← All vessels
BLACKSEA POYRAZ
BLACKSEA POYRAZ is a 1973 freight ship. The Coast Guard has recorded 23 inspections since 1984, most recently in June 1996, along with 114 deficiencies and 2 operational controls.
Records from 1984 to 1996. Most recent: inspection, 19 June 1996.
- Built
- 1973
- Last inspected
- 19 June 1996
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 114 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7334577 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226443
Flag
PANAMA
—
Maury page id
psix-226443
Inspections, by type
…with no type recorded23
Years with a record
12 calendar years (1984–1996)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it2892 - Regulatory (Subpart C or D), Net Ton
8303 - Dead Weight, Ton
4004 - Regulatory (Subpart C or D), Gross Ton
8303 - Dead Weight, Ton
4004 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 23
19 June 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 157140
19 June 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 392509
13 June 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 391068
8 November 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 384569
19 February 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 28927
11 July 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 460486
5 September 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 352958
18 December 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 497819
26 April 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 343237
23 October 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 333255
6 April 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 529878
2 December 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 327122
15 October 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 326168
18 March 1988
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 322031
5 February 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 495585
6 November 1987
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 319394
25 September 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 318931
10 March 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 314862
16 October 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 454152
25 March 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 307625
4 February 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 440365
4 March 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 300627
2 June 1984
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 296510
Deficiency record · 114
Fire Fighting
Issued 19 June 1996
Resolved
RENEW PORTABLE FIRE EXTINGUISHER LOCATED AT LOWER LEVEL, PORT SIDE OF ENGINE ROOM IN WAY OF LADDER._x001C_ SOLAS 74 (AMENDED) II-2/21
Construction/Loadline
Issued 19 June 1996
Resolved
CONDUCT PERMANENT REPAIRS TO DETERIORATED OVERHEAD DECK LOCATED AT UPPER LEVEL OF ENGINE ROOM, AFT, PORT SIDE._x001C_ SOLAS 74 (AMENDED) I/11(a)
Fire Fighting
Issued 13 June 1996
Resolved
Replace sprinkler nozzles in the paint locker with a dry system type sprinkler nozzle.
Fire Fighting
Issued 13 June 1996
Resolved
Repair bulkhead penatration to be air tight in paint locker from recent installation of water sprinkler system.
Navigation
Issued 13 June 1996
Resolved
Update charts (11324, 11327, 11328, 11329), Light List, Coast Pilot.
Electrical
Issued 13 June 1996
Resolved
Repair explosion-proof light in battery compartment.
Electrical
Issued 13 June 1996
Resolved
Properly secure batteries in battery compartment.
Electrical
Issued 13 June 1996
Resolved
Place protective coverings for light fixtures in main deck house and machinery spaces.
Fire Fighting
Issued 13 June 1996
Resolved
Professionally service fixed CO2 system. Provide Coast Guard with service report.
Documentation
Issued 13 June 1996
Resolved
Place onboard an approved flag state/updated SOPEP.
Documentation
Issued 13 June 1996
Resolved
Place onboard one Third Class Engineer IAW Safe Manning document.
Lifesaving
Issued 8 November 1995
Resolved
REPAIR/RENEW LIGHTING FOR ILLUMINATING THE LIFEBOAT AND LIFERAFTS AND THEIRLAUNCHING GEAR DURING PREPARATION FOR AND THE PROCESS OF LAUNCHING AND ALSOFOR ILLUMINATING THE WATER INTO WHICH THE LIFEBOATS/LIFERAFTS ARE LAUNCHED UNTIL THE PROCESS OF LAUNCHING IS COMPLETE IAW SOLAS 74(AMENDED) III/11.4.
Documentation
Issued 8 November 1995
Resolved
PROVIDE SAFE MANNING DOCUMENT ISSUED BY FLAG ADMINISTRATION IN ACCORDANCE_x001C_ WITH SOLAS 74(AMENDED)V/13.
