MAURY USCG vessel records Sign in
← All vessels

DIMANTS

DIMANTS is a 1973 freight ship. The Coast Guard has recorded 11 inspections since 1994, most recently in June 1999, along with 113 deficiencies — 10 with no resolution recorded — and 1 operational control.

Records from 1994 to 1999. Most recent: inspection, 21 June 1999.

Built
1973
Last inspected
21 June 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7333274 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226424
Flag
RUSSIA
—
Maury page id
psix-226424

Inspections, by type

…with no type recorded11
…past their stated due date10
Years with a record 6 calendar years (1994–1999)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2955 - Regulatory (Subpart C or D), Net Ton
9494 - Dead Weight, Ton
9850 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AMERICAN FREEDOM Commercial Fishing Vessel · MISLE 249764 · 22 July 1995 · activity 347

Inspection history · 11

21 June 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 429854
14 May 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 415878
9 March 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 505015
6 February 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 400078
13 August 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 393827
6 June 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 691086
21 May 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 391314
22 July 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 347
23 April 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 460400
1 February 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 691080
25 January 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 363930

Deficiency record · 113

Electrical
Issued 21 June 1999 No resolution recorded
REPAIR/ RENEW AS ORIGINAL SOURCE OF SMOKE-LIKE LEAK FOUND IN WAY OF #3 GENERATOR SET. SOLAS 74 (AMENDED) I/11.
Condition: Unknown
Due 5 July 1999 — due date passed with no resolution recorded
Electrical
Issued 21 June 1999 Resolved
REPAIR/RENEW AS ORIGINAL COOLING WATER LEAK IN #4 GENERATOR SET. SOLAS 74(AMENDED) I/11.
Condition: Unknown
Due 21 June 1999
Resolved 8 July 1999
Construction/Loadline
Issued 21 June 1999 No resolution recorded
REPAIR/RENEW AS ORIGINAL/ PREVENT EXCESSIVE LEAKS OF OIL INTO BILGES (#3 GENERATOR SET SHOWS EXCESSIVE OIL LEAKS THROUGH DRAIN INTO BILGES.)_x001C_ MARPOL 73/78 ANNEX I/14.
Condition: Unknown
Due 5 July 1999 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 21 June 1999 Resolved
REPAIR/RENEW AS ORIGINAL LEAK AND SOFT PATCH FOR FRESH WATER SYSTEM FOR ACCOMMODATIONS. SOLAS 74 (AMENDED) I/11.
Condition: Unknown
Due 21 June 1999
Resolved 8 July 1999
Engineering
Issued 21 June 1999 No resolution recorded
REPAIR/RENEW AS ORIGINAL MIAN ENGINE COOLING LINE IN WAY OF SOFT PATCHES. SOLAS 74 (AMENDED) I/11.
Condition: Unknown
Due 5 July 1999 — due date passed with no resolution recorded
Documentation
Issued 21 June 1999 No resolution recorded
PROVIDE APPROVAL LETTER FROM FLAG STATE THAT CONFIRMS LATVIAN/ RUSSIAN OFFICERS LICENSES ARE RECOGNIZED BY PANAMA. STCW 95 II.
Condition: Unknown
Due 5 July 1999 — due date passed with no resolution recorded
Lifesaving
Issued 21 June 1999 Resolved
ENSURE LIFEBOAT WINCH FOR STARBOARD LIFEBOAT IS PROPERLY GREASED AT THE BRAKE TO ELIMINATE FRICTION WHEN BOAT IS LOWERED. SOLAS 74(AMENDED) I/11.
Condition: Unknown
Due 21 June 1999
Resolved 8 July 1999
Lifesaving
Issued 21 June 1999 No resolution recorded
HAVE CLASS SOCIETY ATTEST/APPROVE REPAIRS TO STARBOARD LIFEBOAT IN WAY OF SOFT PATCHES ON KEEL AFT AND ON QUARTER HULL PORTSIDE AFT. REPAIR/RENEW AS ORIGINAL DAMAGED SHIFTED DOORS INTO LIFEBOAT, REPLACE CRACKED WINDOW. PROVIDE SURVEY/REPAIR SUMMARY TO SOFT PATCHES ON HULL. SOLAS 60 III/5.
