MAURY USCG vessel records Sign in
← All vessels

ARCTIC TRADER

ARCTIC TRADER is a 1978 freight ship. The Coast Guard has recorded 7 inspections since 1986, most recently in April 1998, along with 41 deficiencies and 2 operational controls.

Records from 1986 to 1998. Most recent: inspection, 3 April 1998.

Built
1978
Last inspected
3 April 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7636731 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226146
Flag
POLAND
—
Maury page id
psix-226146

Inspections, by type

…with no type recorded7
Years with a record 4 calendar years (1986–1998)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1943 - Regulatory (Subpart C or D), Net Ton
25486 - Dead Weight, Ton
6478 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 7

3 April 1998 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 470532
15 May 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 391146
12 December 1995 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 483427
12 December 1995 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 647013
6 December 1995 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 385471
25 February 1995 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 375620
19 January 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 306498

Deficiency record · 41

Accommodation/Occupational Safety
Issued 15 May 1996 Resolved
PRIOR TO RETURN TO U.S., PROVIDE PROPER IMO APPROVAL/CERTIFICATION FOR VSL MSD. THIS REQUIREMENT WAS RE-WROTE FROM PROMS (PS95116528) DUE TO LACK OF DATE ON REQT.
Condition: Unknown
Due 15 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 15 May 1996 Resolved
PRIOR TO DEPARTURE, PROVE PROPER OPERATION OF LIFEBOAT DAVIT LIMIT SWITCHESPORT AND STBD SIDES, FORWARD AND AFT.
Condition: Unknown
Due 30 May 1996
Resolved 23 May 1996
Lifesaving
Issued 15 May 1996 Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION TO/PROVE PROPER OPERATION OF LIFEBOAT DAVITS/LIFTING GEAR (PORT AND STARBOARD SIDES).
Condition: Unknown
Due 30 May 1996
Resolved 23 May 1996
Lifesaving
Issued 15 May 1996 Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION TO THE GENERAL CONDITION OF THE STBD LIFEBOAT HULL IWO FRACTURE/TEMP REPAIR.
Condition: Unknown
Due 30 May 1996
Resolved 23 May 1996
Construction/Loadline
Issued 15 May 1996 Resolved
PRIOR TO RETURN TO U.S., REPAINT LOADLINE IN CONTRASTING COLOR WITH HULL.
Condition: Unknown
Due 30 May 1996
Resolved 23 May 1996
Construction/Loadline
Issued 15 May 1996 Resolved
PRIOR TO RETURN TO U.S., PROVIDE CLASS ATTESTATION TO SATISFACTION WITH TEMP REPAIRS IN THE FOLLOWING: (1) M/E SEAWATER COOLING LINE, (2) #3 S/S GEN COOLING LINE, (3) #1 S/W COOLING PUMP TO M/E (DISCONNECTED), (4) MECH PATCH ON BILGE LINE FWD OF SHAFT ALLEY.
Condition: Unknown
Due 15 June 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 15 May 1996 Resolved
PRIOR TO DEPARTURE, PROVIDE FIREPROOF LIFELINES FOR ALL FIRESUITS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 May 1996
Resolved 23 May 1996
Documentation
Issued 15 May 1996 Resolved
PRIOR TO DEPARTURE, PROVIDE VALID LICENSE/EXTENSION FOR MASTER'S BAHAMIAN LICENSE (OUTDATED).
Condition: Unknown
Due 30 May 1996
Resolved 23 May 1996
Fire Fighting