Lifesaving
Issued 8 November 1995
Resolved
PROVIDE MUSTER LIST AND EMERGENCY INSTRUCTIONS IN ACCORDANCE WITH SOLAS 74_x001C_(AMENDED) III/8. MUSTER LISTS COMPLYING WITH THE REQUIREMENTS OF REGULATION53 SHALL BE EXHIBITED IN CONSPICUOUS PLACES THROUGHOUT THE VESSEL.
Fire Fighting
Issued 8 November 1995
Resolved
PROVIDE PORTABLE FIRE EXTINGUISHERS FOR EACH SPACE IN ACCORDANCE WITH_x001C_ APPROVED FIRE CONTROL PLAN.
Fire Fighting
Issued 8 November 1995
Resolved
SERVICE ALL PORTABLE EXTINGUISHERS BY AN APPROVED RECOGNIZED SERVICING_x001C_ FACILITY/COMPANY. NOTED NUMEROUS EXTINGUISHERS WERE EXTINGUISHED AND/OR_x001C_ IN DISREPAIR. SEE SOLAS 74 (AMENDED) II-2/21.
Fire Fighting
Issued 8 November 1995
Resolved
REPAIR/RENEW DEFECTIVE FIRE HYDRANT VALVES THROUGHOUT THE VESSEL. NOTED_x001C_ SEVERAL VALVES THAT WERE INOPERABLE ON MAIN DECK AND IN DECK HOUSE FIRE_x001C_ STATIONS. SEE SOLAS 74 (AMENDED) II-2/21
Documentation
Issued 8 November 1995
Resolved
PROVIDE SHIPBOARD OIL POLLUTION EMERGENCY PLAN IN ACCORDANCE WITH 33 CFR_x001C_ 151.29 AND MARPOL 73/78 ANNEX I REGULATION 26. VESSEL IS RESTRICTED FROM_x001C_ BUNKERING OPERATIONS.
Documentation
Issued 8 November 1995
Resolved
PROVIDE LETTER OF UNDERTAKING FOR VIOLATION OF 33 C.F.R. 151.29, FAILURE_x001C_ TO HAVE ON BOARD VESSEL A VALID SHIPBOARD OIL POLLUTION EMERGENCY PLAN _x001C_ (SOPEP). AMOUNT OF LOU IS DETERMINED BY $5,000 PER DAY WITH A MAXIMUM OF_x001C_ $25,000 THAT VESSEL IS IN NONCOMPLIANCE.
Documentation
Issued 8 November 1995
Resolved
PROVIDE OIL TRANSFER PROCEDURES IN ACCORDANCE WITH 33 CFR 155.720
Navigation
Issued 8 November 1995
Resolved
PROVIDE ON BOARD VESSEL CURRENT CHARTS AND NAUTICAL PUBLICATIONS FOR U.S._x001C_ WATER AND INTENDED VOYAGE IN ACCORDANCE WITH 33 CFR 164.33 AND SOLAS 74_x001C_ (AMENDED) V/20.
Lifesaving
Issued 8 November 1995
Resolved
RENEW OUTDATED HYDROSTATIC RELEASE TO EPIRB LOCATED ON UPPER BRIDGE DECK._x001C_ SEE SOLAS 74 (AMENDED) IV/7.
Documentation
Issued 8 November 1995
Resolved
PROVIDE LETTER OF UNDERTAKING FOR ALLEGED VIOLATION OF 33 CFR 164.33 (a)(1)(2),(b) AND 33 CFR 164.33 (a)(2)-(3), FAILURE TO HAVE CURRENT CHARTS ON_x001C_ BOARD AND FAILURE TO HAVE OTHER REQUIRED NAUTICAL PUBLICATIONS ON BOARD IN_x001C_THE AMOUNT OF $6,000.
Lifesaving
Issued 8 November 1995
Resolved
RENEW DEFECTIVE SATELLITE EMERGENCY POSITION INDICATING RADIO BEACON(EPIRB)LOCATED ON UPPER BRIDGE DECK. SEE SOLAS 74 AMENDED IV/7
Lifesaving
Issued 8 November 1995
Resolved
RENEW OUTDATED HYDROSTATIC RELEASE TO PORT AND STARBOARD INFLATABLE LIFE_x001C_ RAFT INSTALLATION. SEE SOLAS 74 (AMENDED) III/19.8.1.