Condition: Unknown
Due 5 July 1999 — due date passed with no resolution recorded
Fire Fighting
Issued 21 June 1999 Resolved
ENSURE ALL FIRE DOORS ARE CAPABLE OF CLOSING AND LATCHING UNDER DOORS OWN WEIGHT. SOLAS 74 (AMENDED) I/11.
Condition: Unknown
Due 21 June 1999
Resolved 8 July 1999
Electrical
Issued 21 June 1999 Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR. SOLAS 60 II/26.
Condition: Unknown
Due 21 June 1999
Resolved 8 July 1999
Lifesaving
Issued 21 June 1999 Resolved
PROPERLY EXECUTE FIRE AND ABANDON SHIP DRILLS IN THE PRESENCE OF A USCG MARINE SAFETY INSPECTOR. SOLAS 74 (UNAMENDED) III/18.3.7 AND SOLAS 74(AMENDED) XI/4.
Condition: Unknown
Due 21 June 1999
Resolved 8 July 1999
Construction/Loadline
Issued 21 June 1999 Resolved
PUMPOUT OIL IN BILGES IN WAY OF GENERATOR SETS TO EITHER AN APPROVED SHORESIDE FACILITY OR INTO SLUDGE TANK IF CAPACITY ALLOWS. MARPOL 73/78 ANNEX I/17.
Condition: Unknown
Due 24 June 1999
Resolved 8 July 1999
Unknown
Issued 21 June 1999 No resolution recorded
REPAIR/RENEW AS ORIGINAL EVAPORATOR FRESH WATER LINE IN WAY OF SOFT PATCHES. SOLAS 74 (AMENDED) I/11.
Condition: Unknown
Due 5 July 1999 — due date passed with no resolution recorded
Unknown
Issued 21 June 1999 No resolution recorded
PROVIDE VALVE HANDLES FOR VARIOUS SYSTEMS THROUGHOUT ENGINE ROOM. SOLAS 74(AMENDED) I/11.
Condition: Unknown
Due 5 July 1999 — due date passed with no resolution recorded
Electrical
Issued 21 June 1999 No resolution recorded
REMOVE/PROPERLY SECURE ELECTRICAL WIRES FOUND IN STATEROOM #445. SOLAS 60 II/57(a).
Condition: Unknown
Due 5 July 1999 — due date passed with no resolution recorded
Electrical
Issued 21 June 1999 No resolution recorded
PROPERLY SECURE WIRES IN JUNCTION BOX LOCATED IN OVERHEAD NEAR FIRE PUMP INENGINE ROOM. SOLAS 60 II/27(a).
Condition: Unknown
Due 5 July 1999 — due date passed with no resolution recorded
Engineering
Issued 21 June 1999 No resolution recorded
PRESSURE WASH/CLEAN MACHINERY SPACE. ENSURE RESIDUES ARE PUMPED TO AN APPROVED SHORE SIDE FACILITY. PROVIDE RECEIPTS ATTESTING TO SUCH DISCHARGE TO THE COGNIZANT [name withheld] 74 (AMENDED) I/11.
Condition: Unknown
Due 22 June 1999 — due date passed with no resolution recorded
Engineering
Issued 21 June 1999 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR, 15 PPM ALARM AND AUTOMATIC STOPPING DEVICE. MARPOL 73/78 ANNEXI/16.
Condition: Unknown
Due 21 June 1999
Resolved 8 July 1999
Fire Fighting
Issued 21 June 1999 Resolved
REPAIR/RENEW AS ORIGINAL SOFT PATCH ON FIRE MAIN PORT SIDE FORWARD. SOLAS 60 II/56.
