GEMINI EXPLORER is a 1973 freight ship. The Coast Guard has recorded 16 inspections since 1984, most recently in December 1997, along with 10 deficiencies.
Records from 1984 to 1997. Most recent: inspection, 1 December 1997.
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for GEMINI EXPLORER, retrieved 18 September 2026. mauryrecords.com/v/psix-226613.html
Documentation record
Tonnage as PSIX records it11023 - Simplified, Net Ton 34173 - Dead Weight, Ton 20400 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
1 December 1997Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 410727
26 June 1996Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 392443
14 March 1995Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 376059
6 September 1994Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 655986
2 September 1994Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 370078
25 April 1994Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 366310
22 March 1993Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 506777
21 February 1993Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 356539
8 April 1992Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 349990
22 June 1989Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 331008
1 September 1988Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 531933
11 January 1988Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 320648
5 May 1987Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 522605
9 November 1986Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 312589
25 April 1985Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 301576
26 November 1984Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 488298
THE 5 VOLT POWER SUPPLY WAS AT 4.8 VOLTS, IT SHOULD BE AT 5.2 VOLTS. RADIOHOLLAND RESET THE VOLTAGE TO COMPUTER PCB AND MADE ALINGMENT OF JOY STICK AND OFF/CENTER ADJUSTMENT. COTP CORPUS CHRISTI GRANTED DEVIATION TO ENTER PORT WITH INOPERABALE ARPA, LETTER DATED NOVEMBER 26, 1997.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Navigation
Issued 26 June 1996Resolved
NO MANEUVERING FACT SHEET WAS POSTED ON THE BRIDGE.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Construction/Loadline
Issued 26 June 1996Resolved
THE LOADLINE WAS RUSTED AND NOT PLAINLY VISABLE
Condition: Unknown
Due 7 July 1996
Resolved 8 July 1996
Accommodation/Occupational Safety
Issued 2 September 1994Resolved
VESSEL WAS USING THE IMPROPER CHEMICALS IN THE TYPE II MSD. CHEMICALS_x001C_ USED WERE FOR SWIMMING POOLS. WARNING STATEMENT ON THE BOTTLE ADVISED THAT THEY WERE HARMFUL TO THE ENVIRONMENT.
Condition: Unknown
Due 8 September 1994
Resolved 7 September 1994
Navigation
Issued 21 February 1993Resolved
VESSEL DID NOT HAVE CURRENT COAST PILOT.
Condition: Unknown
Due 10 March 1995
Resolved 10 March 1995
Navigation
Issued 21 February 1993Resolved
VESSEL DID NOT HAVE CURRENT LIGHT LIST ON BOARD.
Condition: Unknown
Due 10 March 1995
Resolved 10 March 1995
Navigation
Issued 8 April 1992Resolved
VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ON BOARD.
Condition: Unknown
Due 12 April 1992
Resolved 14 April 1992
Navigation
Issued 8 April 1992Resolved
VESSELS B.A. CHARTS 899 AND 1082 WERE NOT CORRECTED TO DATE.
Condition: Unknown
Due 12 April 1992
Resolved 14 April 1992
Navigation
Issued 8 April 1992Resolved
VESSELS B.A. LIST OF LIGHTS VOL. G WAS NOT CORRECTED TO DATE.
Condition: Unknown
Due 12 April 1992
Resolved 14 April 1992
Documentation
Issued 22 June 1989Resolved
OIL TRANSFER PROCEDURES MISSING SEVERAL ITEMS THAT ARE REQUIRED BY 33CFR155.750(A)
Condition: Unknown
Due 22 June 1989
Resolved 22 June 1989
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.