Lifesaving
Issued 8 November 1995
Resolved
RENEW ALL EIGHT RING LIFEBUOYS THROUGHOUT VESSEL THAT ARE DETERIORATED._x001C_ SEE SOLAS 74 (AMENDED) III/19.2
Lifesaving
Issued 8 November 1995
Resolved
AT LEAST ONE LIFEBUOY ON EACH SIDE ON THE SHIP SHALL BE FITTED WITH A_x001C_ BUOYANT LIFELINE IN ACCORDANCE WITH SOLAS 74 (AMENDED) III/7.1.2
Lifesaving
Issued 8 November 1995
Resolved
INSTALL RETRO-REFLECTIVE MATERIAL TO ALL RING LIFEBUOYS IN ACCORDANCE WITH_x001C_SOLAS 74 (AMENDED) III/30.2.7
Construction/Loadline
Issued 8 November 1995
Resolved
RENEW AS ORIGINAL DETERIORATED WATERTIGHT DOOR LOCATED ON MAIN DECK AFT PORT SIDE IN WAY OF DECK HOUSE ENTRANCE.
Fire Fighting
Issued 8 November 1995
Resolved
RENEW AS ORIGINAL DETERIORATED CO2 CYLINDER BANK SUPPORT BRACKET (VERTICLE)AND ALL DETERIORATED CYLINDER SUPPORTS.
Construction/Loadline
Issued 8 November 1995
Resolved
RENEW AS ORIGINAL DETERIORATED VENT TRUNK LOCATED IN STARBOARD DECK WINCH MACHINERY ROOM. FIRE BOUNDRY HAS BEEN COMPROMISED DUE TO DETERIORATED.
Construction/Loadline
Issued 8 November 1995
Resolved
RENEW AS ORIGINAL DETERIORATED DECK HOUSE BULKHEAD TO MAINTAIN COAMING INTERGRITY FROM CARGO DECK.
Fire Fighting
Issued 8 November 1995
Resolved
PROVIDE KEY BOX FOR CO2 PULL STATION OUTSIDE CO2 STORAGE ROOM TO SYSTEM IS AVAILABLE FOR IMMEDIATE USE.
Construction/Loadline
Issued 8 November 1995
Resolved
RENEW AS ORIGINAL DETERIORATED AFT CO2 COMPARTMENT BULKHEAD. THE FIRE BOUNDRY HAS BEEN COMPROMISED DUE TO THIS DETERIORATION.
Fire Fighting
Issued 8 November 1995
Resolved
PROVIDE AND POST OPERATING INSTRUCTIONS FOR FIXED CO2 FIRE SUPPRESSION SYSTEM IN THE LANGUAGE /LANGUAGES UNDERSTOOD BY THE CREW IN WAY OF CO2 ROOM.
Deck/Cargo
Issued 8 November 1995
Resolved
RENEW MISSING VENT CLOSURE ABOVE WATERTIGHT DOOR PORT SIDE AFT MAIN CARGO DECK IN WAY OF DECK HOUSE ENTRANCE.
Construction/Loadline
Issued 8 November 1995
Resolved
RENEW DETERIORATED DECKHEAD ABOVE CO2 COMPARTMENT ENTRANCE PORTSIDE.
Navigation
Issued 8 November 1995
Resolved
PROVIDE AND POST SIMPLE OPERATING INSTRUCTIONS WITH BLOCK DIAGRAMS, SHOWINGTHE CHANGEOVER PROCEDURES FOR REMOTE STEERING GEAR CONTROL SYSTEMS AND STEERING GEAR POWER UNITS, PERMANENTLY DISPLAYED ON NAVIGATING BRIDGE AND IN THE STEERING GEAR COMPARTMENT.
