MAURY USCG vessel records Sign in
← All vessels

SEABORN II

SEABORN II is a 1974 tank ship. The Coast Guard has recorded 13 inspections since 1985, most recently in September 1991, along with 6 deficiencies.

Records from 1985 to 1991. Most recent: inspection, 6 September 1991.

Built
1974
Last inspected
6 September 1991
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7332529 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226417
Flag
GREECE
—
Maury page id
psix-226417

Inspections, by type

…with no type recorded8
Years with a record 4 calendar years (1985–1991)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 35 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it13207 - Regulatory (Subpart C or D), Net Ton
31120 - Dead Weight, Ton
17798 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

6 September 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1254285
21 April 1991 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1233928
17 August 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 325132
17 August 1988 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039367
10 November 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 312648
10 November 1986 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016996
10 September 1986 Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 457739
19 July 1986 Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 988245
20 May 1986 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 537515
1 October 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 304614
1 October 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 304740
1 October 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1294189
18 September 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 479358

Deficiency record · 6

Deck/Cargo
Issued 21 April 1991 Resolved
ALL P/V VALVE FLAME SCREENS TO BE REPLACED WITH PROPER SCREEN PRIOR TO LOADING GRADE 'B',C' & 'D' CARGOES.
Condition: Unknown
Due 21 April 1991
Resolved 21 April 1991
Fire Fighting
Issued 21 April 1991 Resolved
CLEAN ALL WATER SPRAY NOZZLES IN PUMP ROOM SPACE PRIOR TO CARGO TRANSFER OPERATIONS.
Condition: Unknown
Due 21 April 1991
Resolved 21 April 1991
Navigation
Issued 21 April 1991 Resolved
MAKE OPERABLE THE FOLLOWING NAVIGATION EQUIPEMENT: (1) VHF-FM RADIO (DC POWERED), (2) VESSELS NEW ARPA RADAR SYSTEM
Condition: Unknown
Due 21 April 1991
Resolved 21 April 1991
Deck/Cargo
Issued 1 October 1985 Resolved
"T" HANDLES FOR VALVES AT MANIFOLD MISSING OR NOT ATTACHED - REQUIRED PERMANENT INSTALLATION.
Condition: Unknown
Due 1 October 1985
Resolved 1 October 1985
Accommodation/Occupational Safety
Issued 1 October 1985 Resolved
MSD SYSTEM HAS NO IDENTIFYING DATA OR CG APPROVAL INFORMATION AVAILABLE. SUBMIT REQUEST TO OBTAIN APPROVAL/ACCEPTANCE.
Condition: Unknown
Due 1 October 1985
Resolved 1 October 1985
Electrical
Issued 1 October 1985 Resolved
CONDUIT FROM CARGO CONTROL ROOM TO PUMP ROOM VALVES INDICATING VALVE POSITION HAVE BEEN DISCONNECTED AND REQUIRE REMOVAL OR POSITIVE SEALING AT BOTH ENDS TO PREVENT VAPOR ESCAPE IN HOUSE.
Condition: Unknown
Due 1 October 1985
Resolved 1 October 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.