← All vessels
TAXIARCHIS
Freight Ship · General Dry Cargo Ship class · Built 1970s · USCG East District (CGD-E) · Other hulls named TAXIARCHIS
TAXIARCHIS is a 1974 freight ship. The Coast Guard has recorded 39 inspections since 1984, most recently in March 1995, along with 141 deficiencies and 4 operational controls.
Records from 1984 to 1995. Most recent: operational control imposed, 23 March 1995.
- Built
- 1974
- Last inspected
- 23 March 1995
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 141 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7353602 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
J8K89
226617
Flag
CYPRUS
—
Maury page id
psix-226617
Inspections, by type
…with no type recorded37
Years with a record
12 calendar years (1984–1995)
The 39 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it3177 - Convention (Subpart B), Net Ton
2881 - Regulatory (Subpart C or D), Net Ton
8382 - Dead Weight, Ton
5295 - Convention (Subpart B), Gross Ton
4551 - Regulatory (Subpart C or D), Gross Ton
2881 - Regulatory (Subpart C or D), Net Ton
8382 - Dead Weight, Ton
5295 - Convention (Subpart B), Gross Ton
4551 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 39
23 March 1995
Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 376583
24 January 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 374361
15 July 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1145273
27 June 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 368049
15 June 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 697470
18 May 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 366921
1 December 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 362864
21 July 1993
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 667535
20 June 1993
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 74959
21 March 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 356983
11 January 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 667536
10 December 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 355038
23 November 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 652438
29 October 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 354042
10 October 1992
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 355012
20 July 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 352085
28 April 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 667534
15 April 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 114652
15 April 1992
Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1261153
14 April 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 117940
31 March 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 469131
31 March 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 477873
28 January 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 348471
15 November 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 347212
18 October 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 667537
28 September 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1245296
19 September 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 345891
10 September 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 339239
29 November 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 525506
12 June 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 330877
9 November 1988
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 326975
23 October 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 319237
14 September 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 318401
24 December 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 313433
20 July 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 310213
21 March 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 476953
9 September 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 304060
26 October 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 475616
21 May 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 296431
Deficiency record · 141
Engineering
Issued 23 March 1995
Resolved
Test bunker transfer piping to 1 1/2 the maximum allowable working pressure(MAWP). Minimum MAWP is 150 psi. Minimum test pressure is 225 psi. _x001C_ 33 CFR 156.170(c)(2) To be completed prior to transfer oprations in a U.S.port.
Navigation
Issued 23 March 1995
Resolved
Provide a Coast Pilot [name withheld], Tide Table, Tidal Current Table and Notice to Mariners from 37/94 to present. 33 CFR 164.30(a)(2)&(3)
Engineering
Issued 23 March 1995
Resolved
Install a "Discharge of Oil Prohibited" placard of a least 5" X 8" made of durable material in a conspicuous place in the machinery space or at the bilge and ballast pump control station. 33 CFR 155.450(a)
Construction/Loadline
Issued 23 March 1995
Resolved
Paint draft marks in a contrasting color to the hull. 46 CFR 97.40-10(f) To be completed prior to returning to a U.S. port.
Accommodation/Occupational Safety
Issued 23 March 1995
Resolved
Repair guard rails starboard aft corner of forecastle._x001C_ ICLL 1966 ANNEX I/25(4)
Documentation
Issued 23 March 1995
Resolved
Provide a International Tonnage Certificate. ITC 1969 Artical 7.