Documentation
Issued 8 November 1995
Resolved
PROVIDE VALID CERTIFICATES OF COMPETENCY FOR VESSELS OFFICERS ISSUED AND_x001C_ ENDORSED BY FLAG ADMINISTRATION IN ACCORDANCE WITH STCW 1978 ARTICLES.
Documentation
Issued 8 November 1995
Resolved
PROVIDE UPDATED FIRE CONTROL PLAN IN ACCORDANCE WITH SOLAS 74 (AMENDED)_x001C_ II-2/20
Lifesaving
Issued 8 November 1995
Resolved
PROVIDE EVIDENCE THAT LIFEBOAT DAVIT FALLS HAVE BEEN RENEWED WITHIN 5 YEARSAND END FOR ENDED WITHIN 30 MONTHS. SEE SOLAS 74 (AMENDED) III/19.4
Lifesaving
Issued 8 November 1995
Resolved
THE LIFEBOAT ENGINE,TRANSMISSION AND ENGINE ACCESSORIES SHALL BE ENCLOSED_x001C_ IN A FIRE-RETARDANT CASING.
Construction/Loadline
Issued 8 November 1995
Resolved
RENEW DETERIORATED DECKHEAD IN STEERING GEAR COMPARTMENT AND REWELD INSERT IN DECKHEAD PORT SIDE AFT.
Navigation
Issued 8 November 1995
Resolved
PROVE OPERATION EMERGENCY STEERING W/TRICK WHEEL FROM STEERING GEAR COMPARTMENT.
Navigation
Issued 8 November 1995
Resolved
REPAIR ALL LEAKS ON HYDRUALIC FITTING/RAMS TO STEERING GEAR UNIT THEN REMOVE ALL OIL FROM COMPARTMENT DECK. GENERAL HOUSEKEEPING OF COMPARTMENT IS NEEDED TO REDUCE FIRE HAZARD.
Construction/Loadline
Issued 8 November 1995
Resolved
RENEW/SEAL WIRE PENETRATION OF FIRE BOUNDRY TO STEERING GEAR COMPARTMENT SOTO MAINTAIN INTEGRITY OF BOUNDRY.
Deck/Cargo
Issued 8 November 1995
Resolved
PROVE THAT POWER VENTILATION IS CAPABLE OF BEING SHUTDOWN FROM OUTSIDE THE VENTILATED SPACE.
Fire Fighting
Issued 8 November 1995
Resolved
RENEW BREATHING APPARATUS AIR BOTTLE TO FIREMAN'S OUTFIT LOCATED ON NIVIGATION BRIDGE.
Engineering
Issued 8 November 1995
Resolved
PROVE OPERATION OF REMOTE SHUTDOWNS TO FUEL OIL SUCTION VALVES, OIL TRANSFER PUMP AND OTHER FUEL PUMPS.
Fire Fighting
Issued 8 November 1995
Resolved
REPAIR AND PROVE OPERATION OF EACH FIRE DAMPER.
Construction/Loadline
Issued 8 November 1995
Resolved
RENEW DAMAGED/DETERIORATED BULKWARKS THROUGHOUT VESSEL AND ASSOCIATED FLANGED PLATE BRACKETS AND INTERCOSTAL STIFFENER ANGLES.
Construction/Loadline
Issued 8 November 1995
Resolved
RENEW AS ORIGINAL DETERIORATED DECKHEAD IN MAIN ENGINE STOREROOM STARBOARD SIDE MAIN DECK THATS COMMON WITH GALLEY ABOVE. INTEGRITY OF FIRE BOUNDRY AS BEEN COMPROMISED.
Construction/Loadline
Issued 8 November 1995
Resolved
RENEW AS ORIGINAL DETERIORATED BULKHEAD LOCATED ON #2 MAST HOUSE AFT IN WAYOF ACCESS DOORS.
Construction/Loadline
Issued 8 November 1995
Resolved
RENEW AS ORIGINAL DETERIORATED AFT BULKHEAD ON #1 MAST HOUSE IN WAY OF ACCESS TUNNEL.
