← All vessels
AGIA DOXA
Freight Ship · General Dry Cargo Ship class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named AGIA DOXA
AGIA DOXA is a 1977 freight ship. The Coast Guard has recorded 17 inspections since 1984, most recently in September 2021, along with 20 deficiencies and 1 operational control.
Records from 1984 to 2021. Most recent: inspection, 10 September 2021.
- Built
- 1977
- Last inspected
- 10 September 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 20 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7700922 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226245
Flag
SOUTH KOREA
—
Maury page id
psix-226245
Inspections, by type
…with no type recorded17
Years with a record
13 calendar years (1984–2021)
The 17 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it14053 - Regulatory (Subpart C or D), Gross Ton
9223 - Regulatory (Subpart C or D), Net Ton
23803 - Dead Weight, Ton
9223 - Regulatory (Subpart C or D), Net Ton
23803 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 17
10 September 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7309864
25 November 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 397843
26 July 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 393523
19 February 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 376053
26 September 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 38723
15 June 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 505292
27 February 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 44055
5 October 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 353620
22 May 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 343815
5 March 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 335614
27 July 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 459128
22 December 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 327483
21 October 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 319126
11 July 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 493872
29 January 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 306621
3 February 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 300001
17 August 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 297707
Deficiency record · 20
Engineering
Issued 26 July 1996
Resolved
Make permanent repairs to 1) soft patched and leaking S/W inlet pipe (2 areas) to the #2 generator L/O cooler, and 2) soft patched #2 generator_x001C_ air cooler S/W outlet pipe above the valve._x001C_ Solas 60, I/11
Accommodation/Occupational Safety
Issued 26 July 1996
Resolved
Make permanent repairs to 1) twine patched sanitary drain line above M/E cooling S/W pump discharge valve (discharge corroding pipe below), 2) two twine patched sections of the sanitary service line near connection to maindischarge line, below deck plate of No. group starter panel.
Accommodation/Occupational Safety
Issued 26 July 1996
Resolved
Make permanent repairs to two leaks in stbd side sewage tank inlet pipe (one near tank connection, one at T-connection over the D/O service tank. Solas 60, I/11
Engineering
Issued 26 July 1996
Resolved
Provide permanent containment for the M/E cylinder and M/E system oil connections, port and stbd side, aft; and the bilge waste oil discharge manifold, port side aft, prior to the next U.S. port after sailing foreign. 33 CFR 155.320
Fire Fighting
Issued 26 July 1996
Resolved
Repair the locking device for the fire door into the steering gear space (the handle/lock was removed and the door will not remain closed.)_x001C_ _x001C_ Solas 60 II/38
Fire Fighting
Issued 26 July 1996
Resolved
Remove all hold back devices for fire doors into the engine room._x001C_ _x001C_ Solas 60, I/11
Fire Fighting
Issued 26 July 1996
Resolved
Make permanent repairs to the wasted section of firemain, stbd side at the #3 cargo hold, aft (2 areas of seepage and wasted metal noted.)_x001C_ Solas 60, I/11
Fire Fighting
Issued 26 July 1996
Resolved
Repair the fire hydrant located at the stbd bow fire station. The valve isstuck in the open position._x001C_ Solas 60, I/11
Lifesaving
Issued 26 July 1996
Resolved
Make permanent repairs to the inoperative port bridge wing life buoy self igniting light, prior to departure from port._x001C_ Solas 60, III/21
Accommodation/Occupational Safety
Issued 26 July 1996
Resolved
Maintain temporary repairs to multiple leaking areas on sideshell of port side sewage tank, and make permanent repairs prior to the next U.S. port after sailing foreign._x001C_ Solas 60 I/11
Engineering
Issued 26 July 1996
Resolved
Make permanent repairs to 1) soft patched S/W cooling outlet pipe above M/ES/W cooling discharge valve, 2) soft patched S/W inlet line to aux condensor, 3) leak at elbow of S/W inlet line to #1 generator L/O cooler._x001C_ Solas 60 I/11
Lifesaving
Issued 26 July 1996
Resolved
Properly install the smoke signal for the stbd bridge wing life buoy, priorto departure from port._x001C_ Solas 60, III/21
Accommodation/Occupational Safety
Issued 26 July 1996
Resolved
Make permanent repairs to 1) soft patched F/W tank outlet pipe overhead at T-connection to main discharge line, between #1 and #2 generator,aft 2) rubber patched S/W overboard general service pipe, overhead near S/W pump control switches, prior to the next U.S. port after sailing foreign.
Lifesaving
Issued 26 July 1996
Resolved
Correct the leak in the air supply system for the port side lifeboat davit system, prior to port departure. (Holes in a connecting supply line allows loss of pressure/air to the system and reduces system efficiency.)_x001C_ Solas 60 III/36
Lifesaving
Issued 26 July 1996
Resolved
Obtain class approval for temporary repairs made to the two approximately 12 inch fractures on the stbd lifeboat at the chafe block, and make additional repairs as required._x001C_ Solas 60, III/4
Lifesaving
Issued 26 July 1996
Resolved
Properly install the tricing pendant for the starboard lifeboat, prior to departure from port. The current installation is backwards._x001C_ Solas 60 III/4
Engineering
Issued 26 July 1996
Resolved
Correct the leak at the port side bunker line shutoff valve and clean the oil from the surrounding deck, prior to departure from port._x001C_ 33 CFR 151.10
Accommodation/Occupational Safety
Issued 19 February 1995
Resolved
Service main deck water tight doors on fwd superstructure entrance both port and starboard, prior to departure from Portland, OR, per SOLAS Chap II, Reg 12(1).
Engineering
Issued 19 February 1995
Resolved
Install guard on emergency fire pump fly wheel, prior to departure from Portland, OR, per SOLAS Chap II-1, Reg 26(1).
Fire Fighting
Issued 19 February 1995
Resolved
Make permanent repairs to leaks in fire main, main deck, by #1 & #2 cargo holds stbd side, prior to departure from Portland, OR, per SOLAS Chap II-2,Reg 4.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.