MAURY USCG vessel records Sign in
← All vessels

GLORY MOON

GLORY MOON is a 1973 freight ship. The Coast Guard has recorded 56 inspections since 1984, most recently in January 2006, along with 74 deficiencies and 5 operational controls, 1 with no removal date recorded.

Records from 1984 to 2006. Most recent: inspection, 24 January 2006.

Built
1973
Last inspected
24 January 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7328786 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226371
Flag
PANAMA
—
Maury page id
psix-226371

Inspections, by type

…with no type recorded32
Years with a record 14 calendar years (1984–2006)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it11843 - Simplified, Net Ton
7613 - Convention (Subpart B), Net Ton
25358 - Dead Weight, Ton
32808 - Displacement, Ton
14804 - Simplified, Gross Ton
16534 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BIGGIN Commercial Fishing Vessel · MISLE 346800 · 10 April 2001 · activity 169249

Inspection history · 56

24 January 2006 NPV Safety Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2572357
22 August 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2471178
5 August 2005 PII Safety Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2452026
15 July 2005 ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2427455
21 June 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2397473
26 May 2005 NPV Safety Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2369648
25 May 2005 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2367715
25 May 2005 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2368009
26 April 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2343068
9 March 2005 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2306613
8 March 2005 Ballast Water Examination · PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2305813
2 November 2004 Type not recorded
No type recorded · GROUP HAMPTON ROADS · USCG East District (CGD-E) · Activity 2234019
7 September 2004 NPV Safety Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2188859
11 August 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2162877
1 July 2004 ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2118155
26 June 2004 ISPS II Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2110709
3 June 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2087333
13 May 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2089245
2 April 2004 Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2036095
4 November 2003 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1941811
15 October 2003 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1929061
14 October 2003 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1927721
25 September 2003 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1912785
12 August 2003 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1875324
30 May 2003 Periodic Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1805680
5 November 2002 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1701287
29 October 2002 Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1697605
12 September 2002 Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1674497
26 June 2002 Administrative Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1642572
3 June 2002 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1625955
13 May 2002 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1616025
19 February 2002 Re-Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1487261
21 November 2001 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 295631
6 October 2001 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 294478
5 October 2001 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 294476
13 August 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 292603
29 June 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 291415
7 May 2001 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 289729
13 April 2001 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 289134
10 April 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 169249
22 September 2000 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 282140
16 March 2000 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 275887
20 September 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 274470
20 September 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 432996
5 April 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 427502
31 January 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 75415
12 August 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 419108
26 November 1995 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 385246
25 November 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 535259
2 June 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 316470
9 December 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 313196
21 July 1986 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 468988
8 November 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 304769
30 September 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 304438
24 June 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 481257
20 December 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 299435

Deficiency record · 74

Engineering › Lubricating Oil Service System › Cooler
Issued 15 July 2005 Resolved
Lube oil cooler line in the engine room has a cement patch in bilge frame 35. Make repairs to the satisfaction of the Administration. Condition of Class issued till 31AUG05.
Action required: 705 - Other - as specified
Due 31 August 2005
Resolved 22 August 2005
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS MADE, DEFICIENCY CORRECTED.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 July 2005 Resolved
Seawater cooling line for auxiliary generators has a rubber patch that is leaking, lower level engine room in overhead frame 30. Make repairs to the satisfaction of the Administration.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2005
Resolved 17 July 2005
Resolution: Received Class report.
Engineering › Fuel Oil Service System › Tank
Issued 15 July 2005 Resolved
Heavy fuel oil service tank has a crack in the upper corner that has temporary repair that is still leaking, frame 35, upper deck in engine room. Make repairs to the satisfaction of the Administration.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2005
Resolved 17 July 2005
Resolution: Received Class report.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 15 July 2005 Resolved
Bulkhead wasted at the bottom, between the engine room and crew accommodation passageway, upper deck port side between frames 30-35. Make repairs to the satisfaction of the Administration. Class issued condition till 31AUG05.