Fire Fighting
Issued 8 November 1995
Resolved
RENEW AS ORIGINAL DETERIORATED FIREMAIN PIPING AT THE FOLLOWING LOCATIONS: 1) STBD SIDE FWD OF DECK HOUSE. 2) STBD SIDE MAIN DECK IN WAY OF #2 MAST HOUSE. 3)ATOP #2 MAST HOUSE. 4)ATOP #1 MAST HOUSE. 5)ALONG #1 CARGO HOLD STBD SIDE APPROX 60FT.
Accommodation/Occupational Safety
Issued 8 November 1995
Resolved
REPAIR/RENEW DETERIORATED EXTERIOR LADDER STEPS THROUGHTOUT VESSEL.
Deck/Cargo
Issued 8 November 1995
Resolved
INSTALL GOOSENECK VENTILATOR FOR NATURAL VENT TO CO2 CYLINDER STORAGE COMPARTMENT.
Deck/Cargo
Issued 8 November 1995
Resolved
INSTALL A MEANS TO CLOSE GOOSENECK VENTILATION LOCATED ATOP #1 AND #2 MAST HOUSE.
Lifesaving
Issued 8 November 1995
Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR PORT LIFEBOAT: 1)TWO BUCKETS W/LANYARD 2)GALVANIZED WIRE STAYS FOR MASTS. 3)SAILS(ORANGE IN COLOR). 4)3 LITERS OF WATER FOR EACH PERSON THE LIFEBOAT IS CERTIFIED TO CARRY. 5)AN OPERABLE MANUAL PUMP. 6)EXPOSURE COVER,FRAMEWORK,CRUTCHES FOR OAR SHALL BE ATTACH.
Lifesaving
Issued 8 November 1995
Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR STARBOARD LIFEBOAT: 1)3 LITERS WATER FOR LIFEBOAT. 2)LOCKER FOR STOWAGE. 3)EXPOSURE COVER. 4)FRAMEWORK FOR COVER. 5)CRUTCHES FRO OARS. 6)SURVIAL MANUAL. 7)TOOLS FOR ENGINE. 8)SEARCHLIGHTS. 9)RADAR RELECTOR.
Lifesaving
Issued 8 November 1995
Resolved
THE TWO SEA PAINTERS FOR EACH LIFEBOAT SHALL BE; ONE SECURED TO THE FORWARDEND OF THE LIFEBOAT W/STROP AND TOZZLE SO THAT IT CAN BE RELEASED AND THE OTHER SHALL BE FIRMLY SECURED TO THE STEM OF THE LIFEBOAT AND READY FOR USE
Lifesaving
Issued 8 November 1995
Resolved
THE DIMENSIONS OF THE LIFEBOAT AND THE NUMBER OF PERSONS WHICH IT IS PERMITTED TO CARRY SHALL BE MARKED ON IT IN CLEAR PERMANENT CHARACTERS ON EACH LIFEBOAT.
Lifesaving
Issued 8 November 1995
Resolved
PROVIDE REQUIRED AMOUNT OF LIFE PRESERVERS W/REQUIRED RETRO-REFLECTIVE MATERIAL, LIGHTS AND WHISTLES AS INDICATED ON CARGO SHIP SAFETY EQUIPMENT CERTIFICATE.
Engineering
Issued 8 November 1995
Resolved
PROVE OPERATION OF OILY WATER SEPERATOR TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Lifesaving
Issued 8 November 1995
Resolved
PROVIDE LINE THROWING APPLIANCE.
Lifesaving
Issued 8 November 1995
Resolved
PROVIDE 12 ROCKET PARACHUTE FLARES IN WHEELHOUSE.
Construction/Loadline
Issued 8 November 1995
Resolved
RENEW AS ORIGINAL DETERIORATED WATERTIGHT BULKHEAD LOCATED ON MAIN DECK SEPERATING WEATHERDECK FROM BOS'N STORAGE COMPARTMENT AND DECK STORAGE LOCKERS.
Fire Fighting
Issued 8 November 1995
Resolved
RENEW AS ORIGINAL DETERIORATED SALT WATER PIPING IN WAY OF FIRE MAIN PIPINGFOR HAWSE PIPE WASHDOWN.