Lifesaving
Issued 23 March 1995
Resolved
Mount all portable fire extinguishers in proper brackets. (Extinguishers presently tied in place with a line) SOLAS 60 II/57(e)
Lifesaving
Issued 23 March 1995
Resolved
Mount in a bracket the semi-portable fire extinguisher located inside the port engine room access door. SOLAS 60 II/57(e)
Construction/Loadline
Issued 23 March 1995
Resolved
Gouge and weld missing weld on overhead of forecastle compartment in the_x001C_ bow area. SOLAS 60 II/17(a)
Electrical
Issued 23 March 1995
Resolved
Properly install or remove wiring between 110 volt power panel box and cover. SOLAS 60 II/27(a) (vi)
Fire Fighting
Issued 23 March 1995
Resolved
Service fixed fire fighting system for machinery space and cargo hold. SOLAS 60 II/66
Construction/Loadline
Issued 23 March 1995
Resolved
Make the guaging reports and shell expansion plans available to the Officerin Charge, Marine Inspection for review. SOLAS 60 I/10
Electrical
Issued 23 March 1995
Resolved
Remove the electrical cable in the forward bulkhead and weld the hole closed in way of the upper level engine room, portside, behind main engine dirty oil tank._x001C_ SOLAS 60 II/54(b).
Construction/Loadline
Issued 23 March 1995
Resolved
Crop and renew wasted bulkhead between crews head and the engine room, across from the hospital space. SOLAS 60 II/54(b)
Construction/Loadline
Issued 23 March 1995
Resolved
Permanently close the hole in the bulkhead above starboard main deck engineroom access door. Hole is approximentaly 3 inches by 6 inches. SOLAS 60 II/54(b)
Construction/Loadline
Issued 23 March 1995
Resolved
Remove the BV markings from the loadline and permanently mark with the new load line assigning authority marks. ICLL 1966 ANNEX I/7
Documentation
Issued 23 March 1995
Resolved
Permanently exhibit damage control plans. SOLAS 60 II/20
Lifesaving
Issued 23 March 1995
Resolved
Repair/replace brake pads on all mooring winches, boom winches and anchor windlasses. SOLAS 74 II-1/26.1
Navigation
Issued 23 March 1995
Resolved
Provide a block diagram on the bridge that matches the one posted in the engine room. Provide operating instructions on brige and steering gear room for all modes of operation in a language understood by the crew. _x001C_ 33 CFR 164.35(k)
Electrical
Issued 23 March 1995
Resolved
Make repairs to wiring in port forward corner of CO2 room so that there is no bare wiring exposed. SOLAS 60 II/27(a)(1)
Lifesaving
Issued 23 March 1995
Resolved
Clean oil from deck in steering gear compartment. SOLAS 74 II-1/26.1
Navigation
Issued 23 March 1995
Resolved
Prove proper operation of steering gear in the non-follow up mode. SOLAS 60 II/29_x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 23 March 1995
Resolved
Make repairs to the #3 cargo hatch coaming to the satisfaction of the flag administration. Hole located approximately 2 feet inboard from the aft starboard corner. SOLAS 60 II/17(b)
Construction/Loadline
Issued 23 March 1995
Resolved
Install a means of closing the air pipe located across from the starboard anchor windlass. SOLAS 60 II/17(b)
Lifesaving
Issued 23 March 1995
Resolved
Install self-activation smoke signals for bridge life buoys so that they are capable of being quickly released without becoming hung up and fall freely. SOLAS 60 III/21(g)
Accommodation/Occupational Safety
Issued 23 March 1995
Resolved
Repair wasted platforms on forward mast for cargo boom controls. ICLL_x001C_ 1966 ANNEX I/25(4)
Lifesaving
Issued 23 March 1995
Resolved
Place all high pressure gas cylinders in proper brackets and place wood between deck and bottom of cylinders. 33 CFR 147.60(b)
Construction/Loadline
Issued 23 March 1995
Resolved
Remove welding cable from bottom of port engine room access door on main deck and repair door sill so door fits tightly. SOLAS 60 II/54(b)
Fire Fighting
Issued 23 March 1995
Resolved
Provide securing device for port main deck engine room access door that canbe opened from both sides.