Action required: 705 - Other - as specified
Due 31 August 2005
Resolved 22 August 2005
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS MADE, DEFICIENCY CORRECTED.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 15 July 2005 Resolved
Items #1 - #4 have not been reported through the vessel's safe management, non-conformity reporting system. This is a failure of the Safe Management System that is implemented. Vessel is recommended to have an external audit completed and the report to be provide to the USCG prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2005
Resolved 17 July 2005
Resolution: ABS conducted audit.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 15 July 2005 Resolved
Bulkhead found wasted in the aft rope stores. Make repairs to the satisfaction of the Administration.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2005
Resolved 17 July 2005
Resolution: Received Class report.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 15 July 2005 Resolved
Crew cabins as identified on the Fire Plan are being used as storerooms, upper deck port side between frames #3 and #38. These spaces are to be approved as storerooms to the satisfaction of the Administration.
Action required: 705 - Other - as specified
Due 15 August 2005
Resolved 22 August 2005
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS MADE, DEFICIENCY CORRECTED.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 15 July 2005 Resolved
Several of the Panamanian Endorsement for the crews national licenses had no signatures, crew signed endorsements while onboard.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 15 July 2005
Resolution: Crew signed endorsements while onboard.
Accommodation/Occupational Safety › Potable Water System › General
Issued 15 July 2005 Resolved
Vessel has no hot water for crew to wash dishes, clothes or to take a bath or shower, provide hot water.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 17 July 2005
Resolution: Received Class report.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 8 March 2005 Resolved
Vessel failed to provide a Ballast Water Management plan (Vessel issued an NOV in the amount of $1,000 under 33 CFR 151.1510).
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 26 April 2005
Resolution: COPY OF PLAN RECIEVED
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 8 March 2005 Resolved
Rudder Angle Indicator not reading the same as the bridge. The angle is off between 5-7 deg when turned to STBD. (Must be cleared by IACS approved class society)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2005
Resolution: Received report from Llyod''s Register surveyor stating that the linkage between the rudder stock and transmitter has been straightened and the transmitting arrangement maintained. The RAI was tested and readings were found in order.
Lifesaving › Lifeboat › Propulsion Engine
Issued 8 March 2005 Resolved
Vessel's STBD Lifeboat engine was incapable of starting or operating within a timely manner. (Must be cleared by IACS approved class society)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2005
Resolution: Received report from Lloyd''s Register surveyor stating that the STBD lifeboat engine has been maintained and was tested satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 July 2004 Resolved
Wasted/broken rails by deck machinery space. (Forward/stbd. side)
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 August 2004
Resolved 11 August 2004
Resolution: RECIEVED REPORT FROM CLASS ATTESTING TO THE REPAIR OF THE RAILS BY THE DECK MACHINERY SPACE.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 July 2004 Resolved
Missing hand rails in engine room around oil purifier.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 August 2004
Resolved 11 August 2004
Resolution: RECIEVED REPORT FROM CLASS ATTESTING TO THE REPAIR OF THE HAND RAILS AROUND THE OIL PURIFER.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 July 2004 Resolved
Rusted/Wasted gas storage containment in poop deck area.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 August 2004
Resolved 11 August 2004
Resolution: RECIEVED REPORT FROM CLASS ATTESTING TO THE REPAIR OF THE GAS STORAGE CONTAINMENT.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 3 June 2004 Resolved
Vessel has been screened through the Port State Control matrix and identified as a Priority 1. Vessel cannot enter port until CG inspectors complete a Port State Contol examination.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 July 2004
Resolution: Attended vsl at Ambrose Anchroage. Vsl successfully passed ISPS Verification Exam.
Fire Fighting › Emergency Fire Pumps
Issued 2 April 2004 Resolved
EMERGENCY FIRE PUMP WAS UNABLE TO TAKE SUCTION. SOLAS 60 CH. 2 REG. 66 LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2004
Resolved 3 April 2004
Resolution: CORRECTED TO THE SATISFACTION OF AMERICAN BUREAU OF SHIPPING CLASS SOCIETY, DINESH THAREJA LEAD AUDITOR.