Construction/Loadline
Issued 8 November 1995
Resolved
RENEW DETERIORATED WATERTIGHT ACCESS HATCH COVER ON FORECASTLE LEADING TO BOS'N HOLE BELOW.
Deck/Cargo
Issued 8 November 1995
Resolved
RENEW AS ORIGINAL DETERIORATED GOOSENECK VENTILATORS ON FORECASTLE WITH CLOSURE DEVICE AND/OR BALL CHECK ASSEMBLY AS MARKED.
Documentation
Issued 8 November 1995
Resolved
PROVIDE LETTER OF UNDERTAKING FOR ALLEGED VIOLATION OF 33 CFR 155.720,_x001C_ FAILURE TO HAVE TRANSFER PROCEDURES IN THE AMOUNT OF $2,000.
Deck/Cargo
Issued 8 November 1995
Resolved
RENEW AS ORIGINAL NATURAL VENT CLOSURE/AND LOWER ASSEMBLY LOCATED ON MAIN DECK FOWARD BULKHEAD STARBOARD SIDE. SUPPLY/EXHAUST FOR #1 CARGOHOLD.
Navigation
Issued 8 November 1995
Resolved
REPAIR/RENEW DEFECTIVE/INOPERABLE NAVIGATIONAL LIGHTS. SEE INTERNATIONAL_x001C_ REGULATIONS FOR PREVENTION OF COLLISIONS AT SEA, 1972 (COLREGS)
Lifesaving
Issued 8 November 1995
Resolved
RENEW AND VERIFY PRESENCE/CONDITION OF LIFEBOAT EQUIPMENT TO EACH LIFEBOAT_x001C_IN ACCORDANCE WITH SOLAS 74 (AMENDED) III/41.8
Lifesaving
Issued 8 November 1995
Resolved
REPAIR DETERIORATED SECTIONS OF LIFEBOAT FIBERGLASS COVERING THAT _x001C_ ENCAPSULATES INHERENTLY BUOYANT MATERIAL TO EACH LIFEBOAT.
Accommodation/Occupational Safety
Issued 8 November 1995
Resolved
REPAIR/RENEW ALL VENT CLOSURES TO ENSURE SMOOTH AND WATERTIGHT SEAL. SEE_x001C_ SOLAS 60 II/17.
Accommodation/Occupational Safety
Issued 8 November 1995
Resolved
RENEW/REPAIR AS ORIGINAL DETERIORATED GOOSENECK VENT COWLINGS THROUGHT_x001C_ VESSEL.
Lifesaving
Issued 8 November 1995
Resolved
RENEW RETRO-REFLECTIVE MATERIAL TO PORT AND STARBOARD LIFEBOAT. LIFEBOATS_x001C_ SHALL BEFITTED WITH RETRO-REFLECTIVE MATERIAL IN ACCORDANCE WITH SOLAS 74_x001C_ (AMMENDED) III/30.2.7 AND IMO RESOLUTION A.658(16)
Lifesaving
Issued 8 November 1995
Resolved
CONDUCT SATISFACTORY FIRE AND ABANDON SHIP DRILL TO THE SATISFACTION OF THEATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Deck/Cargo
Issued 8 November 1995
Resolved
REMOVE EXCESS OIL ON DECK OF HYDRAULIC PUMP ROOM FOR DECK CRANES.
Engineering
Issued 8 November 1995
Resolved
REMOVE DUCT TAPE AND REPAIR/RENEW AS ORGINIAL LEAKING OIL SUPPLY LINE LOCATED ON THE PORT SIDE FWD OF PILOT HOUSE.
Electrical
Issued 8 November 1995
Resolved
REPLACE MISSING LIGHT BULB GLASS SHIELDS AND METALLIC GUARDS THROUGHOUT_x001C_ VESSEL.