Construction/Loadline
Issued 23 March 1995
Resolved
Weld the hole closed in bulkhead forward of aft port main deck engine room access door. SOLAS 60 II/54(b)
Construction/Loadline
Issued 23 March 1995
Resolved
Permanently close the opening around the hot water piping coming from main machinery space, located across from chief cooks cabin. SOLAS 60 II/54(b)
Fire Fighting
Issued 23 March 1995
Resolved
Provide spare portable fire extinguishers to the satisfaction of the Flag Administration. SOLAS 60 II/57(b)
Fire Fighting
Issued 23 March 1995
Resolved
Prove proper operation of fire dampners for the engine room ventilation. Damper controls are located on captains deck. SOLAS 60 II/69(a)
Fire Fighting
Issued 23 March 1995
Resolved
Prove proper operation of main fire pumps. SOLAS 60 II/65(b)
Documentation
Issued 23 March 1995
Resolved
Provide a safe manning certificate. SOLAS 74 V/13_x001C_
Lifesaving
Issued 23 March 1995
Resolved
Clean oil for starboard generator. SOLAS 74 II-1/26.1
Lifesaving
Issued 23 March 1995
Resolved
Clean oil from deck plates, lower level starboard side of main engine. SOLAS 74 II-I/26.1
Fire Fighting
Issued 23 March 1995
Resolved
Provide two breathing apparatus with interchangeable spare charges. The number of spare charges shall be to the satisfaction of the flag administration. SOLAS 74 II-2/17.3
Lifesaving
Issued 23 March 1995
Resolved
Provide a 406 Mhz EPIRB. SOLAS 74 IV/7.6.1
Lifesaving
Issued 23 March 1995
Resolved
Conduct a fire and abandon ship drill in accordance with vessels muster list and vessel's SOLAS training manual. SOLAS 74 V/13
Lifesaving
Issued 23 March 1995
Resolved
Prove proper operation of general alarm system. SOLAS 74 II/50
Engineering
Issued 23 March 1995
Resolved
Prove proper operation of oily water separator 15 ppm alarm. MARPOL 74/78 ANNEX I/16
Engineering
Issued 23 March 1995
Resolved
Install metal plug in place of wood plug on discharge side of oily water separator. SOLAS 60 II/14
Lifesaving
Issued 24 January 1995
Resolved
Clean excessive oil from engine room bilges. SOLAS 60 II/34
Fire Fighting
Issued 24 January 1995
Resolved
Repair flex hose loops at CO2 bottles for cargo and machinery space fixed CO2 system. Provide report from class society that system has been properlyserviced and is in operational condition. SOLAS 60 II/65
Construction/Loadline
Issued 15 July 1994
Resolved
REPLACE GASKET FITTING AROUND BATTERY ROOM DOOR AND REPLACE SEVEN MISSING_x001C_ DOGS FROM DOOR. SOLAS, CHAPTER I, REG XI.
Lifesaving
Issued 15 July 1994
Resolved
PROVIDE THIS OFFICE WITH A CLASS REPORT AS TO THE SEAWORTHINESS OF THE PORT AND STARBOARD LIFE BOAT. SOLAS, CHAPTER III, REG 19._x001C_
Lifesaving
Issued 15 July 1994
Resolved
RENEW PORT AND STARBOARD EMBARKATION LIGHT BULBS ON MAST. SOLAS, CHAPTER I, REG XI._x001C_ _x001C_ ,_x001C_
Fire Fighting
Issued 15 July 1994
Resolved
INSTALL FIRE NOZZLE AND SPANNER WRENCH AT 02 DECK AFT FIRE STATION. SOLAS,CHAPTER II-2, REG 4._x001C_
Construction/Loadline
Issued 15 July 1994
Resolved
RENEW WASTED AND BROKEN MAST GUIDE WIRE ANCHOR PLATES. SOLAS, CHAPTER I,_x001C_ REG XI.
Lifesaving
Issued 15 July 1994
Resolved
RENEW BOUYANT APPARATUS AT AFT LIFE BOAT DECK, PORTSIDE. SOLAS, CHAPTER III, REG 30_x001C_
Construction/Loadline
Issued 15 July 1994
Resolved
RENEW WEATHER TIGHT DOOR KNIFE EDGE FOR AIR CONDITIONING MACHINERY ROOM ON_x001C_01 DECK. SOLAS, CHAPTER I, REG XI.
Engineering
Issued 15 July 1994
Resolved
REPAIR RAW WATER COOLING PUMPS FOR MAIN ENGINE. SOLAS, CHAPTER II-I, REG_x001C_ XXVI.
