
16 September 1994 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 703056
12 September 1994 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 370260
7 September 1994 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 370184
4 February 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401813
1 April 1993 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 357227
28 October 1991 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 506012
2 April 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 342807
26 January 1990 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 334994
3 January 1989 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 328047
30 November 1987 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 319934
10 December 1986 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 448267
10 March 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 307313
10 August 1984 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 297702

Deficiency record · 94

Engineering
Issued 7 December 1995 Resolved
Make permanent repairs to the leaking manhole cover from the purifier tank to the E/R double bottom cofferdam. Clean and gas gree the cofferdam._x001C_ _x001C_ MARPOL 73/78 I/9.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
Hole in bottom of engineroom double bottom cofferdam was temporarily repaired with a doubler plate. Final repairs to be made prior to return toa U. S. port._x001C_ ICLL 66 I/1
Condition: Unknown
Due 15 January 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 7 December 1995 Resolved
Proper prearrival tests were not conducted._x001C_ _x001C_ _x001C_ 33 CFR 164.25(a)
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Lifesaving
Issued 7 December 1995 Resolved
Make permanent repairs to the broken equipment box handles on the port lifeboat._x001C_ _x001C_ SOLAS 60 III/11.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Lifesaving
Issued 7 December 1995 Resolved
Provide 3 GMDSS VHF radio's on vessel._x001C_ _x001C_ _x001C_ SOLAS 74 III/6.2.1.1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Identify the wasted section of piping in #5, port, upper wing ballast tank.Perform extended survey and repairs as required; provide class report._x001C_ _x001C_ ICLL 66 II/22.5
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
Permanently repair the patched cooling line to the center generator engine.(Engine is currently down to replace coupling and align generator.)_x001C_ _x001C_ SOLAS 60 II/26
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
Make permanent repairs to the stbd generator engine. There is a severe exhaust leak from the crank case vent / relief valve. The engine is unusuable until repairs made._x001C_ SOLAS 60 II/26
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Fire Fighting
Issued 7 December 1995 Resolved
The emergency fire pump is not operational. It may require a complete rebuilt as it was recently underwater. Make necessary repairs and prove proper operation._x001C_ SOLAS 60 II/65.b.ii
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
Determine the cause of the massive flooding of the emergency fire pump space. Water appeared to be up to 4-5 feet above the deck plates recently.Make repairs / corrections as necessary._x001C_ ICLL 66 I/1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
Repair the patched overhead (port, aft, btwn frames) into the Chain Locker space (?). This many have been the source of flooding into the emergency fire pump space. _x001C_ ICLL 66 I/1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
Remove all water from the bilges of the emergency fire pump space and rinseall silt from the deck plates._x001C_ _x001C_ SOLAS 60 II/12.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
Provide a class report on the damaged (inset) port, aft bulkhead & side shell of the emergency fire pump space. Side shell is inset 6-9 inches into the collision bulkhead (which is buckeled)._x001C_ ICLL 66 I, 1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Accommodation/Occupational Safety
Issued 7 December 1995 Resolved
Renew the extensively wasted vent down to the emergency fire pump space._x001C_ _x001C_ _x001C_ SOLAS 60 II/65.b.ii
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Replace the wasted fuel containment boxes between #5 & 6 and 4 & 5 cargo hatches (port side). Provide mechanical plug connections and prove operation on all fuel containment boxes. Bunkering operations restricted until completed. 33 CFR 155.320.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
Repair / replace the extensively wasted cargo hold vent trunks about the main deck. 9 vents were identified with problems._x001C_ _x001C_ ICLL 66 II/19
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
Replace the port man hole cover to #4 cargo hatch as it is wasted and holed._x001C_ _x001C_ ICLL 66 II/18.1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
The deck between cargo holds #2 & 3 is badly wasted. Provide a gaging report and recommendations on repairs to be completed. Address doubler plates and holes in deck._x001C_ ICLL 66 I/1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
Replace / repair the broken lights between #2 & 3 cargo hatches (Port & stbd)._x001C_ _x001C_ SOLAS 60 II/27.a.i.1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