Lifesaving
Issued 8 November 1995
Resolved
INSTALL RETRO-REFLECTIVE MATERAIL TO PORT AND STARBOARD LIFEBOAT IN ACCORDANCE WITH SOLAS 74(AMENDED) III/30.2.7. FITTING OF RETRO-REFLECTIVE MATERIAL TO LIFEBOAT SHAL BE IN ACCORDANCE WITH IMO RESOLUTION A.658(16)._x001C_ _x001C_
Lifesaving
Issued 8 November 1995
Resolved
PROVIDE THREE 2-WAY VHF RADIOTELEPHONE APPARATUS IN ACCORDANCE WITH SOLAS 74(AMENDED) III/6.2.1.
Fire Fighting
Issued 8 November 1995
Resolved
PROVE OPERATION OF FIRE DETECTION SYSTEM TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR. PROVIDE FOR REVIEW LAST SERVICING REPORT OF SYSTEM.
Fire Fighting
Issued 8 November 1995
Resolved
PAINT LOCKER AND FLAMMABLE LIQUID LOCKER SHALL BE PROTECTED BY AN APPROPRIATE FIRE-EXTINGUISHING ARRANGEMENT IN ACCORDANCE IN ACCORDANCE WITHSOLAS 74(AMENDED) II-2/18.7.
Fire Fighting
Issued 8 November 1995
Resolved
PROVIDE FOR REVIEW INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL INSTALLATIONS/EQUIPMENT FOR FIGHTING AND CONTAINMENT OF FIRE IN ACCORDANCE WITH SOLAS 74(AMENDED) II-2/20.
Lifesaving
Issued 8 November 1995
Resolved
PROVIDE FOR REVIEW TRAINING MANUAL FOR LIFESAVING APPLIANCES IN ACCORDANCE WITH SOLAS 74(AMENDED) III/18.2/51.
Fire Fighting
Issued 8 November 1995
Resolved
PROVIDE FIRE HOSE AND APPROVED FIRE NOZZLE TO EACH FIRE STATION THAT ARE INGOOD CONDITION AND AVAILABLE FOR IMMEDIATE USE. SEE SOLAS 74 (AMENDED)_x001C_ II-2/21
Fire Fighting
Issued 8 November 1995
Resolved
PROVE OPERATION OF EMERGENCY FIRE PUMP.
Lifesaving
Issued 8 November 1995
Resolved
PROVIDE SIX IMMERSION SUITS AND THERMAL PROTECTIVE AIDS IN ACCORDANCE WITH_x001C_SOLAS 74 (AMENDED) III/27.3 AND FLAG ADMINISTRATION ISSUED SAFETY EQUIPMENTCERTIFICATE.
Fire Fighting
Issued 8 November 1995
Resolved
SERVICE FIXED CO2 FIRE SUPPRESSION SYSTEM BY AN AUTHORIZED SERVICING_x001C_ COMPANY TO ENSURE ALL CYLINDERS,PIPING,CONTROLS,ALARMS AND RELEASE MECHANISMS ARE IN GOOD CONDITION AND AVAILABLE FOR IMMEDIATE USE. SEE SOLAS74 (AMENDED) II-2/21
Fire Fighting
Issued 8 November 1995
Resolved
PROVIDE INTERNATIONAL SHORE CONNECTION IN ACCORDANCE WITH SOLAS 74 (AMENDEDII-2/19
Engineering
Issued 8 November 1995
Resolved
PROVIDE STANDARD DISCHARGE CONNECTION IN ACCORDANCE WITH 33 CFR 155.430 ANDMARPOL 73/78 ANNEX V/4
Engineering
Issued 8 November 1995
Resolved
CLEAN ENGINE ROOM TANK TOPS AND BILGES SO THEY ARE FREE OF OIL. COTP ORDER
Lifesaving
Issued 8 November 1995
Resolved
REPAIR/RENEW LEAKING FUEL TANK IN STARBOARD LIFEBOAT. TANK WAS TEMPORARILY REPAIRED WITH PERMANENT REPAIRS TO BE COMPLETED WITHIN 60 DAYS PER CLASS SOCIETY RECOMMENDATION.
