MAURY USCG vessel records Sign in
← All vessels

AQUA MARINA

AQUA MARINA is a 1979 freight ship. The Coast Guard has recorded 24 inspections since 1986, most recently in October 2010, along with 25 deficiencies and 5 operational controls.

Records from 1986 to 2010. Most recent: inspection, 4 October 2010.

Built
1979
Last inspected
4 October 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7640483 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226202
Flag
PANAMA
—
Maury page id
psix-226202

Inspections, by type

…with no type recorded12
Years with a record 11 calendar years (1986–2010)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it17169 - Dead Weight, Metric Ton
21589 - Displacement, Metric Ton
6259 - Convention (Subpart B), Net Ton
10230 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

4 October 2010 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3862698
9 September 2010 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3846283
10 June 2008 Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3232681
27 February 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2878689
25 February 2007 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2877296
23 February 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2876442
25 May 2006 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2658473
19 May 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2653619
17 May 2006 Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2651362
21 January 2005 Spot Check · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2275705
13 January 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2276799
9 October 2004 PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2217305
12 August 2004 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2167859
25 July 2004 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2143273
5 June 2003 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1805682
3 December 2002 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1714226
15 October 2002 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1689615
16 October 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 333130
12 October 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 333074
5 June 1989 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 330711
29 March 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 464750
20 June 1988 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 324022
6 December 1986 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 500751
5 July 1986 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 526612

