← All vessels
TOREPO
TOREPO is a 1974 tank ship. The Coast Guard has recorded 10 inspections since 1985, most recently in September 2001, along with 19 deficiencies and 1 operational control.
Records from 1985 to 2001. Most recent: inspection, 10 September 2001.
- Built
- 1974
- Last inspected
- 10 September 2001
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 19 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7326128 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HXQ3
226325
Flag
UNITED KINGDOM
—
Maury page id
psix-226325
Inspections, by type
The 10 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it9658 - Regulatory (Subpart C or D), Net Ton
25196 - Dead Weight, Ton
14943 - Regulatory (Subpart C or D), Gross Ton
25196 - Dead Weight, Ton
14943 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 10
10 September 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 293682
9 September 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 293038
29 March 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 288743
22 July 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 451180
24 September 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 318687
24 September 1987
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1010357
18 December 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 511422
23 March 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 301006
11 February 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 976420
9 February 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 300230
Deficiency record · 19
Engineering
Issued 29 March 2001
Resolved
OILY WATER SEPARATOR S/W CLEANING PIPE HAS SOFT PATCH. REPAIR TO THE SATISFACTION OF CLASS NO LATER THAN 12APR2001. RECEIVED CLASS REPORT INDICATING PIPE WAS PARTIALLY RENEWED AS NECESSARY. DEFICIENCY CLEARED.
Navigation
Issued 29 March 2001
Resolved
REMOVE HYDRAULIC OIL LEAKAGE FROM STEERING COMPARTMENT NO LATER THAN 12APR2001. RECEIVED CLASS REPORT INDICATING HYDRAULIC LEAKS WERE ELIMINATEDAND THE EXCESSIVE OIL MOPPED UP. STEERING GEAR WAS TESTED SAT WITH BOTH PUMPS AND IN EMERGENCY MODE. DEFICIENCY CLEARED.
Engineering
Issued 29 March 2001
Resolved
L/O COOLER S/W INLET PIPE MAIN VALVE HOLED AND LEAKING. REPAIR TO THE SATISFACTION OF CLASS NO LATER THAN 12APR2001. RECEIVED CLASS REPORT INDICATING PIPE WAS REPAIRED. DEFICIENCY CLEARED.
Engineering
Issued 29 March 2001
Resolved
F/W PIPING FOR F/O PURIFIER HOLED AND LEAKING. REPAIR TO THE SATISFACTION OF CLASS NO LATER THAN 12APR2001. RECEIVED CLASS REPORT INDICATING PIPING WAS PARTIALLY RENEWED. DEFICIENCY CLEARED.
Engineering
Issued 29 March 2001
Resolved
L/O PURIFIER PIPE FROM L/O TRANSFER PUMP HOLED AND LEAKING. REPAIR TO THE SATISFACTION OF CLASS NO LATER THAN 12APR2001. RECEIVED CLASS REPORT INDICATING PIPE WAS PARTIALLY RENEWED. DEFICIENCY CLEARED.
Engineering
Issued 29 March 2001
Resolved
DIESEL GENERATOR JACKET WATER OUTLET PIPE HAS SOFT PATCH. REPAIR TO THE SATISFACTION OF CLASS NO LATER THAN 12APR2001. RECEIVED CLASS REPORT INDICATING THE PIPE WAS PARTIALLY RENEWED. DEFICIENCY CLEARED.
Engineering
Issued 29 March 2001
Resolved
FUEL INJECTORS #1,2,3,5, AND 6 ON DIESEL GENERATOR LEAKS FUEL AND INCREASESAS GENERATOR TAKES ON SHIP'S FULL ELECTRICAL LOAD. REPAIR TO THE SATISFACTION OF CLASS NO LATER THAN 12APR2001. RECEIVED CLASS REPORT INDICATING GENERATOR TESTED UNDER FULL LOAD AND LEAKS HAVE BEEN ELIMINATED.