Remove the wooden plugs from the sounding tubes between #1 & 2 cargo holds.Most other sounding tubes have stoppers that appear corroded and unusable. Verify proper operation of all closures._x001C_ ICLL 66 II/20
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
Remove the temporary lighting in the paint locker and supply class approvedlighting. Remove electrical cables from door to allow for closure. _x001C_ _x001C_ SOLAS 60 II/27.a.i.1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
Repair the broken lighting on the forecastle bulkhead, in the forecastle space and in the fwd hydraulic pump room._x001C_ _x001C_ SOLAS 60 II/27.a.i.1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
Repair all broken vents on the forecastle bulkhead._x001C_ _x001C_ _x001C_ ICLL 66 II/19
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Deck/Cargo
Issued 7 December 1995 Resolved
Clean the hydraulic oil from the Fwd pump space._x001C_ _x001C_ _x001C_ SOLAS 60 II/65
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
In the fwd hydraulic pump space; (1) provide cover for electrical box by door, (2) remove jury rigged cable into elect box (by door), (3) remove hanging elect cable (by door), (4) remove elect wire passing through WTD toemergency fire pump space. SOLAS 60 II/27.a.i.1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Lifesaving
Issued 7 December 1995 Resolved
All ring buoy lights appear inoperable. Replace as required._x001C_ _x001C_ _x001C_ SOLAS 60 III/21.e
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Fire Fighting
Issued 7 December 1995 Resolved
Secure the leak on the fire plug, stbd of #5 cargo hatch._x001C_ _x001C_ _x001C_ SOLAS 60 II/56.d
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Remove all equipment from the port & stbd fuel containment boxes. Bunkering ops restricted until complete._x001C_ _x001C_ 33 CFR 155.320(a)(2)
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Documentation
Issued 7 December 1995 Resolved
Provide evidence of the new master on vessel prior to departure from port._x001C__x001C_ _x001C_ SOLAS 74 V/13.b
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
Hatch covers are extensively wasted and holed. Doublers added by class as temporary repair. Make permanent repairs prior to return to a U. S. port._x001C__x001C_ ICLL 66 II/15
Condition: Unknown
Due 15 December 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 7 December 1995 Resolved
Permanently repair the patched L/O line to the filters on the stbd generator engine._x001C_ _x001C_ SOLAS 60 II/26
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
Replace the L/O fill line handle to the stbd generator engine._x001C_ _x001C_ _x001C_ SOLAS 60 II/26
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
Replace all broken temperature gages on the stbd and center generator engines._x001C_ _x001C_ SOLAS 60 II/26
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Accommodation/Occupational Safety
Issued 7 December 1995 Resolved
Make permanent repairs to the disabled type II MSD. A type III MSD is alsoprovided for ship's use._x001C_ _x001C_ 33 CFR 159
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Make permanent repairs to the patched S/W pipe adjacent to the Main Engine (port, fwd) on the mid level platform._x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Lifesaving
Issued 7 December 1995 Resolved
Clean all oil from the E/R bilges, purifier room bilges and drip trays for the L/O & F/O service tanks._x001C_ _x001C_ SOLAS 60 II/65
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Repair the steam leak under the deck plates in the purifier room._x001C_ _x001C_ _x001C_ SOLAS 60 II/65
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Replace all missing engineroom valve handles per the list provided by the chief engineer._x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
Clean the oil from about the ballast valve control pump unit and repair leaks._x001C_ _x001C_ ICLL 66 II/10.1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Make permanent repairs to the three disabled temperature regulating valves on the M/E heat exchangers._x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Accommodation/Occupational Safety
Issued 7 December 1995 Resolved
Make permanent repairs to the wasted sewage lines adjacent to the stbd upper level service tanks._x001C_ _x001C_ 33 CFR 159
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Accommodation/Occupational Safety
Issued 7 December 1995 Resolved
Replace the aluminum ladder, in the steering gear space emergency escape, with a good marine quality ladder. Clear the oil drums from about the escape in the upper level stowage space._x001C_ SOLAS 60 II/54.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Accommodation/Occupational Safety
Issued 7 December 1995 Resolved
Permanently repair the lower reefer unit compressor._x001C_ _x001C_ _x001C_ ILO 147
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Deck/Cargo
Issued 7 December 1995 Resolved
Prior to loading grian cargo, repair all leaking hydraulic systems on the hatch covers. This is to include all rotary drives, locking rams and leaking crane hydraulic systems._x001C_ MARPOL 73/78 I/9.1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Deck/Cargo
Issued 7 December 1995 Resolved
