← All vessels
OCEAN LADY I
Freight Ship · Ro-Ro Cargo Ship class · Built 1970s · USCG Northeast District (CGD-NE) · Other hulls named OCEAN LADY I
OCEAN LADY I is a 1973 freight ship. The Coast Guard has recorded 26 inspections since 1985, most recently in February 2009, along with 14 deficiencies and 5 operational controls.
Records from 1985 to 2009. Most recent: inspection, 20 February 2009.
- Built
- 1973
- Last inspected
- 20 February 2009
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 14 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7325215 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EKE7
226314
Flag
PANAMA
—
Maury page id
psix-226314
Inspections, by type
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it8337 - Regulatory (Subpart C or D), Net Ton
10414 - Dead Weight, Ton
25615 - Regulatory (Subpart C or D), Gross Ton
10414 - Dead Weight, Ton
25615 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
20 February 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3420866
23 January 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3398755
22 January 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3398087
16 January 2009
ISPS II Exam · Loadline Exam · MARPOL Annex I Examination · ILO-147 Exam · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3395133
10 August 2008
PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination · ISPS III Exam · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3292977
4 August 2008
ISM Exam · ISPS III Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3288738
27 March 2008
Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3169843
26 September 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3064884
28 June 2007
ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2970913
26 May 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2659831
26 May 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2659998
25 May 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2657433
24 May 2006
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2657948
13 December 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2551352
9 December 2005
MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2545097
27 October 2004
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2229669
12 June 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 417197
21 September 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 409192
17 September 1997
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 408213
27 April 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 402986
17 December 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 472102
3 November 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 319393
2 June 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 316456
3 June 1986
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 473907
22 January 1986
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 306588
3 May 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 301659
Deficiency record · 14
Operations/Management › Pollution › Control of Discharge of Oil
Issued 22 January 2009
Resolved
Class shall attest to the materiel condition, proper arrangement, and alignment of the fuel oil piping system and the legitimacy of the written fuel oil transfer procedures and the level of knowledge and training of the persons in charge of such procedures. MARPOL 73/78 Annex I/11
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 21 January 2009
Resolved
Due to objective evidence discovered during an expanded exam of the ship's maintenance procedures in accordance with the safety management system in the ship's engine room, steering gear compartment, and emergency fire pump, an external audit is recommended. SOLAS 74 Chapter 9 Regulation 3
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 21 January 2009
Resolved
Rudder angle indicator in steering gear compartment does not accurately reflect rudder angle. SOLAS 60 Chapter II Regulation 29 (a)(i)
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 21 January 2009
Resolved
Ship's emergency fire pump is inoperable. Vessel is required to have an operable fixed emergency fire pump. In the event of a fire, an inoperable emergency fire pump may result in a hazardous condition, endangering the vessel and crew. SOLAS 60 Chapter II Regulation 65 (b)(ii)
Lifesaving › Lifeboat › Propulsion Engine
Issued 21 January 2009
Resolved
Crew was unable to start the port motor lifeboat engine. Vessel is required to be fitted with a compression ignition engine and be capable of being readily started in all conditions. In the event of an abandon ship, an inoperable motor lifeboat engine may result in a hazardous condition that endangers the crew. SOLAS 60 Chapter III Regulation 9 (a)(i)
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 21 January 2009
Resolved
Engine room and steering gear compartment EEBD's oxygen level gauges indicate an inadequate supply. SOLAS 74 Consolidated Edition 2004 Regulation 4.3.1
Fire Fighting › Firemans Outfit › Boots
Issued 4 August 2008
Resolved
FIRE-FIGHTERS OUTFIT PROTECTIVE BOOTS OF INSUFFICIANT SIZE
Operations/Management › Drills/Instruction › Fire
Issued 4 August 2008
Resolved
UNABLE TO PERFORM PROPER FIRE FIGHTING DRILL, CREW MUST PERFORM FOR THE COAST GUARD A PROPER FIRE FIGHTING DRILL PRIOR TO DEPARTURE.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 9 December 2005
Resolved
Deck Hydraulic machinery gauges net maintained: Discharge pressure water gauge broken on forward Windlass Hydraulic Pump.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 December 2005
Resolved
Deck surface unsafe/slippery: Galley Fish Freezer (condensation) has thick layer of ice on deck. No provisions for ensuring crew safety on surface provided. Rectify deficiency to the satisfaction of Attending Classification Society.
Operations/Management › Ballast Water Managment › Training
Issued 9 December 2005
Resolved
Ballast Water Management Plan does not address procedures for crew training and familiarization. Rectify to the satisfaction of the attending Class Surveyor
Engineering
Issued 27 April 1997
Resolved
MAKE PERMANENT REPAIRS TO RUBBER HOSE LEADING FROM STERN TUBE HEAD TANK TO STERN TUBE PRIOR TO RETURNING TO NEXT US PORT AFTER A FOREIGN VOYAGE.
Documentation
Issued 2 June 1987
Resolved
THE OPERATOR OF THE VESSEL DID NOT PROVIDE OIL TRANSFER PROCEDURES THAT MEET THE REQUIREMENTS OF 33 CFR,PARTS 155AND 156, AS REQUIRED BY 33 CFR 155.720 NO OIL TRANSFER PROCEDURES ON BOARD.
Navigation
Issued 2 June 1987
Resolved
A VIOLATION OF 33CFR164.30 IN THAT VSL DID NOT HAVE O/B USCG LIGHT LIST VOL. 1 AND 2 OR THEIR FOREIGN EQUIVALENT, WHICH WERE REQUIRED FOR THE VSL'S ROUTE FROM THE C&D CANAL TO BALTIMORE HARBOR.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.