Engineering
Issued 15 July 1994
Resolved
REPAIR OILY WATER SEPARATOR. 33 CFR 155.380.
Engineering
Issued 15 July 1994
Resolved
REPAIR PORT GENERATOR EXCESSIVE COOLING WATER AND LUBE OIL LEAKS. SOLAS,_x001C_ CHAPTER II-I, REG XXVI.
Engineering
Issued 15 July 1994
Resolved
SERVICE MAIN ENGINE LUBE OIL PUMP. SOLAS, CHAPTER II-I, REG XXVI.
Construction/Loadline
Issued 15 July 1994
Resolved
MAKE FORECASTLE WATER TIGHT. SOLAS, CHAPTER I, REG XI.
Construction/Loadline
Issued 15 July 1994
Resolved
RENEW BRACKET INSIDE FORECASTLE UNDER BULL NOSE AT INTERSECTION OF BRACKET_x001C_AND MAIN DECK. SOLAS, CHAPTER I, REG XI.
Construction/Loadline
Issued 15 July 1994
Resolved
RENEW APPROXIMATELY TWO FOOT OF WELD PORT SIDE AFT OF BULL NOSE AT THE_x001C_ INTERSECTION OF NO. 1 DECK BEAM AND DECK. SOLAS, CHAPTER I, REG XI.
Construction/Loadline
Issued 15 July 1994
Resolved
REPAIR COMBING,STARBOARD SIDE CARGO HOLD, FORE AND AFT. SOLAS, CHAPTER I,_x001C_REG XI.
Construction/Loadline
Issued 15 July 1994
Resolved
REPAIR PORT AND STARBOARD SIDE CARGO HOLD FRAMES SUPPORTING COMBING, FORE _x001C_AND AFT. SOLAS, CHAPTER I, REG XI.
Navigation
Issued 15 July 1994
Resolved
REPAIR ECHO DEPTH SOUNDER. 33 CFR 164.35(h).
Navigation
Issued 15 July 1994
Resolved
REPAIR GYROCOMPASS. 33 CFR 164.35(d).
Construction/Loadline
Issued 15 July 1994
Resolved
RENEW ALL UNSERVICABLE DECK PLATING IN ENGINE ROOM.
Engineering
Issued 15 July 1994
Resolved
REPAIR OR REPLACE WASTED VENTS AND FLAME SCREENS AT NO.2 AND NO.3 FUEL OIL_x001C_TANK VENTS. 46 CFR 56.50-85.
Accommodation/Occupational Safety
Issued 15 July 1994
Resolved
REPAIR NO.1 AND NO.2 FRESH WATER SERVICE PUMP.
Accommodation/Occupational Safety
Issued 15 July 1994
Resolved
PROVIDE HOT AND COLD RUNNING WATER FOR ALL CREW MEMBERS.
Engineering
Issued 15 July 1994
Resolved
REPAIR MAIN ENGINE AND PROVIDE A COPY OF THE CLASS REPORT TO THIS OFFICE._x001C_ SOLAS, CHAPTER II-I, REG 46.
Engineering
Issued 15 July 1994
Resolved
REPLACE SAFETY GUARDS FOR ALL BELT DRIVEN EQUIPMENT.
Lifesaving
Issued 15 July 1994
Resolved
REPLACE WEAK LINK ON THE STARBOARD LIFE RAFT. SOLAS, CHAPTER III, REG 38.
Deck/Cargo
Issued 15 July 1994
Resolved
REPAIR PATCHED AREA ON NO.3 BOOM CABLE WINCH WHERE LEAKING. SOLAS, CHAPTERI, REG XI._x001C_ _x001C_
Construction/Loadline
Issued 15 July 1994
Resolved
REPAIR OR REPLACE WASTED VENT AND REPLACE CHECK VALVE AT THE FOREPEAK TANK_x001C_VENT. SOLAS, CHAPTER I, REG XI.
