← All vessels
AQUA MARINA
AQUA MARINA is a 1979 freight ship. The Coast Guard has recorded 24 inspections since 1986, most recently in October 2010, along with 25 deficiencies and 5 operational controls.
Records from 1986 to 2010. Most recent: inspection, 4 October 2010.
- Built
- 1979
- Last inspected
- 4 October 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 25 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7640483 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HOES
226202
Flag
PANAMA
—
Maury page id
psix-226202
Inspections, by type
The 24 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it17169 - Dead Weight, Metric Ton
21589 - Displacement, Metric Ton
6259 - Convention (Subpart B), Net Ton
10230 - Convention (Subpart B), Gross Ton
21589 - Displacement, Metric Ton
6259 - Convention (Subpart B), Net Ton
10230 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 24
4 October 2010
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3862698
9 September 2010
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3846283
10 June 2008
Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3232681
27 February 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2878689
25 February 2007
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2877296
23 February 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2876442
25 May 2006
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2658473
19 May 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2653619
17 May 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2651362
21 January 2005
Spot Check · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2275705
13 January 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2276799
9 October 2004
PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2217305
12 August 2004
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2167859
25 July 2004
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2143273
5 June 2003
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1805682
3 December 2002
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1714226
15 October 2002
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1689615
16 October 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 333130
12 October 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 333074
5 June 1989
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 330711
29 March 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 464750
20 June 1988
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 324022
6 December 1986
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 500751
5 July 1986
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 526612
Deficiency record · 25
Navigation › Collision/Grounding Avoidance › Radar
Issued 27 February 2007
Resolved
Secondary radar is inoperable. On 28FEB2007, Sector San Juan received a flag state letter from Panama authorizing the AQUA MARINA to sail until 15APR2007 without the secondary radar operating.
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 February 2007
Resolved
Inoperative Radar (Tokyo Keiki MR-12000-E)
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 17 May 2006
Resolved
Vessel's emergency fire pump is not operational. The electic motor for the pump was removed on 21 APR 06 and has been operating without permission from Flag state or Class Society. Flag state administration or representative to attest to the proper operation of the emergency fire pump prior to departure. Violation of SOLAS 60 II / 65.b.ii.
Lifesaving › Launching Appliances › Davit
Issued 17 May 2006
Resolved
Break for the port lifeboat davit did not work properly when tested when the break handle was released from the remote operation station the break was not applied and the lifeboat continued to descend. Flag State Administration or representative to attest to proper operation of both port and starboard lifeboats. Violation of SOLAS 74A III/16.1 LSA Code 6.1.2.12
Lifesaving › Lifeboat Equipment › Food Ration
Issued 17 May 2006
Resolved
Replace 02 damaged food rations in the starboard lifeboat (air tight seal was broken). Violation of SOLAS 74A III/34 LSA Code 4.4.8.12. Rectify prior to departure to the satisfaction of the Coast Guard. Coast Guard will accept fax receipt of food rations.
Lifesaving › Lifeboat › Markings
Issued 17 May 2006
Resolved
Number of persons on both port and starboard lifeboats does not match the Safety Equip. Certificate (SEC). SEC states 27 persons and lifeboats are marked 30 persons. Violation of SOLAS 74A III/34 LSA COde 4.4.7.1
Construction/Loadline › Structures › Door
Issued 17 May 2006
Resolved
Emergency escape hatch (watertight door) for the port side pipe tunnel forward, dogs do not properly seal and secure the hatch. Violation of ICLL66 Reg 12
Deck/Cargo › Cargo Stowage › General
Issued 17 May 2006
Resolved
Hatch coaming stiffners at aft port corners of cargo hold 2 & 4 are fractured. Class society surveyour to attest to proper repairs. Violation of SOLAS 74A II-I/3-1
Documentation › Certificates/Documents › IOPP Certificate
Issued 17 May 2006
Resolved
Specifications of the bilge tank are not indicated on the IOPP certificate. Class surveyour to attest to proper bilge tank arrangement and notation on the IOPP. Violation of MARPOL Annex I /Reg 7.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (100 ppm)
Issued 17 May 2006
Resolved
Sampling tube to oil content meter on the OWS is bent and crimped in two locations restricting the flow to tthe meter. Class surveyour to attest to proper operation of the OWS and oil content meter. OWS not to be used in US waters until corrected. Violation of MARPOL Annex I / Reg 16. Rectify prior to next US port to the statisfaction of class.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (100 ppm)
Issued 17 May 2006
Resolved
The posted operating procedures for the OWS are not correct and need to reflect the new Oil Content meter procedures. SOLAS 74A IX / 3. ISM Code II.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 17 May 2006
Resolved
Inoperable emergency fire pump was not reported as a non-conformity as per the vessel's safety management system. Violation of SOLAS 74 A IX/3.
