Records from 1986 to 2000. Most recent: operational control imposed, 11 September 2000.
Inspection history · 16
11 September 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 282051
30 December 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 411282
22 December 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 411424
17 August 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 406879
26 January 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 364042
16 January 1994
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1405483
14 January 1994
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 363758
14 January 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 646423
11 January 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 363640
14 January 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 341296
14 January 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 341376
22 February 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 328617
15 January 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 313792
11 December 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 313230
29 April 1986
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 308290
28 April 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 308390
Construction/Loadline
Issued 11 September 2000
No resolution recorded
OILY WATER SEPARATOR ALARM NOT CAPABLE OF AUTOMATIC OPERATION.
Condition: Unknown
Due 12 September 2000 — due date passed with no resolution recorded
Lifesaving
Issued 11 September 2000
No resolution recorded
STBD LIFEBOAT HOLED.
Condition: Unknown
Due 12 September 2000 — due date passed with no resolution recorded
Lifesaving
Issued 11 September 2000
No resolution recorded
LIFEBOAT EQUIPMENT MISSING OR OUTDATED, AS SPECIFIED IN OUTSTANDING CONDITIONS OF CLASS.
Condition: Unknown
Due 12 September 2000 — due date passed with no resolution recorded
Lifesaving
Issued 11 September 2000
No resolution recorded
STBD LIFEBOAT RELEASE MECHANISM BROKEN IWO AFT JOINT.
Condition: Unknown
Due 12 September 2000 — due date passed with no resolution recorded
Lifesaving
Issued 11 September 2000
No resolution recorded
STBD LIFEBOAT EXHAUST HAS BROKEN PIPING, MISSING ENGINE COVER, DETERIORATEDFLOOR, AND EXPANDED BOUYANCY TANKS.
Condition: Unknown
Due 12 September 2000 — due date passed with no resolution recorded
Lifesaving
Issued 17 August 1997
Resolved
EPIRB not onboard, out for servicing. Solas 74 (ammended) Reg II/7
Condition: Unknown
Due 19 August 1997
Resolved 20 August 1997
Fire Fighting
Issued 17 August 1997
Resolved
Two holes found in fire main piping located (1) aft of cargo hold #1 and (2) stbd side of deckhouse on boat deck. Fire main maintained adequate pressure. SOLAS 60 Reg II/56(e)
Condition: Unknown
Due 2 January 1998
Resolved 2 January 1998
Lifesaving
Issued 17 August 1997
Resolved
Unable to rapidly recover stbd lifeboat from embarkation deck. _x001C_ SOLAS 60 Reg III/36(i)
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Fire Fighting
Issued 16 January 1994
Resolved
Renew and prove proper operation of firemain plug valve located port side of forward cargo hold prior to getting underway.
Condition: Unknown
Due 18 January 1994
Resolved 18 January 1994
Lifesaving
Issued 16 January 1994
Resolved
Repair and prove proper operation of two 01 deck lifering lights prior to departure from port.
Condition: Unknown
Due 16 January 1994
Resolved 16 January 1994
Navigation
Issued 16 January 1994
Resolved
Repair and prove proper operation of gyrocompass prior to departure from port..
Condition: Unknown
Due 16 January 1994
Resolved 18 January 1994
Documentation
Issued 11 January 1993
Resolved
DURING EXAMINATION NOTICED VESSEL'S OIL TRANSFER PROCEDURES DID NOT INCLUDEA LIST OF EACH PRODUCT TRANSFERRED BY THE VESSEL.
Condition: Unknown
Due 14 January 1994
Resolved 14 January 1994
Engineering
Issued 14 January 1991
Resolved
ALARM ON OILY WATER SEPARATOR WAS INOPERABLE AS REQUIRED BY _x001C_ 33 CFR 155.380(d)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 January 1994
Resolved 14 January 1994
Documentation
Issued 28 April 1986
Resolved
THE VESSEL'S OIL TRANSFER PROCEDURES WERE INCOMPLETE IN THAT THEY DID NOT CONTAIN INFORMATION REQUIRED BY 33CFR155.750(A)(2)(III),(5),(6),(7),(8) AND (9)
Condition: Unknown
Due 29 April 1986
Resolved 28 April 1986
Documentation
Issued 28 April 1986
Resolved
THE VESSEL DID NOT HAVE A WRITTEN RECORD OF THE DATE AND RESULTS OF THE TESTS REQUIRED BY 33CFR156.170
Condition: Unknown
Due 29 April 1986
Resolved 28 April 1986
Navigation
Issued 28 April 1986
Resolved
THE VESSEL'S U.S. CHARTS 12214, 12304, 12311, AND 12312 WERE NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 15 January 1987
Resolved 28 April 1986