Accommodation/Occupational Safety › Occupational Safety
Issued 2 April 2004 Resolved
BOTH ACCOMODATION LADDERS WERE FOUND TO BE INOPERABLE, PORT SIDE WENCH MOTOR INOP. STARBOARD SIDE FRACTURES IN MOUNTING WELDS. LEGACY COMPONENT DESC: ACCOMODATION LADDERS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 3 April 2004
Resolution: CORRECTED TO THE SATISFACTION OF CLASS SOCIETY AMERICAN BUREAU OF SHIPPING, DINESH THAREJA, LEAD AUDITOR.
Operations/Management › Mandatory Ship Reporting Systems
Issued 2 April 2004 Resolved
NO NON-CONFORMATY REPORTS SUBMITTED OR O/B INOP EQUIPMENT (ie) SANITATION PUMP, ELEC WENCH MOTOR OR PORT SIDE ACCOMODATION LADDER. EXTERNAL AUDIT FROM CLASS REQUESTED. LEGACY COMPONENT DESC: ISM
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 April 2004
Resolved 3 April 2004
Resolution: CORRECTED TO THE SATISFACTON OF CLASS SOCIETY AMERICAN BUREAU OF SHIPPING, DINESH THAREJA LEAD AUDITOR.
Construction/Loadline › Markings
Issued 2 April 2004 Resolved
VESSEL FOUND NOT TO BE IN COMPLIANCE WITH ILL 166 CLASS LOAD-LINE CERTIFICATE. VESSEL IMPROPERLY MARKED AND DECK LINE NOT IN CONTRASTING COLOR AND NOT PERMANENTLY MARKED LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2004
Resolved 3 April 2004
Resolution: CORRECTED TO THE SATISFACTION OF CLASS
Pollution Prevention/Response › Prevention Equipment
Issued 2 April 2004 Resolved
TEMPORARY PIPING FOR SEWAGE DRAIN WAS PUT THROUGH HOLE IN DECK, CAUSING SEWAGE GASES EVIDENT IN LIVING AREAS. LEGACY COMPONENT DESC: Sewage System Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2004
Resolved 3 April 2004
Resolution: CORRECTED TO THE SATISFACTION OF CLASS
Electrical › Electric Supply System (service)
Issued 2 April 2004 Resolved
DEAD END WIRES FOUND WITH BOAT HOISTING EQUIPMENT ON PORT & STARBOARD LIFEBOAT STATIONS. LEGACY COMPONENT DESC: DEAD END WIRES
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2004
Resolved 3 April 2004
Resolution: CORRECTED TO THE SATISFACTION OF CLASS
Electrical › Lighting (service)
Issued 2 April 2004 Resolved
VARIOUS DECK HOUSE LIGHT FIXTURES WIRING WAS FOUND EXPOSED (main deck, crew accomodations) LEGACY COMPONENT DESC: WIRING
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2004
Resolved 4 May 2004
Resolution: Recieved Class Report
Accommodation/Occupational Safety › Washroom/Toilet
Issued 2 April 2004 Resolved
CREW ACCOMODATION W/C FACILITIES WERE UNABLE TO FLUSH WITHOUT 5 GAL. BUCKETS. LEGACY COMPONENT DESC: Toilet
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2004
Resolved 4 May 2004
Resolution: Recieved Class Report, installed new pumnp
Engineering › Diesel Engine (propulsion-direct drive)
Issued 14 October 2003 Resolved
O-RING SEAL FOR 1&6 CYLINDERS FOUND LEAKING, SHIP FORCE REPLACE, CLASS TO PROVIDE REPORT BEFORE FIRST U.S. PORT AFTER GOING FORIGEN LEGACY COMPONENT DESC: Cylinder Head
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 20 October 2003
Resolved 3 November 2003
Resolution: Attested by Lloyds''s Register.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 September 2003 Resolved
Liferails on stbd focstle and ladders require repair and/or replacement. LEGACY COMPONENT DESC: Deck Rail
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 15 October 2003
Resolution: Liferails have been replaced.
Fire Fighting › Fire Hoses › Condition
Issued 25 September 2003 Resolved
Replace fire hose on bridge and focstle.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 25 September 2003
Resolution: Replaced on the spot.