Condition: Unknown
Due 21 June 1999
Resolved 8 July 1999
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE VENTILATION CLOSURE LOCATED STBD SIDE OF #2 DECK_x001C_ HOUSE._x001C_ SOLAS 60 II/47(a) _x001C_
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE VENT CLOSURE TO PORT SIDE OF #1 DECK HOUSE._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Electrical
Issued 21 May 1996 Resolved
PROVE SATISFACTORY OPERATION OF THE EMERGENCY GENERATOR AND AUTOMATIC_x001C_ START-UP FUNCTION.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Engineering
Issued 21 May 1996 Resolved
PROVE SATISFACTORY OPERATION OF ALL REMOTE STOPPING DEVICES FOR FUEL/OIL_x001C_ TANKS LOCATED IN THE ENGINE ROOM._x001C_ SOLAS 60 II/69(c)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Lifesaving
Issued 21 May 1996 Resolved
PROVIDE SKATES FOR PORT AND STBD LIFEBOATS OR OTHER SUITABLE MEANS TO_x001C_ FACILITATE LAUNCHING THE LIFEBOATS AGAINST A LIST OF 15 DEGREES._x001C_ SOLAS 60 III/29(h)
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Engineering
Issued 21 May 1996 Resolved
PROVE SATISFACTORY OPERATION OF THE OILY WATER SEPARATOR TO THE _x001C_ SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR. _x001C_ 33 C.F.R. 155.360
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Electrical
Issued 21 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER COOLING SUPPLY PIPE TO DIESEL_x001C_ GENERATORS LOCATED ENGINE ROOM 2nd LEVEL STBD SIDE (8" PIPE) _x001C_ SOLAS 74 (AMENDED) I/11(a)
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Engineering
Issued 21 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED FRESH WATER SUPPLY PIPE FOR MACHINERY_x001C_ COOLING LOCATED ENGINE ROOM 2nd LEVEL STBD SIDE. _x001C_ SOLAS 74 (AMENDED) I/11(a)
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER PIPE FOR DISTILLING SYSTEM LOCATEDIN THE BOILER ROOM AFT STBD SIDE (ON DECK) _x001C_ SOLAS 74 (AMENDED) I/11(a)
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW AS ORIGINAL HOLED CLASS "A" BULKHEAD AFT IN MAIN GALLEY.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED BILGE SUCTION PIPING LOCATED AT THE BILGE_x001C_ MANIFOLD ENGINE ROOM LOWER LEVEL PORT SIDE. _x001C_ SOLAS 74 (AMENDED) I/11(a)
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Lifesaving
Issued 21 May 1996 Resolved
REMOVE EXCESS OIL AND OIL RESIDUE FROM THE IMMEDATE AREA SURROUNDING THE_x001C_ MAIN GENERATORS, PURIFIERS, THE MAIN ENGINE AND ALL BILGE AREAS. ENSURE_x001C_ ALL CONTAINMENTS WITHIN THE ENGINE ROOM ARE OIL FREE.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Engineering
Issued 21 May 1996 Resolved
RENEW DETERIORATED BLACK OIL DISCHARGE PIPE LOCATED IN LOWER ENGINE ROOM_x001C_ AFT PORT SIDE.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER DISCHARGE PIPE FOR REFRIGERATION_x001C_ SYSTEM LOCATED IN THE LOWER ENGINE ROOM STBD SIDE.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 21 May 1996 Resolved
RENEW/REPAIR LEAKING MAIN SEAL FOR MAIN FIRE PUMP LOCATED IN THE ENGINE_x001C_ ROOM STBD SIDE LOWER LEVEL.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 21 May 1996 Resolved
PROVIDE FIREHOSES AND DUAL PURPOSE NOZZLES TO EACH FIRE STATION LOCATED IN_x001C_THE ENGINE ROOM.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED DECKHEAD LOCATED ENGINE ROOM LOWER LEVEL_x001C_ PORT SIDE BENEATH ENGINE CONTROL ROOM. _x001C_ SOLAS 74 (AMENDED) I/11(a)