Construction/Loadline
Issued 15 July 1994
Resolved
REPAIR OR REPLACE WASTED VENT AND REPLACE CHECK VALVE AT NO.3 BALLAST TANK VENT. SOLAS, CHAPTER I, REG XI.
Lifesaving
Issued 15 July 1994
Resolved
REPLACE REFLECTIVE TAPE, AND ATTACHING GRAB LINE WITH APPROVED NYLON WEBBING ON SIX LIFE RINGS. SOLAS, CHAPTER III, REG 30.
Construction/Loadline
Issued 15 July 1994
Resolved
REPAIR WASTED PLATFORM FRAMES AT NO.1 AND NO.2 BOOM. SOLAS, CHAPTER I,_x001C_ REG XI.
Engineering
Issued 27 June 1994
Resolved
Install proper piping on discharge side of oily water seperator. Remove oil from #3 port ballast tank. Install valve bonnet in engine room for #3 port ballast tank.
Navigation
Issued 27 June 1994
Resolved
A VIOLATION OF 33 C.F.R. 164.33(a)(1)(ii) IN THAT CHARTS # 12221, AND #12222 WERE NOT CORRECTED TO LATEST NOTICE TO MARINERS WHICH WERE READILY AVAILABLE AND EASY TO OBTAIN.
Navigation
Issued 27 June 1994
Resolved
REPAIR GYRO COMPASS AND PROVE PROPER OPERATION OF SAME TO CAPTAIN OF THE PORT HAMPTON ROADS PRIOR TO DEPARTURE FROM PORT.
Construction/Loadline
Issued 18 May 1994
Resolved
NUMBER 2 STBD BALLAST TANK TAKING ON WATER.
Deck/Cargo
Issued 18 May 1994
Resolved
CARGO HANDLING GEAR SHOWS SEVERE SIGNS OF WASTAGE & WEAR.
Construction/Loadline
Issued 18 May 1994
Resolved
FREE COMMUNICATION BETWEEN FOCSILE & NUMBER 1 HOLD WHICH IS ALLOWING WATER_x001C_INTO THE NUMBER 1 HOLD.
Construction/Loadline
Issued 18 May 1994
Resolved
FREE COMMUNICATION FROM PAINT LOCKER ON MAIN DECK INTO NUMBER 3 HOLD.
Accommodation/Occupational Safety
Issued 18 May 1994
Resolved
ROACHES THROUGHOUT GALLEY, MESSDECK & LIVING SPACES. ILO 147 REG. 2-F-2
Fire Fighting
Issued 18 May 1994
Resolved
FIREMAIN PIPING ON MAIN DECK HOLED IN THREE LOCATIONS._x001C_ SOLAS CHAPTER II-2, REG. 4 6
Accommodation/Occupational Safety
Issued 18 May 1994
Resolved
VSL'S PORT GANGWAY SEVERELY WASTED & UNSAFE.
Lifesaving
Issued 18 May 1994
Resolved
VSL HAS 16 COMPRESSED GAS CYLINDERS ON THE OPEN DECK NOT PROPERLY STORED INA RACK & NOT PROPERLY CAPPED. 33 CFR 160.109 VIA 46 CFR 147.1(b)
Accommodation/Occupational Safety
Issued 18 May 1994
Resolved
MANY CREW ACCOMADATIONS LEAKING WATER THROUGH OVERHEAD ONTO SLEEPING AREAS_x001C_& DECKS. ILO 147 REG. 2-D-1
Documentation
Issued 18 May 1994
Resolved
VSL'S INTERNATIONAL OIL POLLUTION PREVENTION (IOPP) CERTIFICATE MISSING_x001C_ ITS FORM A SUPPLEMENT.
Lifesaving
Issued 18 May 1994
Resolved
VSL'S PORT & STBD LIFEBOATS MISSING THEIR SEA ANCHORS._x001C_ SOLAS CHAPTER III, REG. 41 8.6
Navigation
Issued 18 May 1994
Resolved
LARGE SCALE CHART OF SAN JUAN HARBOR NOT CURRENTLY CORRECTED.
