MAURY USCG vessel records Sign in
← All vessels

ANARITA

ANARITA is a 1978 freight ship. The Coast Guard has recorded 13 inspections since 1988, most recently in July 2003, along with 15 deficiencies and 3 operational controls.

Records from 1988 to 2003. Most recent: operational control imposed, 4 August 2003.

Built
1978
Last inspected
29 July 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7702516 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226291
Flag
LIBERIA
—
Maury page id
psix-226291

Inspections, by type

…with no type recorded10
Years with a record 6 calendar years (1988–2003)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it32147 - Displacement, Metric Ton
26016 - Dead Weight, Metric Ton
9226 - Regulatory (Subpart C or D), Net Ton
15392 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

29 July 2003 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1860214
10 October 2002 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1688373
5 September 2002 Ballast Water Examination · Annual Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1671498
3 September 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1671370
9 August 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1674278
24 September 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 294081
18 September 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 293760
10 November 1998 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 422428
30 April 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 727139
27 February 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 71241
18 February 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 413075
21 October 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 361651
1 February 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 524548

Deficiency record · 15

Engineering
Issued 10 October 2002 Resolved
Loss of propulsion- 33 CFR 160.111
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2002
Resolved 11 October 2002
Resolution: ABS report states sea chest cooler filter was renewed. Also, coolers were cleaned and closed up in good order. Main engines were tested ahead and astern without incident.
Communications › Radio Communications
Issued 5 September 2002 Resolved
Emergency communication batteries for the GMDSS are cracked and defected. Replace/renew as required. LEGACY COMPONENT DESC: Emergency Source of Power
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 September 2002
Resolved 6 September 2002
Resolution: Received class report stating the batteries were replaced with new ones.
Engineering › Sea-water System (primary cooling)
Issued 5 September 2002 Resolved
Remove temporary hose from the sea cooling piping for the main engine starting compressor. LEGACY COMPONENT DESC: Piping
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 September 2002
Resolved 6 September 2002
Resolution: Received class report satisfying requirement.
Engineering › Freshwater System (jacketwater cooling)
Issued 5 September 2002 Resolved
Number one generator, cylinder number six has an excessive jacket water leak.
Action required: 705 - Other - as specified
Due 12 September 2002
Resolved 6 September 2002
Resolution: Received class report satisfying requirement.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 5 September 2002 Resolved
Number one generator, lube oil supply to cylinder number four fitting is loose and leaking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2002
Resolved 6 September 2002
Resolution: Received class report satisfying requirement.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 5 September 2002 Resolved
Number three generator, lube oil supply to cylinder number four fitting is loose and leaking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2002
Resolved 6 September 2002
Resolution: Received class report satisfying requirement.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 5 September 2002 Resolved
Number three generator, lube oil supply to cylinder number six is loose and leaking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2002
Resolved 6 September 2002
Resolution: Received class report satisfying requirement.
Lifesaving
Issued 18 September 2001 Resolved
SERVICE ALL LIFERAFTS AND REPLACE ONBOARD.
Condition: Unknown
Due 20 September 2001
Resolved 19 September 2001
Fire Fighting
Issued 18 September 2001 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS AND PLACE ONBOARD.
Condition: Unknown
Due 20 September 2001
Resolved 19 September 2001
Electrical
Issued 18 September 2001 Resolved
INSTALL ELECTRICAL MATTING AROUND ALL ELECTRICAL DISTRIBUTION PANELS.
Condition: Unknown
Due 18 November 2001
Resolved 25 September 2001
Accommodation/Occupational Safety
Issued 18 February 1998 Resolved
The weather tight doors need to close properly.
Condition: Unknown
Due 12 November 1998
Resolved 12 November 1998
Lifesaving
Issued 18 February 1998 Resolved
The starboard life boat can not raise properly with air.
Condition: Unknown
Due 25 September 2001
Resolved 25 September 2001
Fire Fighting
Issued 18 February 1998 Resolved
International shore connection missing gasket.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Documentation
Issued 18 February 1998 Resolved
The fire plan was missing and off the ship to be copied._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Navigation
Issued 21 October 1993 Resolved
VSL KAPITAN A. POLKOVSKIY HAD A INOPERATIVE GYRO COMPASS THAT WAS NOT REPORTED TO THE COTP._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 November 1998
Resolved 12 November 1998

Ownership record