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Lifesaving
Issued 21 May 1996 Resolved
SECURE LOOSE PRESSURE TANKS LOCATED IN THE #1 DECK HOUSE.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW/REPAIR DETERIORATED WATERTIGHT DOOR LOCATED ON THE MAIN DECK FWD PORTSIDE.(STOWAGE ROOM IN FOCSLE)_x001C_ ICLL 66 I/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 21 May 1996 Resolved
PROVIDE AN APPROPRIATE FIRE EXTINGUISHING ARRANGEMENT APPROVED BY THE_x001C_ ADMINISTRATION FOR THE FORWARD PAINT LOCKER._x001C_ SOLAS 74 (AMENDED) II-2/18.7
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW/REPAIR DETERIORATED WATERTIGHT DOOR LOCATED FORWARD ON THE PORT _x001C_BOAT DECK._x001C_ ICLL 66 1/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Electrical
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE EMERGENCY LIGHTING FOR THE PORT AND STARBOARD _x001C_ LIFEBOAT EMBARKATION STATION._x001C_ SOLAS 60 III/19(a)(ii)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Lifesaving
Issued 21 May 1996 Resolved
RENEW RETRO-REFLECTIVE MATERIAL TO PORT AND STARBOARD LIFEBOAT. LIFEBOATS_x001C_ SHALL BE FITTED WITH RETRO-REFLCETIVE MATERIAL IN ACCORDANCE WITH SOLAS 74_x001C_(AMENDED) III/30.2.7 AND IMO RESOLUTION A. 658(16)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE VENTILATION CLOSURE FOR CO2 ROOM LOCATED ON #3 DECKHOUSE._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW/REPAIR BROKEN VENTILATION LOUVRE FOR EMERGENCY GENERATOR AIR INTAKE.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE VENTILATION CLOSURE FOR EMERGENCY GENERATOR ROOM._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE FIREMAIN HYDRANT LOCATED AFT OF #2 DECK HOUSE._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW/REPAIR DETERIORATED WATERTIGHT DOOR TO BATTERY STORAGE ROOM LOCATED_x001C_ FWD ON THE #2 DECK HOUSE._x001C_ ICLL 66 1/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW MISSING VENTILATION CLOSURE LOCATED PORT SIDE OF #2 DECK HOUSE._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 21 May 1996 Resolved
UPDATE VESSELS FIRE CONTROL PLAN TO INCLUDE THE LOCATION OF ALL FIRE _x001C_ DAMPERS AND VENTILATION SHUTDOWNS THROUGHOUT THE VESSEL._x001C_ SOLAS 74 (AMENDED) II-2/20
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Fire Fighting
Issued 21 May 1996 Resolved
PROVIDE ON BOARD VESSEL, INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL_x001C_INSTALLATIONS/EQUIPMENT FOR FIGHTING AND CONTAINMENT OF FIRE._x001C_ SOLAS 74 (AMENDED) II-2/20
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Fire Fighting
Issued 21 May 1996 Resolved
CONDUCT A SATISFACTORY FIRE AND ABANDON SHIP DRILL TO THE SATISFACTION OF_x001C_ THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Lifesaving
Issued 21 May 1996 Resolved
PROVIDE A MEANS FOR BRINGING THE LIFEBOATS AGAINST THE SHIPS SIDE AND THEREHOLDING THEM SO THAT PERSONS MAY BE SAFETLY EMBARKED._x001C_ SOLAS 60 III/29(i)
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED CLASS "A" BULKHEAD LOCATED FWD STBD SIDE OF_x001C_DOMESTIC REEFER ROOM ON MAIN DECK. _x001C_ SOLAS 74(AMENDED) I/11(a)
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED DECKHEAD LOCATED IN THE ENGINE ROOM ABOVE_x001C_ THE MAIN DIESEL AIR START CYLINDERS, FWD OF #4 GENERATOR. _x001C_ SOLAS 74 (AMENDED) I/11(a)
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Engineering
Issued 21 May 1996 Resolved