Electrical › Lighting (service)
Issued 25 September 2003 Resolved
Replace missing lighting fixtures and guards throughout the ship. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 20 October 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 25 September 2003 Resolved
Properly secure CO2 cylinders in CO2 room. LEGACY COMPONENT DESC: Tanks
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 15 October 2003
Resolution: CO2 cylinders have been secured.
Fire Fighting › Combustible Materials
Issued 25 September 2003 Resolved
Remove paint from Bosn storeroom and properly stow paint in paint locker. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Action required: 15 - Rectify deficiencies by next port
Resolved 15 October 2003
Resolution: Combustibles have been removed from bos''n store room.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 25 September 2003 Resolved
Repair broken valve in second officer stateroom head. LEGACY COMPONENT DESC: Toilet
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 20 October 2003
Fire Fighting › Fire Hoses
Issued 25 September 2003 Resolved
Hydrotest all fire hoses and replace as necessary. LEGACY COMPONENT DESC: Condition
Action required: 15 - Rectify deficiencies by next port
Resolved 15 October 2003
Resolution: Provided proof of hydrotesting for all fire hoses.
Accommodation/Occupational Safety › Occupational Safety
Issued 30 May 2003 Resolved
Lifelines on main deck must be replaced or repaired. LEGACY COMPONENT DESC: Lifelines
Due 30 June 2003
Resolved 29 June 2003
Resolution: Lifelines were replaced with new ones.
Stability › Watertight Integrity
Issued 30 May 2003 Resolved
Seal around watertight door for emergency generator space needs repaired. LEGACY COMPONENT DESC: Watertight door
Due 30 June 2003
Resolved 29 June 2003
Resolution: Seal has been replaced.
Accommodation/Occupational Safety › Occupational Safety
Issued 30 May 2003 Resolved
Electrical mat missing in emergency generator space. LEGACY COMPONENT DESC: Electrical mat
Due 30 June 2003
Resolved 29 June 2003
Resolution: Electrical mat has been installed.
Accommodation/Occupational Safety › Occupational Safety
Issued 30 May 2003 Resolved
Electrical mat missing in forward switchboard compartment, forecastle. LEGACY COMPONENT DESC: Electrical mat
Due 30 June 2003
Resolved 29 June 2003
Resolution: Electrical mat has been installed.
Electrical › Electric Supply System (service)
Issued 30 May 2003 Resolved
Wasted conduit in forecastle general storage compartment, needs repaired/replaced. LEGACY COMPONENT DESC: Conduit
Due 30 June 2003
Resolved 29 June 2003
Resolution: Conduit has been repaired to the satisfaction of class.
Construction/Loadline › Structures
Issued 30 May 2003 Resolved
Provide class attestation that bulkhead in forward switchboard compartment meets structural fire protection requirements in way of electrical cables, penetrations. LEGACY COMPONENT DESC: Bulkhead
Due 30 June 2003
Resolved 29 June 2003
Resolution: Bulkhead, cable penetrations, and conduits are acceptable to class.
Lifesaving › Lifeboat
Issued 29 October 2002 Resolved
Port lifeboat has repair to stbd aft inboard side. Lifeboat is de-laminating at side of repair and also on port aft inboard side. Class to attest to proper repair of gel-coating on lifeboat and attest to structural strength of lifeboat hull. LEGACY COMPONENT DESC: Hull
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 October 2002
Resolved 29 October 2002
Resolution: Class report.
Lifesaving › Lifeboat
Issued 29 October 2002 Resolved
Stbd lifeboat has fracture at fastener for grab rail on stbd aft outboard side. Class to attest to proper repair and structural strength & integrity of stbd lifeboat hull. LEGACY COMPONENT DESC: Handholds/Handrails
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 October 2002
Resolved 29 October 2002
Resolution: Class report.
Fire Fighting › Fire Main
Issued 29 October 2002 Resolved
BA03- Fireman aft of lifeboat (stbd side) next to ladder has doubler. Class to attest to proper repair of fire main. LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 29 October 2002
Resolved 29 October 2002
Resolution: Class report.
