MAURY USCG vessel records Sign in
← All vessels

GRIS

GRIS is a 1973 tank ship. The Coast Guard has recorded 29 inspections since 1990, most recently in June 1999, along with 34 deficiencies — 1 with no resolution recorded —.

Records from 1990 to 1999. Most recent: inspection, 15 June 1999.

Built
1973
Last inspected
15 June 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7350052 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226559
Flag
PANAMA
—
Maury page id
psix-226559

Inspections, by type

…with no type recorded20
…past their stated due date1
Years with a record 10 calendar years (1990–1999)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2608 - Regulatory (Subpart C or D), Net Ton
1326 - Convention (Subpart B), Net Ton
4550 - Dead Weight, Ton
6524 - Displacement, Ton
3276 - Regulatory (Subpart C or D), Gross Ton
3121 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 29

15 June 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 429526
28 May 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 429218
19 August 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 419152
19 August 1998 Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 798252
23 September 1997 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 408284
12 August 1997 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 783492
7 August 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 406599
20 July 1997 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 782700
25 September 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 395719
23 August 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 394370
20 June 1996 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 392336
31 August 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 382165
16 August 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 381623
6 February 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 673020
12 January 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 374193
29 December 1994 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 373788
16 July 1994 Tank Vessel Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 863854
24 May 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 367097
13 May 1994 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 470020
13 May 1994 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 536349
15 January 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 363943
3 September 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1138998
27 July 1993 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1459814
22 April 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 945676
4 September 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 656105
31 August 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 345676
31 August 1991 Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 941130
27 June 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 337854
27 June 1990 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1216327

