Records from 1984 to 2000. Most recent: inspection, 25 October 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
25 October 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 283600
13 April 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 414848
28 August 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 394746
28 March 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 389460
26 May 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 378985
4 May 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 378047
16 March 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 356982
6 September 1990
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 339429
5 July 1989
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 331273
10 August 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 494745
19 February 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 501799
7 October 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 311884
12 November 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 305249
17 July 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 302991
19 July 1984
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 297036
Construction/Loadline › Markings › Load Line Mark
Issued 25 October 2000
Resolved
Amended requirement (PS98034569-SJ03) issued 13 APR 98, eliminate obsolete loadline markings, prior to next U.S. port.
Condition: Unknown
Due 25 October 2000
Resolved 7 October 2004
Resolution: 07OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Deck/Cargo
Issued 13 April 1998
Resolved
PROVIDE A FIXED CONTAINER OR ENCLOSED DECK AREA UNDER OR AROUND BULK LUBRICATING OIL FILL PIPES IN ACCORDANCE WITH 33CFR155.320(a).
Condition: Unknown
Due 30 October 2000
Resolved 30 October 2000
Construction/Loadline › Markings › Load Line Mark
Issued 13 April 1998
Resolved
ELIMINATE OBSOLETE LOADLINE MARKINGS.
Condition: Unknown
Due 13 May 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Electrical
Issued 13 April 1998
Resolved
PROVIDE INSULATION TO HANDLES FOR THE ELECTRICAL PANEL AT CONTROL ROOM.
Condition: Unknown
Due 30 October 2000
Resolved 30 October 2000
Navigation
Issued 28 August 1996
Resolved
SHIP RADIO TUNING IS INOPERABLE. RADIO WORKS ONLY IN CH16. REPAIR PRIOR TODEPARTURE.
Condition: Unknown
Due 4 September 1996
Resolved 6 September 1996
Lifesaving
Issued 28 March 1996
Resolved
LIFEJACKET/IMMERSION SUIT LIGHT BATTERIES EXPIRED. _x001C_ S0LAS 74 AMMEND. CH.III, REG.27.2
Condition: Unknown
Due 28 March 1996
Resolved 29 March 1996
Fire Fighting
Issued 28 March 1996
Resolved
SCBA AIR SUPPLYING SYSTEM MALFUNCTIONING._x001C_ SOLAS 74 AMMEND. CH.II, REG. 17.3 CORRECT PRIOR TO DEPARTURE.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Documentation
Issued 28 March 1996
Resolved
OIL TRANSFER PROCEDURES NOT COMPLETE. PROVIDE PRIOR TO BUNKERING. 33 C.F.R. 155.720-760.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Engineering
Issued 28 March 1996
Resolved
CLASS SOCIETY TO ENSURE OIL WATER SEPARATOR OPERATES PROPERLY. ELSE, RETAINALL OILY WASTE ON BOARD. _x001C_ 33 C.F.R.155.380
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Documentation
Issued 28 March 1996
Resolved
PERMANENTLY MARK FREEBOARD MARK I.A.W. INTERNATIONAL CONVENTION OF LOAD LINES.
Condition: Unknown
Due 29 August 1996
Resolved 29 August 1996
Documentation
Issued 4 May 1995
Resolved
IMPROPER ENTRIES IN OIL RECORD BOOK; MISSING START AND STOP POSITIONS FROM 15 PPM OWS ACCORDING TO OIL RECORD BOOK INSTRUCTIONS.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Documentation
Issued 16 March 1993
Resolved
EACH COMPLETED PAGE IN THE OIL RECORD BOOK WAS NOT SIGNED BY MASTER.
Condition: Unknown
Due 16 March 1993
Resolved 17 March 1993
Navigation
Issued 5 July 1989
Resolved
TIDAL CURRENT TABLE FOR THE SAVANNAH AREA NOT ON BOARD.
Condition: Unknown
Due 5 July 1989
Resolved 5 July 1989
Documentation
Issued 17 July 1985
Resolved
ANNUAL SURVEY TO THE SOLAS CONSTRUCTION CERTIFICATE DUE IN JUNE 85, WAS NOT DONE.
Condition: Unknown
Due 12 November 1985
Resolved 17 July 1985
Documentation
Issued 17 July 1985
Resolved
ANNUAL LOADLINE SURVEY DUE IN JUNE 85 HAS NOT BEEN DONE A VIOLATION OF 46 CFR 42,09-1(B).
Condition: Unknown
Due 12 November 1985
Resolved 17 July 1985
Documentation
Issued 17 July 1985
Resolved
REQUIRED ANNUAL SURVEY FOR THE IOPP CERTIFICATE DUE JUNE 85, HAS NOT BEEN DONE A VIOLATION OF 33 CFR 151.19 (B).
Condition: Unknown
Due 12 November 1985
Resolved 17 July 1985