Records from 1985 to 1998. Most recent: inspection, 7 May 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
7 May 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 415575
27 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 402047
6 October 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 396210
8 November 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 461674
29 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1192379
5 May 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 378004
7 September 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 469776
29 March 1994
Tank Vessel Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1354676
24 March 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 365514
22 May 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 444370
13 October 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 353765
15 July 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 645681
9 July 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 446363
11 October 1991
Deficiency Check · Certificate of Compliance
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1010091
3 July 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 490891
15 December 1989
MARPOL Annex I Examination · Certificate of Compliance
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 901247
14 January 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1199866
15 December 1988
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1350169
8 December 1988
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 443165
20 April 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 436323
25 August 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 318142
25 August 1987
MARPOL Annex II Examination · Certificate of Compliance
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1001736
27 March 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 440504
10 June 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 309315
10 June 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1305600
7 April 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 529549
Unknown
Issued 7 May 1998
No resolution recorded
MAKE PERMANENT REPAIR TO MSD TANK PRIOR TO ENTRY TO NEXT U.S. PORT. TANK CURRENTLY HAVE SOFT PATCH.
Condition: Unknown
Due 8 May 1998 — due date passed with no resolution recorded
Lifesaving
Issued 7 May 1998
No resolution recorded
REPAIR OR RENEW PORTABLE OXYGEN METER.
Condition: Unknown
Due 10 May 1998 — due date passed with no resolution recorded
Deck/Cargo
Issued 7 May 1998
No resolution recorded
INSTALL AUDIBLE AND VISUAL OVERFILL ALARMS ON CARGO DECK PRIOR TO LOADING OIL CARGOES IN U.S. WATERS.
Condition: Unknown
Due 8 May 1998 — due date passed with no resolution recorded
Fire Fighting
Issued 11 October 1991
Resolved
PROVIDE AND HYDROSTATICALLY TEST FIRE HOSES AS NEEDED PRIOR TO DEPARTURE FROM PORT ARTHUR, TX INSPECTION ZONE.
Condition: Unknown
Due 30 January 1992
Resolved 30 January 1992
Fire Fighting
Issued 11 October 1991
Resolved
INSTALL FIXED FIRE EXTINGUISHING SYSTEM IN PAINT LOCKER IN ACCORDANCE WITH 46 CFR 34.05-5 (a)(3) AT NEXT DRYDOCKING.
Condition: Unknown
Due 11 October 1991
Resolved 11 October 1991
Engineering
Issued 11 October 1991
Resolved
PROVIDE FLAG STATE CERTIFICATION THAT OILY WATER SEPARATOR IS OPERATING IN ACCORDANCE WITH RESOLUTION A.393(X) PRIOR TO NEXT US VOYAGE.
Condition: Unknown
Due 11 October 1991
Resolved 11 October 1991
Deck/Cargo
Issued 14 January 1989
Resolved
MAKE PERMENANT REPAIRS TO PIPELINE WHICH ALLOWS DISCHARGE OF SLOP TO SHORE.(SMALL DIAMATER LINE) TEMP. REPAIRS EFFECTED, LOCATION STBD. SIDE APPROX. 30' AFT OF CROSSDECK HEADER AT PIPE SUPPORT MEMBER, WHICH HAD CAUSED A SMALL HOLE ON BOTTOM OF PIPE. MARPOL73/78ANNEXIREG18/4/B;33CFR157.11(D)
Condition: Unknown
Due 14 January 1989
Resolved 14 January 1989
Fire Fighting
Issued 15 December 1988
Resolved
MAKE PERMANENT REPAIR TO FIRE MAIN IN WAY OF FIRE PUMP AT FORWARD BULKHEAD OF ENGINEROOM.
Condition: Unknown
Due 15 December 1988
Resolved 15 December 1988