Lifesaving
Issued 8 November 1995
Resolved
PROVIDE FOR REVIEW INSTRUCTIONS FOR ON BOARD MAINTENANCE OF LIFESAVING APPLIANCES IN ACCORDANCE WITH SOLAS 74(AMENDED) III/19.3/52
Lifesaving
Issued 8 November 1995
Resolved
RENEW DETERIORATED LIFELINE BECKETED AROUND THE OUTSIDE OF STARBOARD LIFEBOAT.
Lifesaving
Issued 8 November 1995
Resolved
MEANS SHALL BE PROVIDED FOR BRINGING THE LIFEBOATS AGAINST THE VESSEL'S SIDE AND THERE HOLDING THEM SO THAT PERSONS MAY SAFELY EMBARK TO EACH LIFEBOAT. ENSURE BOS'N TACKLE AND TRICING PENDANTS ARE EQUIPPED TO EACH LIFEBOAT. SEE SOLAS 60 III/36
Navigation
Issued 5 September 1992
Resolved
VESSEL'S CHARTS OF THE AREA TO BE TRANSITTED WERE NOT CURRENTLY CORRECTED, IAW UNITED STATES LAWS AND REGULATIONS CONTAINED IN TITLE 33 CODE OF FEDERAL REGULATIONS PART 164.33(A)(1)(ii).
Navigation
Issued 5 September 1992
Resolved
VESSEL'S COAST PILOT OF THE AREA TO BE TRANSITTED WAS NOT CURRENTLY CORRECTED.
Navigation
Issued 5 September 1992
Resolved
VESSEL'S LIGHT LIST FOR THE AREA TO BE TRANSITTED WAS NOT CURRENTLY CORRECTED.
Navigation
Issued 26 April 1991
Resolved
33 CFR 164.33(a)(1)(ii) Vsls charts of the area were not currently corrected._x001C_ _x001C_ _x001C_
Navigation
Issued 26 April 1991
Resolved
33 CFR 164.33(a)(3)(ii) Vsls did not have a Tidal Current Table onboard._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 26 April 1991
Resolved
33 CFR 164.33(a)(2)(i) Vsls Coast Pilot was not currently corrected._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 26 April 1991
Resolved
33 CFR 164.33(a)(2)(ii) Vsls Light List was not currently corrected._x001C_ _x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 2 December 1988
Resolved
VESSEL'S TYPE III MSD'S OVERBOARD DISCHARGE VALVE WAS JAMMED IN THE OPEN POSITION, ALLOWING THE DISCHARGE OF RAW SEWAGE INTO U.S. WATERS.
Navigation
Issued 15 October 1988
Resolved
COPY OF INLAND & INT'L NAVIGATION RULES NOT ONBOARD AS REQUIRED BY 33 CFR 88.05
Accommodation/Occupational Safety
Issued 15 October 1988
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety
Issued 6 November 1987
Resolved
VSL'S MARINE SANITATION DEVICE HAS NOT BEEN CERTIFIED BY THE U.S.C.G., AND THERE IS NO LABEL AFFIXED TO THE DEVICE NOR DOES THE VSL HAVE ANY CERTIFI- CATION LETTER DISPLAYING APPROVAL OF THE DEVICE.
Documentation
Issued 25 September 1987
Resolved
33CFR151.25 THE VESSEL'S OIL RECORD BOOK WAS NOT MAINTAINED.
Accommodation/Occupational Safety
Issued 25 September 1987
Resolved
33CFR159.7 THE VESSEL'S MARINE SANITATION DEVICE WAS NOT CERTIFIED BY THE U.S. COAST GUARD.
Documentation
Issued 25 September 1987
Resolved
33CFR155.720 THE VESSEL DID NOT HAVE OIL TRANSFER PROCEDURES.
Documentation
Issued 10 March 1987
Resolved
IMPROPERLY MAINTAINED OIL RECORD BOOK. NO OIL RECORD BOOK ENTRIES WERE MADEFOR OILY WASTE THAT WERE PERIODICALLY REMOVED FROM THE OILY WASTE TANK AND BURNED IN THE SHIPS BOILER.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.