Deficiency record · 34

Fire Fighting
Issued 19 August 1998 Resolved
#3 fire hydrant leaking.
Condition: Unknown
Due 20 August 1998
Resolved 26 August 1998
Documentation
Issued 19 August 1998 Resolved
Vessel did not have a licensed 3rd engineer. 4th engineer was working as a 3rd engineer.
Condition: Unknown
Due 20 August 1998
Resolved 26 August 1998
Electrical
Issued 19 August 1998 No resolution recorded
Seawater cooling lines are for generator in lower engine room leaking.
Condition: Unknown
Due 19 September 1998 — due date passed with no resolution recorded
Construction/Loadline
Issued 19 August 1998 Resolved
Temporary patch for overboard deck scupper going through #4 cargo tank.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Lifesaving
Issued 7 August 1997 Resolved
REPAIR SPEED CONTROL HANDLE ON PORT SIDE LIFEBOAT. (SOLAS 60 REG. 9 (a)iii_x001C_(2)). CORRECT TO THE SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Construction/Loadline
Issued 7 August 1997 Resolved
REPAIR AFT GALLEY DOOR FOR INTEGRITY/ FIRE BOUNDARY. (ICLL ANNEX I CHAPTER 12). REPAIR TO THE SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Construction/Loadline
Issued 7 August 1997 Resolved
MAKE CARGO PUMP ROOM/BALLAST TANK SAFE FOR ENTRY/USCG INSPECTION. (MVI. POLICY LETTER NO. 8-92) CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 25 September 1997
Resolved 25 September 1997
Navigation
Issued 23 August 1996 Resolved
PLACE GUARD OVER FLYWHEEL ASSEMBLY TO EMERGENCY FIRE PUMP. (ILO 147) CORRECT BY 23 SEPTEMBER 1996.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Engineering
Issued 23 August 1996 Resolved
INTERNATIONAL DISCHARGE CONNECTION INSTALLED IN WRONG PIPE/ SIDE. STARBOARDSIDE PIPING UNABLE TO PUMP SLUDGE. (MARPOL 73/78/90 ANNEX I REG.19).
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Documentation
Issued 23 August 1996 Resolved
VESSEL MISSING TIDE CURRENT TABLES CURRENT EDITION. (33 C.F.R. 164.33) CORRECT PRIOR TO 23 SEPTEMBER 1996.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Accommodation/Occupational Safety
Issued 20 June 1996 Resolved
MAKE PERMANENT REPAIRS TO THE MSD SEA WATER INTAKE PIPING SYSTEM LOCATED INTHE ENGINEROOM. MULTIPLE SOFT PATCHES AND LEAKS THROUGHOUT SYSTEM. REPAIRS TO BE MADE TO SATISFACTION OF CLASS AND PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Deck/Cargo
Issued 20 June 1996 Resolved
MAKE PERMANENT REPAIRS TO THE FWD. DECK WINCH HYDRAULIC CONTROLS. LEAKING FLUID. REPAIRS TO BE MADE TO THE SATISFACTION OF CLASS AND PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Engineering
Issued 16 August 1995 Resolved
Outstanding and over due class requirement #CC036 30APRIL 95, (replace flexible supply and return hoses to auxiliary diesel engines by 30 July 95.
Condition: Unknown
Due 1 September 1995
Resolved 1 September 1995
Deck/Cargo
Issued 16 August 1995 Resolved
Make permanent repairs to cargo vent piping, from cargo tanks number 2 and 3 port, (Temporary patch in place).
Condition: Unknown
Due 1 September 1995
Resolved 1 September 1995
Unknown
Issued 16 August 1995 Resolved
Hand radios used durring transfer operations while inspectors were on board, not intrinsically safe.
Condition: Unknown
Due 18 August 1995
Resolved 21 September 1995
Deck/Cargo
Issued 16 August 1995 Resolved
Pressure test Cargo Hoses at 225 PSI (provide manufacture documention of minimum design burst pressure to determine if hoses are acceptable for current service). Hoses belonging to ship had no markings on them and there were no records of any pressure tests done on board.
Condition: Unknown
Due 18 August 1995
Resolved 21 September 1995
Navigation
Issued 12 January 1995 Resolved
The vessel's Rudder Angle indicator was missing the locking device.
Condition: Unknown
Due 26 January 1995
Resolved 26 January 1995
Documentation
Issued 12 January 1995 Resolved
The vessel's Oil Transfer Procedures were missing the list of oil products_x001C_transferred to and from the vessel and procedures for emptying manifold containment.
Condition: Unknown
Due 26 January 1995
Resolved 26 January 1995
Fire Fighting
Issued 27 July 1993 Resolved
Provide foam analysis report of replace fire fighting foam._x001C_ Provide prior to cargo operations at next U.S. Port.
Condition: Unknown
Due 27 September 1993
Resolved 17 September 1993
Fire Fighting
Issued 27 July 1993 Resolved
Propery close opening in cableway between paint locker and cargo control room. SOLAS 74 II-2 Reg. 44
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Lifesaving
Issued 27 July 1993 Resolved
Provide electrical grade matting for generator switchboard in accordance with SOLAS 74 II-1 Reg. 45
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Accommodation/Occupational Safety
Issued 27 July 1993 Resolved
Prove proper operation of supply fan for forward cargo pump room._x001C_
Condition: Unknown
Due 17 September 1993
Resolved 17 September 1993
Construction/Loadline
Issued 22 April 1992 Resolved
MAKE AVAILABLE FOR CG INSPECTION NEXT ARRIVAL US WATERS #25 HIGH/CARGO/BALLAST TANKS AND HAVE GAS FREE CHEMIST AVAILABLE.
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Deck/Cargo
Issued 22 April 1992 Resolved
CARGO PUMPROOM FANS STILL INOP (FROM 31AUG91). VSL MAY NOT CARRY ANY CRUDE OIL OR GRADES B,C,D CARGOS IN US WATERS UNTIL CLEARED.
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Accommodation/Occupational Safety
Issued 31 August 1991 Resolved
MSO INSPECTORS ON BOARD TRACED THE SANITATION LINES AND WERE UNABLE TO LOCATE ANY HOLDING OR TREATMENT TANK ON BOARD THE VESSEL. WHEN QUESTIONED ABOUT THE MSD SEVERAL OF THE CREW INCLUDING THE CAPTAIN STATED THAT THEY DIDN'T HAVE ONE.
Condition: Unknown
Due 28 July 1993
Resolved 28 July 1993
Documentation
Issued 31 August 1991 Resolved
PROCEDURES FOR TOPPING OFF TANKS FOR TAKING ON BUNKERS WAS NOT MENTIONED ONTHE OIL TRANSFER PROCEDURES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 August 1991
Resolved 3 September 1991
Accommodation/Occupational Safety
Issued 31 August 1991 Resolved
INSTALL PROPER MARINE SANITATION DEVICE IN ACCORDANCE WITH 33 CFR 159.7(c) (1). UNTIL THIS REQUIREMENT IS SATISFIED AT NEXT U.S. PORT, ALL SEWAGE OVERBOARD VALVES MUST BE LOCKED CLOSED WHILE OPERATING IN U.S. WATERS.
Condition: Unknown
Due 31 August 1991
Resolved 31 August 1991
Deck/Cargo
Issued 31 August 1991 Resolved
INSTALL BLANK FLANGES ON ALL CARGO HOSES ON DECK IN ACCORDANCE WITH 33 CFR 155.805 PRIOR TO ARRIVAL AT ANY U.S. PORT.
Condition: Unknown
Due 31 August 1991
Resolved 31 August 1991
Deck/Cargo
Issued 31 August 1991 Resolved
PROVE PROPER OPERATION OF GUAGES IN AFT PUMPROOM AND CARGO CONTROL ROOM AT NEXT U.S. PORT.
Condition: Unknown
Due 31 August 1991
Resolved 31 August 1991
Deck/Cargo
Issued 31 August 1991 Resolved
PROVE PROPER OPERATION OF AFT PUMPROOM SUPPLY AND EXHAUST FANS AT NEXT U.S.PORT.
Condition: Unknown
Due 31 August 1991
Resolved 31 August 1991
Deck/Cargo
Issued 31 August 1991 Resolved
VESSEL IS LIMITED TO CARGO PUMP OPERATIONS AT A PRESSURE OF 5KG/CM2 UNTIL ALL CARGO PIPING AND HOSES HAVE BEEN HYDROSTATICALLY TESTED TO 9 KG/CM2 PRIOR TO ARRIVAL NEXT U.S. PORT.
Condition: Unknown
Due 31 August 1991
Resolved 31 August 1991
Construction/Loadline
Issued 31 August 1991 Resolved
AFT PUMPROOM AND BILGES ARE TO BE CLEANED AFTER ALL CARGO AND HYDRAULIC LEAKS ARE STOPPED AND PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 31 August 1991
Resolved 31 August 1991
Construction/Loadline
Issued 31 August 1991 Resolved
MAKE AVAILABLE A BALLAST TANK IN THE MIDBODY SECTION. TANK MUST BE CERTIFIED GAS FREE BY A CERTIFIED MARINE CHEMIST.
Condition: Unknown
Due 31 August 1991
Resolved 31 August 1991
Deck/Cargo
Issued 27 June 1990 Resolved
CONDUCT HYDROSTATIC TEST OF VESSEL'S CARGO PIPING PRIOR TO TRANSFER OF PRODUCTS IN NEXT U.S. PORT. PIPING IS TO BE TESTED TO 1 1/2 TIMES SYSTEM MAWP.
Condition: Unknown
Due 27 June 1990
Resolved 27 June 1990

Ownership record