TUAPSE is a 1979 tank ship. The Coast Guard has recorded 20 inspections since 1997, most recently in April 2003, along with 22 deficiencies and 3 operational controls, 1 with no removal date recorded.

Records from 1997 to 2003. Most recent: inspection, 18 April 2003.

Built
1979
Last inspected
18 April 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7636793 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226149
Flag
SOVIET UNION
—
Maury page id
psix-226149

Inspections, by type

…with no type recorded11
Years with a record 7 calendar years (1997–2003)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it23876 - Dead Weight, Metric Ton
31000 - Displacement, Metric Ton
8738 - Regulatory (Subpart C or D), Net Ton
14550 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

18 April 2003 Certificate of Compliance
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1776074
18 April 2003 Special Interest Vessel
Type not classified · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1776159
18 April 2003 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1776366
17 April 2003 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1786798
7 November 2002 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1702118
30 September 2002 Special Interest Vessel
Type not classified · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1682126
12 July 2002 Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1645397
12 April 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1603941
6 March 2002 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1492036
5 March 2002 Certificate of Compliance · Security Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1490481
25 April 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 289461
25 February 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 287392
18 April 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 276290
16 April 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 132789
7 April 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 80954
21 February 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 274674
16 November 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 434789
23 November 1998 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 422853
25 November 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 410234
25 November 1997 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1409790