PROVIDE ONBOARD VESSEL A STANDARD DISCHARGE CONNECTION THAT COMPLIES WITH_x001C_ THE REQUIREMENTS OF MARPOL 73/789 ANNEX I REGULATION 19.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW AS ORIGINAL, KNIFE EDGE TO ENGINE ROOM WATERTIGHT DOOR LOCATED ON THEPOOP DECK. THE KNIFE EDGE HAS BEEN ALTERED TO ACCOMODATE AN ELECTRICAL_x001C_ CABLE.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED CLASS "A" BULKHEAD LOCATED ON THE POOP DECK_x001C_IN WAY OF ENGINE ROOM ACCESS.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED PIPE BRACKETS TO HORIZONTAL BALLAST PIPE_x001C_ LOCATED ON THE STERN.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 21 May 1996 Resolved
PROVIDE A FIREHOSE AND NOZZLE FOR THE FIRESTATION LOCATED CENTERLINE ON THEPOOP DECK._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW MISSING VENTILATION CLOSURE TO NATURAL VENTILATION DUCT LOCATED AFT_x001C_ PORT SIDE ON POOP DECK._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE VENTILATION CLOSURE LOCATED PORT SIDE FWD ON THE_x001C_ MAIN DECK HOUSE._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Electrical
Issued 21 May 1996 Resolved
RENEW BROKEN COVER FOR EMERGENCY LIGHT LOCATED FWD PORT SIDE OF MAIN DECK_x001C_ HOUSE.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 21 May 1996 Resolved
RENEW MISSING FIREHOSE TO FIREBOX LOCATED ON THE FWD SIDE STBD ON THE MAIN_x001C_DECK HOUSE._x001C_ SOLAS 74(AMENDED) II-2/21
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 21 May 1996 Resolved
RENEW MISSING PORTABLE FIRE EXTINGUISHER TO STORAGE ROOM LOCATED PORT SIDE_x001C_OF #3 DECK HOUSE._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW/REPAIR DETERIORATED KNIFE EDGE FOR WATERTIGHT DOOR TO EMERGENCY_x001C_ GENERATOR ROOM._x001C_ ICLL 66 1/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW/REPAIR DETERIORATED DECK IN AFT CARGO LIFT CONTROL ROOM ON #3 DECK HOUSE.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW MISSING VENTILATION CLOSURE FOR THE EMERGENCY BATTERY ROOM LOCATED_x001C_ AFT ON THE BRIDGE DECK._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Electrical
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE LIGHTING IN NUMEROUS FAN ROOMS, STOWAGE ROOMS, ETC.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW MISSING VENTILATION CLOSURES TO VENTILATION DUCTS LOCATED ON THE_x001C_ FLYING BRIDGE. (4) _x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE MUSHROOM VENTS LOCATED STBD SIDE ON THE FLYING _x001C_ BRIDGE._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Lifesaving
Issued 21 May 1996 Resolved
PROVIDE AT LEAST ONE LIFEBOUY ON EACH SIDE OF THE SHIP FITTED WITH A _x001C_ BOUYANT LIFELINE OF AT LEAST 15 FATHOMS (27.5 METERS) IN LENGTH._x001C_ SOLAS 60 III/21(d)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 21 May 1996 Resolved
RENEW DETERIORATED FIREBOX LOCATED ON THE STARBOARD BRIDGE WING._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW MISSING VENTILATION CLOSURE TO NATURAL VENTILATION DUCT LOCATED STBD_x001C_SIDE FWD ON BRIDGE WING._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Lifesaving
Issued 21 May 1996 Resolved
PROVIDE ON BOARD VESSEL, TRAINING MANUAL FOR LIFESAVING APPLIANCES._x001C_ SOLAS 74 (AMENDED) III/18.2/51
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Navigation
Issued 21 May 1996 Resolved
PROVIDE ON BOARD VESSEL, ADEQUATE, UPDATED NAVIGATION CHARTS FOR THE _x001C_ INTENDED VOYAGE._x001C_ SOLAS 74 (AMENDED) V/20