Issued 15 May 1996 Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION TO ARRANGEMENT OF/PROVE PROPER OPERATION OF EMERGENCY FIREPUMP.
Condition: Unknown
Due 30 May 1996
Resolved 23 May 1996
Lifesaving
Issued 15 May 1996 Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION/PROVE PROPER OPERATION OF LIFEBOAT RELEASING GEAR (PORT SIDE, RELEASING PIN) WHERE DAMAGED.
Condition: Unknown
Due 30 May 1996
Resolved 23 May 1996
Lifesaving
Issued 6 December 1995 Resolved
EMERGENCY FOOD, FIRE EXTINGUISHER AND OTHER EQUIPMENT NOT PROPERLY STOWED IN BOTH PORT AND STARBOARD LIFEBOATS.
Condition: Unknown
Due 8 December 1995
Resolved 15 December 1995
Fire Fighting
Issued 6 December 1995 Resolved
FIREMANS OUTFIT STOWED FORWARD NOT ACCESSABLE.
Condition: Unknown
Due 8 December 1995
Resolved 12 December 1995
Lifesaving
Issued 6 December 1995 Resolved
SOLAS 60, REG III/22(a)and(b). INSUFFICIENT NUMBER OF LIFE JACKETS/PERSONNEL FLOATION DEVICES. MISSING 6 AS REQUIRED BY "CARGO SAFETY EQUIPMENT" CERTIFICATE.
Condition: Unknown
Due 8 December 1995
Resolved 12 December 1995
Fire Fighting
Issued 6 December 1995 Resolved
SOLAS 60, REG I/55(c)(iii). EXCESSIVE LEAKING OF FIRE MAIN PIPING SYSTEM INENGINE ROOM.
Condition: Unknown
Due 8 December 1995
Resolved 12 December 1995
Lifesaving
Issued 6 December 1995 Resolved
HAND RAILING WELDED TO EMERGENCY FIRE PUMP EXHAUST PIPE RISER. PIPE UNINSULATED.
Condition: Unknown
Due 8 December 1995
Resolved 12 December 1995
Lifesaving
Issued 6 December 1995 Resolved
SOLAS 60, REG III/15(p). ALL FOUR LIFERAFTS IMPROPERLY INSTALLED. WEAK LINKON EACH RAFT NOT ATTACHED TO VESSEL, AND PAINTER INPROPERLY CONNECTED.
Condition: Unknown
Due 8 December 1995
Resolved 12 December 1995
Fire Fighting
Issued 6 December 1995 Resolved
SOLAS 60, REG I/55(c)(ii). EXCESSIVE LEAKING FIRE MAIN PIPING SYSTEM AT STARBOARD AFT FIRE STATION.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Navigation
Issued 6 December 1995 Resolved
WARNING STATEMENT NOT ON BOTTOM OF MANEUVERING FACT SHEET
Condition: Unknown
Due 8 December 1995
Resolved 9 December 1995
Accommodation/Occupational Safety
Issued 6 December 1995 Resolved
M.S.D. INOPERABLE, "Y'" VALVE NOT SECURED
Condition: Unknown
Due 6 December 1995
Resolved 9 December 1995
Documentation
Issued 6 December 1995 Resolved
ENTRIES NOT PROPERLY MADE. INCOMPLETE PAGES NOT LINED OUT.
Condition: Unknown
Due 8 December 1995
Resolved 9 December 1995
Documentation
Issued 6 December 1995 Resolved
COMPLETED PAGES NOT SIGNED IN OIL RECORD BOOK
Condition: Unknown
Due 8 December 1995
Resolved 9 December 1995
Navigation
Issued 6 December 1995 Resolved
STERN RUNNING LIGHT NOT DISPLAYED. AFT MAST/STAFF STERN LIGHT IS ATTACHED TO IS LYING ON DECK.
Condition: Unknown
Due 8 December 1995
Resolved 12 December 1995
Construction/Loadline
Issued 6 December 1995 Resolved
GROSS ACCUMULATION OF OIL IN MACHINERY SPACE BILGES; ON MACHINERY, AND DECKING IN ENGINE ROOM AROUND MACHINERY.
Condition: Unknown
Due 8 December 1995
Resolved 12 December 1995
Fire Fighting
Issued 6 December 1995 Resolved
FIRE EXTINGUISHER IN AFTER STEERING LYING ON THE DECK, NO BRACKET IN SPACE FOR THE EXTINGUISHER.
Condition: Unknown
Due 8 December 1995
Resolved 12 December 1995
Fire Fighting
Issued 6 December 1995 Resolved
SOLAS 60, REG II/65(a). EMERGENCY FIRE PUMP UNABLE TO PROVIDE EFFECTIVE FIRE STREAM.