Permanently repair all hydraulic leaks on the bow & stern deck machinery._x001C_ _x001C_ _x001C_ MARPOL 73/78 I/9.1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Deck/Cargo
Issued 7 December 1995 Resolved
Reconnect the disabled emergency stops on the stbd side of the aft crane._x001C_ _x001C_ _x001C_ ILO 147
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
Until the generator engines are approved by the Classification Society for safe operation, a portable electrical generator unit shall be provided and hooked to ship's power distribution system. Generator shall have minimum capacity / characteristics as shipboard generators. SOLAS 60 II/26
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
Remove all marine tape from ballast tank covers and renew wasted gaskets tomake watertight._x001C_ _x001C_ ICLL 66 18.1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Accommodation/Occupational Safety
Issued 7 December 1995 Resolved
Make permanent repairs to the evaporator ejector pump suction where patchedwith a cemebt box._x001C_ _x001C_ ILO 147
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Make permanent repairs to the outboard M/E cooling pump discharge where patched._x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Close all double bottom sounding tubes in the engineering spaces._x001C_ _x001C_ _x001C_ SOLAS 60 II/10.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Accommodation/Occupational Safety
Issued 7 December 1995 Resolved
Make permanent repairs to the leaks on the engineroom fresh water pumps (port, aft, lower level)._x001C_ _x001C_ ILO 147
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
Replace the disconnected J/W temperature sensor on the port generator engine._x001C_ _x001C_ SOLAS 60 II/26
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
Firmly secure the governor mount on the port generator engine to prevent excvessive vibration._x001C_ _x001C_ SOLAS 60 II/26
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
Make the following repairs to the Port generator engine; (1) Vibration in port, aft J/W header, (2) HP fuel injector line bypassed to rubber hose - fuel tank, (3) port, aft J/W line to header is bypassed w/ rubber hose to head tank, (4) aft oil leaks on engine. SOLAS 60 II/26
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
Renew all burned out lighting in the trunk to the emergency fire pump space._x001C_ _x001C_ SOLAS 60 II/27.a.i.1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Fire Fighting
Issued 7 December 1995 Resolved
Determine if the badly wasted emergency fire pump engine's fuel tank is adequate for continued service. Provide a class report._x001C_ _x001C_ SOLAS 60 II/65.b.ii
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Fire Fighting
Issued 7 December 1995 Resolved
Replace the missing insulation on the emergency fire pump engine exhaust line and replace the missing suction line gage._x001C_ _x001C_ SOLAS 60 II/65.b.ii
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Fire Fighting
Issued 7 December 1995 Resolved
Remove all hold back hooks from the fire doors to the engineroom and steering gear room._x001C_ _x001C_ SOLAS 60 II/54.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Fire Fighting
Issued 7 December 1995 Resolved
Remove the lines passing through the fire door to the steering gear room._x001C_ _x001C_ _x001C_ SOLAS 60 II/54.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Remove the rubber fill line to the stern tube oil head tank. Make repairs to the stern tube fittings as needed. The vessel is loosing 5-7 liters of oil per day in the stern tube._x001C_ SOLAS 60 II/54.g MARPOL 73/78 I/9.a_x001C_
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Navigation
Issued 7 December 1995 Resolved
Remove the excessive oil from about the steering gear. Provide plans for dealing with the excessive oil leaks in the future._x001C_ _x001C_ SOLAS 60 II/29.a.i
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Navigation
Issued 7 December 1995 Resolved
The magnetic stops (limit switches) on the steering gear unit appear inoperative. The rudder stock tabs run into the rams and motors race when put to hard rudder. Make permanent repairs._x001C_ SOLAS 60 II/29.a.i
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Deck/Cargo
Issued 7 December 1995 Resolved
Make repairs to the leaking hydraulic oil fitting adjacent to the deck hydraulic pump in the steering gear space. There is a bag slung under fitting holding 3-4 gal of hydraulic oil. _x001C_ SOLAS 60 II/29.a.i
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Deck/Cargo
Issued 7 December 1995 Resolved
One flange connection on the hydraulic pump (item 19) has short bolts that do not fully connect the other flange. Provide adequate bolts on flange connection._x001C_ SOLAS 60 II/56
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Repair the leaks on the two fuel oil transfer pumps and clean oil from about pumps._x001C_ _x001C_ SOLAS 60 II/54.g
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Make permanent repairs to the leaking / wasted M/E cooling line (over the port pumps). Provide a valve handle where missing._x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