Engineering
Issued 29 March 2001
Resolved
STBD SIDE F/O TANK STEAM HEATING LINE HOLED AND LEAKING. REPAIR TO THE SATISFACTION OF CLASS NO LATER THAN 12APR2001. RECEIVED CLASS REPORT INDICATING STEAM LINE WAS PARTIALLY RENEWED. DEFICIENCY CLEARED.
Deck/Cargo
Issued 29 March 2001
Resolved
PROVE PROPER OPERATION OF OVERFILL AND HIGH LEVEL ALARMS TO THE SATISFACTION OF AN ATTENDING COAST GUARD INSPECTOR NO LATER THAN 12APR2001.VESSEL PROHIBITED FROM LOADING CARGO IN U.S. WATERS UNTIL ITEM CLEARED. RECEIVED CLASS REPORT INDICATING ALARMS TESTED SAT AT 96% AND 98% LEVELS.
Deck/Cargo
Issued 29 March 2001
Resolved
CARGO PUMP NO. 3 IS DISCONNECTED. CLASS TO APPROVE NEW ARRANGEMENT NO LATER THAN 12APR2001. RECEIVED CLASS RPT OFFICIALLY CONSIDERING THE PUMP OUT OF SERVICE. DEFICIENCY CLEARED.
Accommodation/Occupational Safety
Issued 29 March 2001
Resolved
SEWAGE PIPING OVERBOARD PIPE HOLED AND LEAKING. REPAIR NO LATER THAN 12APR2001. RECEIVED CLASS REPORT INDICATING PIPE WAS PARTIALLY RENEWED AS NECESSARY. DEFICIENCY CLEARED.
Unknown
Issued 24 September 1987
Resolved
ONE ACETYLENE AND TWO OXYGEN COMPRESSED GAS CYLINDERS UTILIZED FOR WELDING WERE BEYOND THEIR HYDROSTATIC TEST DATE AS REQUIRED BY 46 CFR 147.04-1.
Documentation
Issued 24 September 1987
Resolved
VESSEL DID NOT HAVE CURRENT OR UPDATED EDITIONS OF THE APPLICABLE REGULATIONS ON BOARD, 46 CFR 30-40
Navigation
Issued 9 February 1985
Resolved
THE VESSEL DID NOT HAVE ON BOARD AND MAINTAINED FOR READY REFERENCE A CURRENT COPY OF THE INLAND NAVIGATION RULES (IE: 1965 EDITION OF INLAND NAVIGATION RULES WITH CORRECTIONS THROUGH 1972 ON BOARD VESSEL) AS REQUIRED BY 33CFR88.05.
Documentation
Issued 9 February 1985
Resolved
A PERSON ON BOARD THE VESSEL WAS TRANSFERRING OIL FROM THE VESSEL WITHOUT EACH PERSON IN CHARGE FILLING OUT AND SIGNING THE DECLARATION OF INSPECTIONFORM AS REQUIRED BY 33CFR156.150(A).
Documentation
Issued 9 February 1985
Resolved
THE DECLARATION OF INSPECTION ON BOARD THE VESSEL DID NOT CONTAIN A SPACE FOR THE DATE, TIME OF SIGNING, SIGNATURE AND TITLE OF EACH PERSON IN CHARGEDURING OIL TRANSFER OPS ON THE TRANSFERRING VESSEL AND ON THE RECEIVING FACILITY AS REQUIRED BY 33CFR156.150(C)(5).
Fire Fighting
Issued 9 February 1985
Resolved
FIRE MAIN ON MAIN DECK WAS WASTED IN MULTI-AREAS
Engineering
Issued 9 February 1985
Resolved
CLEAN BOILER FRONTS AND REMOVE ANY OILY DEBRIS FROM ENGINEERING SPACES.
Construction/Loadline
Issued 9 February 1985
Resolved
VESSEL HAD HOLE IN HULL IN #1STBD CARGO TANK
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.