Engineering
Issued 12 September 2002 Resolved
THE FOLLOWING PUMPS LEAK EXCESSIVLY: FRESH WATER PUMP, PORT SIDE; DECK MACHINERY COOLING PUMPS; BALLAST/FIRE PUMPS; GENERAL SERVICE PUMP; PUMPS IN WAY OF CASCADE TANK. MAKE PERMINENT REPAIRS TO SATISFACTION OF CLASS SOCIETY LEGACY COMPONENT DESC: LEAKING PUMPS
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 13 September 2002
Resolution: Cleared per class report dated 13Sep02, certificate #MMI 0250121.
Engineering › Steam System (auxiliary)
Issued 12 September 2002 Resolved
STEAM PIPE IN WAY OF CASCADE TANK IS WASTED AND LEAKING. PERMANENT REPAIRS TO SATISFACTION OF CLASS SOCIETY LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 13 September 2002
Resolution: Condition of class now imposed per class report dated 13Sep02, certificate # MMI 0250121.
Engineering › Freshwater System (jacketwater cooling)
Issued 12 September 2002 Resolved
MAIN ENGINE JACKET WATER FRESH WATER COOLER LEAKING IN WAY OF EFFLUENT PIPE. MAKE PERMANENT REPAIRS TO SATISFACTION OF CLASS SOCIETY LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 13 September 2002
Resolution: Condition of class now imposed per class report dated 13Sep02, certificate # MMI 0250121.
Engineering › Lubricating Oil Service System
Issued 12 September 2002 Resolved
MAIN ENGINE LUBE OIL COOLER AFT LEAKING AND WASTED. TEMP REPAIR ON PIPE LEAKING. MAKE PERMANENT REPAIRS TO SATISFACTION OF CLASS LEGACY COMPONENT DESC: Cooler
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 13 September 2002
Resolution: Piping iwo lube oil cooler now repaered, tested and found tight per class report dated 13Sep02, certificate #MMI 0250121.
Engineering › Feedwater/Condensate Water System
Issued 12 September 2002 Resolved
AUX CONDENSATE CONDENSOR EFFLUENT PIPE SEVERLY WASTED AND SPRAYING WATER. MAKE PERMANENT REPAIRS TO SATISFACTION OF CLASS LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 13 September 2002
Resolution: Condition of class now imposed per class report dated 13Sep02, certificate # MMI 0250121.
Deck/Cargo › Holds/Tanks
Issued 12 September 2002 Resolved
FOUND BROKEN HATCH COAMING BRACKET ON PORT SIDE #5 CARGO HOLD. MAKE PERMANENT REPAIRS TO SATISFACTION OF CLASS LEGACY COMPONENT DESC: Coaming
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 13 September 2002
Resolution: Condition of class now imposed per class report dated 13Sep02, certificate # MMI 0250121.
Construction/Loadline › Structures
Issued 12 September 2002 Resolved
SEA WATER COOLING PIPES FOR DECK MACHINERY WASTED AND FOUND TO HAVE TEMP REPAIRS IN WAY OF #5 CARGO HOLDSTBD SIDE MAIN DECK. MAKE PERMANENT REPAIRS TO SATISFACTION OF CLASS SOCIETY LEGACY COMPONENT DESC: DECK MACHINERY COOLING LINES
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 13 September 2002
Resolution: Condition of class now imposed per class report dated 13Sep02, certificate # MMI 0250121.
Lifesaving › Launching Appliances
Issued 12 September 2002 Resolved
REPAIR LIMIT SWITCH STBD LIFEBOAT DAVIT SYSTEM AND RE-MOUNT SO THAT SWITCH MAKES CONTACT W/ STRIKE PLATE. CLASS TO ATTEST TO PROPER REPAIR AND OPERATION OF LIMIT SWITCH PRIOR TO DEPARTURE OF BALTIMORE LEGACY COMPONENT DESC: LIMIT SWITCH
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2002
Resolved 13 September 2002
Resolution: Stbd lifeboat davit limit switch now replaced, tested, found satisfactory per class report dated 13Sep02, certificate # MMI 0250121.