Provide an adequate guard over the mounted transformer next to the OWS. A plastic bucket is not adequate._x001C_ _x001C_ SOLAS 60 II/27.a.i.1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Make permanent repairs to the general service pump where patched with liquid metal (suct side). Secure the leaks from about the packing and provide a guard over the top of rotar._x001C_ SOLAS 60 II/26
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Make permanent repairs to the stbd, aft generator overboard line. Line is extensively patched and leaking over 20-25 feet._x001C_ _x001C_ SOLAS 60 II/26_x001C_
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Make permanent repairs to the cement box patched area of the cooling line to the M/E L/O heat exchanger._x001C_ _x001C_ SOLAS 60 II/26
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Make permanent repairs to the cement box patched area on the cooling line to the M/E piston cooling heat exchanger._x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Make permanent repairs to the band patched area on the cooling line to the M/E J/W heat exchanger._x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Make permanent repairs to the M/E air box cooling line where patched (band & rubber)._x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Make permanent repairs to the center generator J/W heat exchanger where leaking._x001C_ _x001C_ SOLAS 60 II/28.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Navigation
Issued 7 December 1995 Resolved
Provide an up to date light list for the vessel._x001C_ _x001C_ _x001C_ 33 CFR 164.33(a)(2) SOLAS 74 V/20
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Navigation
Issued 7 December 1995 Resolved
Calibrate the bridge gyro repeaters with the master._x001C_ _x001C_ _x001C_ 33 CFR 164.35(e) SOLAS 74 V/12.d.ii
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Navigation
Issued 7 December 1995 Resolved
Provide instructions for operation of the emergency steering on the bridge and in the steering gear room._x001C_ _x001C_ 33 CFR 164.35(k)
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Navigation
Issued 7 December 1995 Resolved
Replace the burned out light in the magnetic steering compass._x001C_ _x001C_ _x001C_ 33 CFR 164.35(b) SOLAS 74 V/12.b.i.2
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Fire Fighting
Issued 7 December 1995 Resolved
Stbd side aft fire station valves are broken on the Capt. & Hospital decks.(WX decks)_x001C_ _x001C_ SOLAS 60 II/56.d
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
Remove the electrical lighting hazard in the hospital space._x001C_ _x001C_ _x001C_ SOLAS 60 II/27.a.i.1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Lifesaving
Issued 7 December 1995 Resolved
Arrange the stbd liferaft in a float free condition._x001C_ _x001C_ _x001C_ SOLAS 60 III/4.c
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Lifesaving
Issued 7 December 1995 Resolved
Provide a cover for the port lifeboat engine and insulate the exhaust line._x001C_ _x001C_ SOLAS 60 III/9.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
Prior to loading grain cargo, make all cargo holds available for examination by Coast Guard Boarding Officers. _x001C_ _x001C_ ICLL 66 I/1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Construction/Loadline
Issued 7 December 1995 Resolved
Determine the cause of sea water flooding in the double bottom cofferdam inthe engineroom space. Provide a class report on problem and make permanentrepairs. _x001C_ ICLL 66 I/1
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Engineering
Issued 7 December 1995 Resolved
Determine the source of the oil leak at the stern of the vessel and secure it._x001C_ _x001C_ MARPOL 73/78 I/9.a
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Electrical
Issued 7 December 1995 Resolved
Emergency lighting system operated only 2 hours when power was secured. Renew / repair emergency power system to allow operation for 6 hours._x001C_ _x001C_ SOLAS 60 II/26.a.iii
Condition: Unknown
Due 15 December 1995
Resolved 10 January 1996
Navigation
Issued 12 September 1994 Resolved
FOLLOWING CHARTS WERE NOT CORRECTED TO LATEST NOTICE TO MARINERS, #14962, 14963, 14964, 14968, 14975.
Condition: Unknown
Due 13 September 1994
Resolved 13 September 1994
Navigation
Issued 12 September 1994 Resolved
VESSEL MISSING COTP REQUIRED CHART #14966
Condition: Unknown
Due 13 September 1994
Resolved 13 September 1994
Navigation
Issued 7 September 1994 Resolved
CHART NUMBER 14884(ST MARY'S RIVER) NOT ON BOARD.
Condition: Unknown
Due 11 December 1995
Resolved 11 December 1995
Navigation
Issued 3 January 1989 Resolved
33CFR164.33(A)(1) CHARTS 11324, 11327, 11328 AND 11329 NOT CORRECTED. AUTHORITY:33USC1223 PENALTY:33USC1232
Condition: Unknown
Due 3 January 1989
Resolved 3 January 1989
Navigation
Issued 3 January 1989 Resolved
33CFR164.33(A)(2)(II) COAST GUARD LIGHT LIST VOLUME IV UNCORRECTED. AUTHORITY:33USC1223 PENALTY:33USC1232
Condition: Unknown
Due 3 January 1989
Resolved 3 January 1989
Navigation
Issued 10 August 1984 Resolved
LIGHT LIST FOR GREAT LAKES OUTDATED 46 CFR 164.33(A)2II
Condition: Unknown
Due 13 September 1994
Resolved 13 September 1994
Navigation
Issued 10 August 1984 Resolved
U.S. COAST PILOT FOR GREAT LAKES OUTDATED 46 CFR 164.33(A)2I
Condition: Unknown
Due 13 September 1994
Resolved 13 September 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.