Engineering › Diesel Engine (auxiliary) › Connecting Rod
Issued 25 July 2004
Resolved
The Main Diesel Generator has a minor F/O leak at the bottom suct valve push rod for the No. 1 cylinder. Repair F/O leak by 26-JUl-2004 to the satisfaction of the Coast Guard.
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 25 July 2004
Resolved
The Chief Engineer and the Third Engineer could not produce their national Greek licenses that are referred to by their Panamanian Flag State endorsements. Provide proof of the C/E and 3/E national Greek licenses by 26-Jul-04 to the satisfaction of the Coast Guard.
Pollution Prevention/Response › Prevention Equipment
Issued 15 October 2002
Resolved
REPAIR TO ORIGINAL CONTAINMENT AREA OF FUEL OIL VENT LOCATED ON PORTSIDE BOW CONTAINMENT AREA IS CRACKED AND WASTED. LEGACY COMPONENT DESC: Fixed Containment
Accommodation/Occupational Safety › Occupational Safety
Issued 15 October 2002
Resolved
PROPERLY STOW ALL COMPRESSED GAS BOTTLES LEGACY COMPONENT DESC: Guards for Exposed Hazards
Fire Fighting › Means of Escape
Issued 15 October 2002
Resolved
PROVIDE PROPER EMER. ESCAPE ROUTE SIGNAGE IN ENGINE ROOM SPACES
SOLAS 60, III/68(b)(ii) LEGACY COMPONENT DESC: Escape Route Signs
Construction/Loadline › Markings
Issued 15 October 2002
Resolved
PERM. MARK LOADLINE IAW LOADLINE CERTIFICATE TO SATISFACTION OF CLASS LEGACY COMPONENT DESC: Load Line Mark
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 15 October 2002
Resolved
REPLACE/REPAIR MISSING ELECTRICAL PANELS TO REEFER UNITS IN GALLEY STORES
SOLAS 60, III/36
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 15 October 2002
Resolved
REMOVE ALL NON-ESSENTIAL ITEMS IN FOOD PREPARATION AREA IN GALLEY STORES
ILO 147
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 15 October 2002
Resolved
REINSTALL SWITCHES/SENSORS TO DOORS OF COLD STORES
ILO 147
Lifesaving › Launching Appliances
Issued 15 October 2002
Resolved
REPAIR HYDRAULIC LEAK TO STARBOARD BOAT DAVIT TO SATISFACTION OF CLASS
SOLAS 60, III/36 LEGACY COMPONENT DESC: Davit
Documentation
Issued 5 June 1989
Resolved
MISSING OIL TRANSFER PROCEDURES AS REQUIRED BY 33CFR155.750.
Unknown
Issued 5 June 1989
Resolved
MSD NOT LABELLED AS REQUIRED BY 33CFR159.7.
Navigation
Issued 5 June 1989
Resolved
MISSING 3 CHARTS 14912, 14911, AND 14928 AS REQUIRED BY 33CFR164.33(A)(1).