Electrical › Electric Generation Source (emergency)
Issued 12 September 2002 Resolved
REPLACE ALL BATTERY WIRING TO EMERGENCY BATTERIES LOCATED AFT OF DECK HOUSE IN LOCKER. WIRES FRAYED AND WASTED LEGACY COMPONENT DESC: BATTERY/ BATTERY CABLES
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 13 September 2002
Resolution: New cables fitted to radio emergency batteries and one new battery fitted. All found satisfactory per class report dated 13Sep02, certificate # MMI 0250121.
Fire Fighting › Fire Main
Issued 12 September 2002 Resolved
REPAIR WASTED/HOLED FIRE MAIN PORT SIDE AS MARKED. FIRE MAIN TESTED W/NO DEFICIENCIES NOTED LEGACY COMPONENT DESC: PIPING
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 13 September 2002
Resolution: Fire main tested and found tight. Suitable memoranda now imposed for permanent repairs per class report dated 13Sep02, certificate # MMI 0250121.
Deck/Cargo › Mooring/Anchoring
Issued 12 September 2002 Resolved
STBD SIDE ANCHOR WINCH FRAME PLATING HOLED AND WASTED. REPAIR AS ORIGINAL. SOLAS 74A TEG I/II. LEGACY COMPONENT DESC: Frame plating
Due 12 October 2002
Resolved 13 September 2002
Resolution: Condition of class now imposed per class report dated 13Sep02, certificate # MMI 0250121
Lifesaving › Embarkation Appliances/Stations
Issued 12 September 2002 Resolved
REPAIR FORWARD LADDER ON BOTH PORT AND STBD LIFEBOAT DECK. LADDER RUNGS WASTED. ILO 147 LEGACY COMPONENT DESC: Ladders
Due 12 October 2002
Resolved 13 September 2002
Resolution: New ladders fitted and found satisfactory per class report dated 13Sep02, certificate # MMI 0250121.
Pollution Prevention/Response › Prevention Equipment
Issued 12 September 2002 Resolved
MSD WASTED AND LEAKING LIQUIDS AND FUMES. MSD MUST BE REPAIRED TO PREVENT THE ESCAPE OF VAPORS AND FLUIDS. ( 33 CFR 159.95). LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Due 12 October 2002
Resolved 29 October 2002
Resolution: Re-Inspected by [name withheld], and was repaired to the satisfaction of attending marine inspector.
Navigation › Collision/Grounding Avoidance
Issued 3 June 2002 Resolved
Provide speed input device for Arpa. Correct prior to departure from next U.S. port. LEGACY COMPONENT DESC: Automatic Radar Plotting Aid (ARPA)
Condition: Unknown
Due 4 June 2002
Resolved 5 June 2002
Resolution: Vessel has exemption from Class on behalf of Flag State to expire on 11Jul02.
Accommodation/Occupational Safety
Issued 5 October 2001 Resolved
CROP AND RENEW WASTED SECTIONS OF MARINE SANITATION DEVICE.
Condition: Unknown
Due 21 November 2001
Resolved 21 November 2001
Navigation
Issued 5 October 2001 Resolved
REPAIR/REPLACE LEAKING SEALS ON STEERING GEAR.
Condition: Unknown
Due 6 October 2001
Resolved 6 October 2001
Electrical
Issued 13 April 2001 Resolved
SECURE BATTERIES LOCATED IN BATTERY ROOM AFT OF BRIDGE.
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Electrical
Issued 13 April 2001 Resolved
REMOVE UNSAFE WIRING IN STEWARDS CABIN & INSPECT ACCOMADATIONS FOR MORE IMPROPER WIRING.
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Accommodation/Occupational Safety
Issued 13 April 2001 Resolved
PROVIDE CLASS STATEMENT THAT LAUNDRY ROOM MEETS FIRE INTEGRITY REGULATIONS.
Condition: Unknown
Due 13 April 2001
Resolved 23 April 2001
Electrical
Issued 13 April 2001 Resolved
PROVIDE COVERS FOR OPEN LIGHTS THROUGHOUT ACCOMADATION SPACES.
Condition: Unknown
Due 13 August 2001
Resolved 13 August 2001
Electrical
Issued 13 April 2001 Resolved
PROVIDE RUBBER ELECTRICAL SAFETY MATTING BEHIND MAIN BOARDS IN ENGINE ROOM.