Deficiency record · 22

Engineering › Generator (propulsion/auxiliary-electric)
Issued 12 July 2002 Resolved
Emergency Generator water pump seal is leaking.
Action required: 705 - Other - as specified
Due 11 August 2002
Resolved 6 November 2002
Resolution: Recieved class report attesting to repair
Lifesaving › Launching Appliances
Issued 5 March 2002 Resolved
Forward release gear for port lifeboat does not operate properly. SOLAS 74 (amended) Ch.III, Reg 19.2 LEGACY COMPONENT DESC: Release Mechanism
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2002
Resolved 6 March 2002
Resolution: Vessel crew cleaned release gear of excess paint and corrosion.
Fire Fighting › Structural - A Class Divisions
Issued 5 March 2002 Resolved
Fire doors in stairwell do not close properly. SOLAS 60, Ch II, Reg 38(e) LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2002
Resolved 6 March 2002
Resolution: Vessel crew adjusted doors to ensure proper closure.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 5 March 2002 Resolved
Lighting in crew deck shower facility does not work. ILO 147 LEGACY COMPONENT DESC: Shower/Bathtub
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 March 2002
Resolution: Light fixture replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 5 March 2002 Resolved
Standard dischage connection missing. 33 CFR 155.430 LEGACY COMPONENT DESC: Adapters
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 March 2002
Lifesaving › Lifeboat
Issued 5 March 2002 Resolved
Outboard doors for port lifeboat do not open. SOLAS 74 (amended) Ch III, Reg 19.2 LEGACY COMPONENT DESC: Embarkation/Disembarkation Capabilities
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2002
Resolved 6 March 2002
Resolution: Door hinges were cleaned of excess paint and corrosion.
Deck/Cargo › Holds/Tanks
Issued 5 March 2002 Resolved
Flame screen for port, forward fuel oil tank damaged. 46 CFR 32.55-20(d)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2002
Resolved 6 March 2002
Resolution: New screen put in place.
Deck/Cargo
Issued 25 February 2001 Resolved
TEMPORARY FITTING INSTALLED ON SLOP LINE LOCATED MID LEVEL IN CARGO PUMP ROOM. PROVIDE APPROVAL FROM CLASS OR MAKE PERMANENT PRIOR TO NEXT U.S. PORT._x001C_ CLASS ISSUED COC TO BE COMPLETED NLT 25MAR01
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Deck/Cargo
Issued 25 February 2001 Resolved
VESSEL DOES NOT HAVE THE REQUIRED AMOUNT OF OIL ABSORBANT MATERIAL. _x001C_ PROVIDE THE REQUIRED SPILL EQUIPMENT AS PER 33 CFR 155.205 PRIOR TO BUNKERING OR OIL CARGO OPERATIONS IN U.S. WATERS. _x001C_
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Engineering
Issued 25 February 2001 Resolved
NO.2 GENERATOR'S NO.1 F/O INJECTION PUMP LEAKING. REPAIR TO SATISFACTION OFCLASS BY 02MAR01._x001C_
Condition: Unknown
Due 2 March 2001
Resolved 5 March 2001
Deck/Cargo
Issued 25 February 2001 Resolved
VESSEL COULD NOT PRODUCE ORIGINAL PROCEDURES AND ARRANGEMENTS MANUAL. PROVIDE ORIGINAL APPROVED PROCEDURES AND ARRANGEMENTS MANUAL BY NEXT U.S. PORT._x001C_
Condition: Unknown
Due 1 March 2001
Resolved 5 March 2001
Deck/Cargo
Issued 25 February 2001 Resolved
VESSEL DOES NOT HAVE THE REQUIRED EMERGENCY LIGHTERING EQUIPMENT ONBOARD. PROVIDE EQUIPMENT IAW 33 CFR 155.410 PRIOR TO CARRIAGE OF OIL IN U.S. WATERS_x001C_
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Construction/Loadline
Issued 25 February 2001 Resolved
EXCESSIVE OIL IN BILGES AND ON ALL MACHINERY IN ENGINE AND GENERATOR ROOMS.REMOVE ALL OIL FROM MACHINERY AND BILGES BY NEXT U.S. PORT._x001C_
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Navigation
Issued 25 February 2001 Resolved
EXCESSIVE OIL IN CATCH BASINS AND ON DECKS IN STEERING COMPARTMENT. _x001C_ REMOVE ALL OIL BY NEXT U.S. PORT._x001C_
Condition: Unknown
Due 4 March 2001
Resolved 5 March 2001
Accommodation/Occupational Safety
Issued 25 February 2001 Resolved
VESSEL'S SEWAGE TREATMENT PLANT IS NOT OPERATIONAL. REPAIR TO SATISFACTION OF CLASS BY NEXT U.S. PORT AND VESSEL IS PROHIBITED FROM OPERATING _x001C_ SEWAGE PLANT IN US WATERS UNTIL IT IS INSPECTED BY A CG MARINE INSPECTOR_x001C_ CLASS ISSUED COC TO BE COMPLETED NLT 25MAR01.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Construction/Loadline
Issued 25 February 2001 Resolved
ENTRY WAY INTO AFT FOAM ROOM FILLED WITH CEMENT PATCH. (SOLAS 74A I/11)_x001C_ PROVIDE CLASS REPORT APPROVING PATCH OR REMOVE AND REPAIR BY NEXT U.S. PORT_x001C_ CLASS ISSUED COC TO BE COMPLETED NLT 25MAR01.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Engineering
Issued 25 February 2001 Resolved
MAIN ENGINE NO.'S 5&6 CYLINDER F/O INJECTION PUMPS LEAKING AT DISTRIBUTION BLOCK. REPAIR TO SATISFACTION OF CLASS BY 02MAR01._x001C_
Condition: Unknown
Due 4 March 2001
Resolved 5 March 2001
Deck/Cargo
Issued 25 February 2001 Resolved
TEMPORARY REPAIR WAS FOUND ON NO.1 CARGO PUMP SEPERATOR LINE. REPAIR LINE PERMANENTLY TO SATISFACTION OF CLASS BY NEXT U.S. PORT_x001C_ _x001C_ CLASS ISSUED COC TO BE COMPLETED NLT 25MAR01.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Engineering
Issued 25 February 2001 Resolved
NO.2 GENERATOR HAS NUMEROUS CYLINDER HEAD COOLING WATER LEAKS. _x001C_ REPAIR TO SATISFACTION OF CLASS BY 07MAR01_x001C_
Condition: Unknown
Due 7 March 2001
Resolved 5 March 2001
Engineering
Issued 25 February 2001 Resolved
NO.1 GENERATOR HAS EXCESSIVE EXHAUST LEAKS._x001C_ REPAIR TO SATISFACTION OF CLASS BY 02MAR01._x001C_
Condition: Unknown
Due 2 March 2001
Resolved 5 March 2001
Deck/Cargo
Issued 23 November 1998 Resolved
Wastage/leaking in #4 center & #4 port tanks. Vessel to repair tank wastage to satisfaction of class & provide survey report to CG prior to departure. _x001C_ SOLAS 74 (ammended) REG II-2/21
Condition: Unknown
Due 27 November 1998
Resolved 11 December 1998
Fire Fighting
Issued 23 November 1998 Resolved
Repair emergency fire pump to satisfaction of class society, and provide survey report to COTP prior to departure.
Condition: Unknown
Due 27 November 1998
Resolved 11 December 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.