Condition: Unknown
Due 8 December 1995
Resolved 12 December 1995
Accommodation/Occupational Safety
Issued 6 December 1995 Resolved
M.S.D. NOT LABELED. UNKNOWN WHAT TYPA DEVICE.
Condition: Unknown
Due 15 May 1996
Resolved 23 May 1996
Navigation
Issued 6 December 1995 Resolved
RUDDER ANGLE INDICATOR REPEATER NOT SHOWING TRUE RUDDER POSITION_x001C_
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Lifesaving
Issued 6 December 1995 Resolved
SOLAS 60, REG III/26(a)(ii). EMERGENCY DRILLS NOT CONDUCTED. _x001C_ DRILLS REQUIRED MONTHLY. ENTIRE CREW CHANGE ON 16 NOV 95. WHEN ENTIRE CREW CHANGED, DRILLS REQUIRED TO BE CONDUCTED WITHIN 24 HOURS.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Lifesaving
Issued 6 December 1995 Resolved
SOLAS 60, REG III/4(c). CREW UNFAMILIAR WITH LAUNCH PROCEEDURE OF EMERGENCYLIFE BOAT. TOOK OVER ONE HOUR TO MOVE BOAT OUT OF CRADLE TO THE RAIL.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Lifesaving
Issued 6 December 1995 Resolved
BOTH LIMIT SWITCHES ON PORT EMERGENCY LIFE BOAT FALLS/DAVITS FAILED.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Lifesaving
Issued 6 December 1995 Resolved
SOLAS 60/ REG III/5(b)(i). STARBOARD LIFEBOAT, PORT AFT HATCH MISSING SECURING DOG.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Electrical
Issued 6 December 1995 Resolved
DECK LIGH EXTENDING FROM STARBOARD BULKHEAD BY RAMP TO LIFEBOAT WASTER THROUGH. BRACKET/FIXTURE HELD TOGETHER WITH BAILING WIRE.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Deck/Cargo
Issued 6 December 1995 Resolved
FORWARD CARGO MAST, STARBOARD STAY WASTED. PIECE OF BROKEN STAY HANGING FROM MAST TOP, REMAINING PIECE OF STAY ON DECK.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Deck/Cargo
Issued 6 December 1995 Resolved
POWER CONTROL BOX FOR PORT WINDLESS TORN FROM DECK.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Electrical
Issued 6 December 1995 Resolved
SOLAS 60, REG II/27(a)(i)ELECTRICAL HAZARDS AT #2 GENERATOR CONTROL BOX, VARIOUS LOCATIONS THROUGHOUT ENGINE ROOM, STEERING SPACE AND HOUSE. ELECTRICAL JUNCTION BOXES NOT COVERED.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Navigation
Issued 6 December 1995 Resolved
COPY OF INLAND NAVIGATION RULES NOT ONBOARD
Condition: Unknown
Due 8 December 1995
Resolved 9 December 1995
Deck/Cargo
Issued 6 December 1995 Resolved
NO OIL DISCHARGE PLACARD
Condition: Unknown
Due 8 December 1995
Resolved 9 December 1995
Navigation
Issued 19 January 1986 Resolved
THE VESSEL DID NOT HAVE A SIMPLE BLOCK DIAGRAM AND OPERATING INSTRUCTIONS FOR CHANGE OVER OF EMERGENCY STEERING POSTED ON THE BRIDGE
Condition: Unknown
Due 19 January 1986
Resolved 19 January 1986
Documentation
Issued 19 January 1986 Resolved
VESSEL HAD NO OIL TRANSFER PROCEDURES ON BOARD
Condition: Unknown
Due 19 January 1986
Resolved 19 January 1986
Documentation
Issued 19 January 1986 Resolved
THE VESSEL DID NOT HAVE A LIST OF PERSONS IN CHARGE OF OIL TRANSFER OPERATIONS
Condition: Unknown
Due 19 January 1986
Resolved 19 January 1986
Navigation
Issued 19 January 1986 Resolved
THE VESSEL DID NOT HAVE A CURRENT COPY OF THE U.S. COAST PILOT OR A FOREIGNEQUIVALENT ON BOARD
Condition: Unknown
Due 25 February 1995
Resolved 2 March 1995

Ownership record