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Fire Fighting
Issued 13 April 2001 Resolved
PROVIDE CLASS CERTIFICATION THAT MODIFICATIONS TO FIRE NOZZLES MEET SOLAS.
Condition: Unknown
Due 13 April 2001
Resolved 23 April 2001
Lifesaving
Issued 13 April 2001 Resolved
DERUST BOTH LIFEBOAT RELEASING GEAR CHAIN PLATES. HAVE CLASS/FLAG STATE INSPECT WASTAGE AND PROVIDE RECOMMENDATIONS.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Lifesaving
Issued 13 April 2001 Resolved
UPDATE SHIPBOARDD TRAINING MANUAL TO REFLECT EQUIPMENT ON BOARD TO INCLUDE BUT NOT LIMITED TO: LIFERAFTS, HYDROSTATIC RELEASES, LIFEJACKETS. IN THE LANGUAGE OF THE CREW UNDERSTANDS.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Construction/Loadline
Issued 13 April 2001 Resolved
SUBMIT BALLAST WATER REPORTING FORM AS REQUIRED.
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Navigation
Issued 13 April 2001 Resolved
PROVIDE AUTOMATIC SPEED THROUGH WATER INPUT DEVICE TO ARPA RADAR OR PROVIDEEXEMPTION FROM FLAG STATE WITH EXPLANATION.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Accommodation/Occupational Safety
Issued 13 April 2001 Resolved
REPAIR TOILET IN HOSPITAL SPACE.
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Documentation
Issued 8 November 1985 Resolved
A VIOLATION OF 33 CFR 155.450 IN THAT THE VSL DID NOT HAVE O/B A DISCHARGE OF OIL PROHIBITED PLACARD IN EITHER EACH MACHINERY SPACE OR AT THE BILGE AND BALLAST CONTROL STATION.
Condition: Unknown
Due 8 November 1985
Resolved 8 November 1985
Navigation
Issued 8 November 1985 Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT THE STEERING GEAR OPERATING AND CHANG-EOVER INSTRUCTIONS AND STERING GEAR BLOCK DIAGRAM REQ BY 33 CFR 164.35 (K) WERE NOT PERMANENTLY DISPLAYED ON THE BRIDGE AND STEERING GEAR COMPARTMENT.
Condition: Unknown
Due 8 November 1985
Resolved 8 November 1985
Navigation
Issued 20 December 1984 Resolved
A VIOLATION OF 33CFR164.30 IN THAT A SET OF U.S. CHARTS, OR THEIR EQUIVALENTS, OF THE AREA TRANSITED THAT WERE CURRENTLY CORRECTED, AS REQ. BY 33CFR164.33(A)(2)(II) WERE NOT O/B VSL. VSL HAD CH# 12221 DTD 8/82 LAST CORRECTED TO 1/84, AND CH# 12222 DTD 6/83 LAST CORRECTED TO 1/84.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Navigation
Issued 20 December 1984 Resolved
A VIOLATION OF 33CFR164.30 IN THAT A CURRENTLY CORRECTED COPY OF U.S. COASTPILOT VOL.3, OR ITS EQUIVALENT, AS REQ. BY 33 CFR 164.33(A)(2)(I) WAS NOT ON BOARD. THE VSL HAD ON BOARD U.S. COAST PILOT VOL.3 DTD 1983 WITH NO CORRECTIONS. LATEST CORRECTION FOR U.S. COAST PILOT VOL.3 IS 30/84.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Navigation
Issued 20 December 1984 Resolved
A VIOLATION OF 33CFR164.11(Q) IN THAT THE PRE-ARRIVAL TESTS REQ. BY 33 CFR 164.25 WERE NOT LOGGED.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984
Navigation
Issued 20 December 1984 Resolved
A VIOLATION OF 33CFR164.30 IN THAT THE CONTINUOUS RECORDER REQ. BY 33 CFR 164.35(I) WAS NOT MAINTAINED IN AN OPERABLE CONDITION WHILE THE VESSEL WAS UNDERWAY.
Condition: Unknown
Due 20 December 1984
Resolved 20 December 1984

Ownership record