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 21 May 1996 Resolved
RENEW ALL DEFECTIVE FIRE HOSES THROUGHOUT THE VESSEL.NOTED OVER 80% OF_x001C_ THOSE CHECKED WERE HOLED. _x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 21 May 1996 Resolved
RENEW DETERIORATED FIRE BOX LOCATED ON THE PORT BRIDGE WING._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW/REPAIR DETERIORATED WATER TIGHT DOORS (3) LOCATED ON THE PORT BRIDGE_x001C_DECK._x001C_ ICLL 66 ANNEX 1/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Lifesaving
Issued 21 May 1996 Resolved
RENEW/REPAIR DETERIORATED (HOLED) PORT LIFEBOAT. LIFEBOAT HAS A FIBERGLASSPATCH ON THE STBD SIDE THAT IS CRACKED._x001C_ SOLAS 60 III/4(c)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW/REPAIR DETERIORATED WATERTIGHT DOOR TO COMMUNICATION ROOM LOCATED ON_x001C_THE PORT BOAT DECK._x001C_ ICLL 66 1/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Electrical
Issued 21 May 1996 Resolved
REMOVE BATTERIES STORED IN VENTILATION ROOM LOCATED ON THE PORT BOAT DECK._x001C_SOLAS 60 II/27(a)(ii)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE NATURAL VENTILATION DAMPERS (3) LOCATED ON THE PORTBOAT DECK._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE VENTILATION DOORS (2) LOCATED ON THE PORT BOAT DECKSOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW/REPAIR DETERIORATED KNIFE EDGE FOR WATERTIGHT DOOR LOCATED AFT ON THEPORT BOAT DECK._x001C_ ICLL 66 1/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW/REPAIR DETERIORATED KNIFE EDGE FOR WATERTIGHT DOOR TO INCINIRATOR_x001C_ ROOM LOCATED AFT ON THE PORT BOAT DECK._x001C_ ICLL 66 1/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 21 May 1996 Resolved
RENEW BROKEN FIRE EXTINGUISHER LOCATED IN THE VENTILATION ROOM AFT ON THE _x001C_PORT BOAT DECK._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE MUSHROOM VENT LOCATED AFT ON THE PORT BOAT DECK._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Lifesaving
Issued 21 May 1996 Resolved
RENEW ALL DEFECTIVE RING LIFEBOUYS. PROVIDE TWELVE RING LIFEBOUYS ON STATION IN SERVICEABLE CONDITION AND AVAILABLE FOR IMMEDIATE USE._x001C_ SOLAS 74 (AMENDED) III/19.2
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Lifesaving
Issued 21 May 1996 Resolved
RENEW DEFECTIVE WATERLIGHTS TO RING LIFEBUOYS. PROVIDE SIX WATERLIGHTS_x001C_ ATTACHED TO RING LIFEBOUYS IN A SERVICEABLE CONDITION AND AVAILABLE FOR_x001C_ IMMEDIATE USE._x001C_ SOLAS 74 (AMENDED) III/19.2
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Lifesaving
Issued 21 May 1996 Resolved
PROVIDE A WEAKLINK TO THE PAINTERS OF ALL LIFERAFTS TO ENSURE THE LIFERAFTSWILL RELEASE FROM A SINKING VESSEL._x001C_ SOLAS 74 (AMENDED) III/26.3
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW/REPAIR WASTED AND INOPERABLE VENTILATION CLOSURES (2) LOCATED CENTER_x001C_LINE AFT ON THE BOAT DECK._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW/REPAIR DETERIORATED WATERTIGHT DOOR TO INTERNAL PASSAGEWAY FROM AFT_x001C_ BOAT DECK CENTER._x001C_ ICLL 66 1/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Electrical
Issued 21 May 1996 Resolved
REMOVE UNSAFE ELECTRICAL CABLE LOCATED AFT CENTERLINE ON BOAT DECK._x001C_ SOLAS 60 II/27