Deficiency record · 25

Navigation › Collision/Grounding Avoidance › Radar
Issued 27 February 2007 Resolved
Secondary radar is inoperable. On 28FEB2007, Sector San Juan received a flag state letter from Panama authorizing the AQUA MARINA to sail until 15APR2007 without the secondary radar operating.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 April 2007
Resolved 11 June 2008
Resolution: Conducted check during inspection.
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 February 2007 Resolved
Inoperative Radar (Tokyo Keiki MR-12000-E)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2008
Resolution: Conducted check during inspection.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 17 May 2006 Resolved
Vessel's emergency fire pump is not operational. The electic motor for the pump was removed on 21 APR 06 and has been operating without permission from Flag state or Class Society. Flag state administration or representative to attest to the proper operation of the emergency fire pump prior to departure. Violation of SOLAS 60 II / 65.b.ii.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2006
Resolved 21 May 2006
Resolution: Flag attested the installation of the motor on the emergency fire pump.
Lifesaving › Launching Appliances › Davit
Issued 17 May 2006 Resolved
Break for the port lifeboat davit did not work properly when tested when the break handle was released from the remote operation station the break was not applied and the lifeboat continued to descend. Flag State Administration or representative to attest to proper operation of both port and starboard lifeboats. Violation of SOLAS 74A III/16.1 LSA Code 6.1.2.12
Due 31 May 2006
Resolved 25 May 2006
Resolution: Received report attesting to the proper operation of lifeboat davit break, witnessed by Flag Administration (Panama).
Lifesaving › Lifeboat Equipment › Food Ration
Issued 17 May 2006 Resolved
Replace 02 damaged food rations in the starboard lifeboat (air tight seal was broken). Violation of SOLAS 74A III/34 LSA Code 4.4.8.12. Rectify prior to departure to the satisfaction of the Coast Guard. Coast Guard will accept fax receipt of food rations.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2006
Resolved 18 May 2006
Resolution: Recived recept attesting the purchase of food rations.
Lifesaving › Lifeboat › Markings
Issued 17 May 2006 Resolved
Number of persons on both port and starboard lifeboats does not match the Safety Equip. Certificate (SEC). SEC states 27 persons and lifeboats are marked 30 persons. Violation of SOLAS 74A III/34 LSA COde 4.4.7.1
Action required: 705 - Other - as specified
Due 17 June 2006
Resolved 25 May 2006
Resolution: Witnessed proper markings of vessel''''s lifeboat personnel allowance.
Construction/Loadline › Structures › Door
Issued 17 May 2006 Resolved
Emergency escape hatch (watertight door) for the port side pipe tunnel forward, dogs do not properly seal and secure the hatch. Violation of ICLL66 Reg 12
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 25 May 2006
Resolution: Received Classification report, from Russian Maritime Register of Shipping, attesting to the repairs made to the aforementioned escape hatch.
Deck/Cargo › Cargo Stowage › General
Issued 17 May 2006 Resolved
Hatch coaming stiffners at aft port corners of cargo hold 2 & 4 are fractured. Class society surveyour to attest to proper repairs. Violation of SOLAS 74A II-I/3-1
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 25 May 2006
Resolution: Received Classification report, from Russian Maritime Register of Shipping, attesting to the repairs made to aforementioned stiffeners.
Documentation › Certificates/Documents › IOPP Certificate
Issued 17 May 2006 Resolved
Specifications of the bilge tank are not indicated on the IOPP certificate. Class surveyour to attest to proper bilge tank arrangement and notation on the IOPP. Violation of MARPOL Annex I /Reg 7.
Action required: 705 - Other - as specified
Due 17 June 2006
Resolved 25 May 2006
Resolution: Received report, from Flag Administration (Panama), of proper corrections made to vessel''''s IOPP.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (100 ppm)
Issued 17 May 2006 Resolved
Sampling tube to oil content meter on the OWS is bent and crimped in two locations restricting the flow to tthe meter. Class surveyour to attest to proper operation of the OWS and oil content meter. OWS not to be used in US waters until corrected. Violation of MARPOL Annex I / Reg 16. Rectify prior to next US port to the statisfaction of class.
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 25 May 2006
Resolution: Received report of proper repairs made to Oily Water Separator sampling tube, and the subsequent satisfactory operation of the system. Repairs witnessed by Flag Administration, (Panama).
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (100 ppm)
Issued 17 May 2006 Resolved
The posted operating procedures for the OWS are not correct and need to reflect the new Oil Content meter procedures. SOLAS 74A IX / 3. ISM Code II.
Action required: 705 - Other - as specified
Due 17 June 2006
Resolved 25 May 2006
Resolution: Received report attesting to the proper operating instructions posted by crew, witnessed by Flag Administration, (Panama).
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 17 May 2006 Resolved
Inoperable emergency fire pump was not reported as a non-conformity as per the vessel's safety management system. Violation of SOLAS 74 A IX/3.
Action required: 705 - Other - as specified
Due 17 May 2006
Resolved 17 May 2006
Resolution: Vessel''s captain sent non-conformity report to the company in the presence of Coast Guard boarding team.
Engineering › Diesel Engine (auxiliary) › Connecting Rod
Issued 25 July 2004 Resolved
The Main Diesel Generator has a minor F/O leak at the bottom suct valve push rod for the No. 1 cylinder. Repair F/O leak by 26-JUl-2004 to the satisfaction of the Coast Guard.
Action required: 705 - Other - as specified
Due 26 July 2004
Resolved 26 July 2004
Resolution: 26 Jul 04: Received proper documentation from the Master of the vessel stating that the deficiency has been rectified.
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 25 July 2004 Resolved
The Chief Engineer and the Third Engineer could not produce their national Greek licenses that are referred to by their Panamanian Flag State endorsements. Provide proof of the C/E and 3/E national Greek licenses by 26-Jul-04 to the satisfaction of the Coast Guard.
Action required: 705 - Other - as specified
Due 26 July 2004
Resolved 26 July 2004
Resolution: 26 Jul 04: Received the proper documentation from the Panama Maritime Authority clearing the issued deficiency.
Pollution Prevention/Response › Prevention Equipment
Issued 15 October 2002 Resolved
REPAIR TO ORIGINAL CONTAINMENT AREA OF FUEL OIL VENT LOCATED ON PORTSIDE BOW CONTAINMENT AREA IS CRACKED AND WASTED. LEGACY COMPONENT DESC: Fixed Containment
Condition: Unknown
Due 15 November 2002
Resolved 3 December 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 15 October 2002 Resolved
PROPERLY STOW ALL COMPRESSED GAS BOTTLES LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Due 15 November 2002
Resolved 3 December 2002
Resolution: GAS BOTTLES WERE STOWED PROPERLY.
Fire Fighting › Means of Escape
Issued 15 October 2002 Resolved
PROVIDE PROPER EMER. ESCAPE ROUTE SIGNAGE IN ENGINE ROOM SPACES SOLAS 60, III/68(b)(ii) LEGACY COMPONENT DESC: Escape Route Signs
Condition: Unknown
Due 15 November 2002
Resolved 3 December 2002
Resolution: EMERGENCY ESCAPE CLEARLY MARKED.
Construction/Loadline › Markings
Issued 15 October 2002 Resolved
PERM. MARK LOADLINE IAW LOADLINE CERTIFICATE TO SATISFACTION OF CLASS LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 3 December 2002
Resolution: LOADLINE CLEARLY MARKED ON HULL.
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 15 October 2002 Resolved
REPLACE/REPAIR MISSING ELECTRICAL PANELS TO REEFER UNITS IN GALLEY STORES SOLAS 60, III/36
Condition: Unknown
Due 15 November 2002
Resolved 3 December 2002
Resolution: ELECTRICAL PANELES ON REFFER UNITS INSTALLED PROPERLY.
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 15 October 2002 Resolved
REMOVE ALL NON-ESSENTIAL ITEMS IN FOOD PREPARATION AREA IN GALLEY STORES ILO 147
Condition: Unknown
Due 15 November 2002
Resolved 3 December 2002
Resolution: FOOD PREPARATION AREA IN GOOD ORDER.
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 15 October 2002 Resolved
REINSTALL SWITCHES/SENSORS TO DOORS OF COLD STORES ILO 147
Condition: Unknown
Due 15 November 2002
Resolved 3 December 2002
Resolution: SWITCHES WORKING PROPERLY.
Lifesaving › Launching Appliances
Issued 15 October 2002 Resolved
REPAIR HYDRAULIC LEAK TO STARBOARD BOAT DAVIT TO SATISFACTION OF CLASS SOLAS 60, III/36 LEGACY COMPONENT DESC: Davit
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 3 December 2002
Resolution: LEAKING PIPES WERE REPLACED.
Documentation
Issued 5 June 1989 Resolved
MISSING OIL TRANSFER PROCEDURES AS REQUIRED BY 33CFR155.750.
Condition: Unknown
Due 5 June 1989
Resolved 5 June 1989
Unknown
Issued 5 June 1989 Resolved
MSD NOT LABELLED AS REQUIRED BY 33CFR159.7.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 5 June 1989 Resolved
MISSING 3 CHARTS 14912, 14911, AND 14928 AS REQUIRED BY 33CFR164.33(A)(1).
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.