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE VENTILATION CLOSURE LOCATED STBD SIDE AFT ON BOAT _x001C_DECK._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE WATERTIGHT DOOR LOCATED AFT ON THE STBD BOAT DECK._x001C_ICLL 66 1/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE VENTILATION CLOSURE DOORS (2) LOCATED ON THE STBD _x001C_BOAT DECK._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW/REPAIR DETERIORATED KNIFE EDGE TO WATERTIGHT DOOR LOCATED AFT ON STBDBOAT DECK._x001C_ ICLL 66 1/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW DETERIORATED WATERTIGHT DOOR TO COMPARTMENT HOUSING DIRTY WATER TANK_x001C_LOCATED STBD SIDE BOAT DECK._x001C_ ICLL 66 1/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE FIRE MAIN HYDRANT VALVE LOCATED ON THE STBD BOAT _x001C_ DECK._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW/REPAIR MISSING DOG TO NATURAL VENTILATION CLOSURE LOCATED AFT PORT_x001C_ SIDE ON THE "D" DECK._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 21 May 1996 Resolved
RENEW MISSING FIREHOSE TO FIRE STATION LOCATED ON THE "D" DECK CENTERLINE._x001C_SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
REPAIR BROKEN HINGE TO NATURAL VENTILATION CLOSURE LOCATED ON THE "D" DECK_x001C_CENTERLINE. _x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW MISSING WATERTIGHT DOOR TO GALLEY LOCATED ON THE "D" DECK._x001C_ ICLL 66 1/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW MISSING DRAIN PIPES ON STBD SIDE MAIN DECK. OVERFLOW IS CURRENTLY_x001C_ POURING FROM HOLES IN THE MAIN DECKHOUSE BULKHEAD.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW MISSING WATERTIGHT DOORS TO PILOT HOUSE LOCATED ON PORT AND STBD_x001C_ BRIDGE WINGS._x001C_ ICLL 66 1/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW/REPAIR DETERIORATED WATERTIGHT DOOR TO LIFEBOAT PROVISION ROOM_x001C_ LOCATED AFT PORT SIDE BOAT DECK._x001C_ ICLL 66 1/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 21 May 1996 Resolved
RENEW DETERIORATED KNIFE EDGE TO WATERTIGHT DOOR LOCATED ON THE STBD BRIDGEDECK, AFT OF PILOT HOUSE._x001C_ ICLL 66 ANNEX 1/12
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Electrical
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE DECK LIGHTING THROUGHOUT THE VESSEL._x001C_
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW MISSING VENTILATION CLOSURES FOR THE PORT AND STARBOARD ENGINE ROOM_x001C_ VENTILATION EXHAUST VENTS LOCATED PORT AND STARBOARD AFT ON THE BRIDGE DECKSOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 21 May 1996 Resolved
RENEW/REPAIR INOPERABLE NATURAL VENTILATION CLOSURE LOCATED AFT ON THE PORTSIDE OF THE BRIDGE DECK._x001C_ SOLAS 60 II/47(a)
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Navigation
Issued 25 January 1994 Resolved
MSO TAMPA PERSONNEL FOUND WHILE CONDUCTING AN ANNUAL EXAMINATION THE WARNING STATEMENT MISSING FROM THE MANUVERING FACT SHEET. THE MASTER WAS ADVISED TO CORRECT THIS BEFORE NEXT U.S. PORT CALL.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Documentation
Issued 25 January 1994 Resolved
DURING THE ANNUAL EXAMINATION IT WAS FOUND THAT THE OIL TRANSFER PROCEDURESWERE INCOMPLETE: PROCEDURES MISSING LIST OF EACH PRODUCT TRANSFERRED, AND DESCRIPTION OF EACH OIL TRANSFER SYSTEM.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Documentation
Issued 25 January 1994 Resolved
DURING THE ANNUAL EXAMINATION IT WAS NOTED THAT THE VESSEL HAD NO POLLUTIONPLACARD POSTED.
Condition: Unknown
Due 27 January 1994
Resolved 28 January 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.