Navigation
Issued 18 May 1994
Resolved
PRE-ARRIVAL TESTS REQUIRED NOT LOGGED IN SHIP'S LOGBOOK.
Navigation
Issued 18 May 1994
Resolved
CONTINUOUS RECORDER FOR ECHO DEPTH SOUNDER INOPERABLE.
Documentation
Issued 18 May 1994
Resolved
COMPLETED PAGES OF OIL RECORD BOOK NOT SIGNED BY THE MASTER.
Documentation
Issued 18 May 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 18 May 1994
Resolved
STARBOARD LIFERAFT ANNUAL INSPECTION EXPIRED. _x001C_ SOLAS CHAPTER III, REG. 19 8.1
Lifesaving
Issued 18 May 1994
Resolved
PORT LIFEBOAT NOT EXERCISED SINCE NEW CREW CAME ABOARD._x001C_ SOLAS CHAPTER III, REG 18 3.4
Lifesaving
Issued 18 May 1994
Resolved
STARBOARD LIFEBOAT NOT EXERCISED SINCE NEW CREW CAME ABOARD._x001C_ SOLAS CHAPTER III, REG. 18 3.4
Construction/Loadline
Issued 18 May 1994
Resolved
ENGINEROOM MAIN BILGE PUMP INOPERABLE. SOLAS CHAPTER II-I, REG. 21 1.1
Fire Fighting
Issued 18 May 1994
Resolved
VSL'S EMERGENCY FIRE PUMP IS REMOVED. SOLAS CHAPTER II-2, REG. 4 3.1.2
Construction/Loadline
Issued 18 May 1994
Resolved
WATERTIGHT DOORS THROUGHOUT SHIP NOT WATERTIGHT._x001C_ SOLAS CHAPTER II-1, REG. 14 1
Fire Fighting
Issued 18 May 1994
Resolved
FIRE DRILL NOT CONDUCTED SINCE NEW CREW CAME ABOARD._x001C_ SOLAS CHAPTER III, REG. 18 3.1
Construction/Loadline
Issued 18 May 1994
Resolved
MANHOLE COVERS FOR BALLAST TANKS ON MAIN DECK WELDED SHUT, NUTS & BOLTS MISSING, & CONCRETED POURED OVER.
Electrical
Issued 18 May 1994
Resolved
ELECTRIC LIGHTS THROUGHOUT VSL MISSING GLOBES & GUARDS._x001C_ ILO 147 REG. 2-C-5
Electrical
Issued 18 May 1994
Resolved
GALLEY ELECTRICAL PANEL FULLY EXPOSED. ILO 147 REG. 2-C-5
Fire Fighting
Issued 18 May 1994
Resolved
ALL FIRE STATIONS MISSING HOSES & EQUIPMENT. _x001C_ SOLAS CHAPTER II-2, REG. 4-7.1
Fire Fighting
Issued 18 May 1994
Resolved
NOZZLES FOR THE FIRE HOSES NOT OF AN APPROVED DUAL PURPOSE TYPE._x001C_ SOLAS CHAPTER II-2, REG. 4-8.8.4
Fire Fighting
Issued 18 May 1994
Resolved
VSL HAS NO INTERNATIONAL SHORE CONNECTION. _x001C_ SOLAS CHAPTER II-2, REG. 19
Engineering
Issued 18 May 1994
Resolved
VSL'S OILY WATER SEPARATOR INOPERABLE.
Engineering
Issued 18 May 1994
Resolved
STARBOARD DIESEL GENERATOR LEAKING DIESEL FUEL FROM THE NUMBER 6 INJECTOR.
Engineering
Issued 18 May 1994
Resolved
PORT DIESEL GENERATOR LEAKING DIESEL FUEL FROM THE NUMBER 6 INJECTOR.
Construction/Loadline
Issued 18 May 1994
Resolved
VSL HAS EXCESSIVE LUBE OIL/DIESEL FUEL THROUGHOUT ENGINEROOM & BILGES.
Accommodation/Occupational Safety
Issued 18 May 1994
Resolved
VSL'S TYPE III MARINE SANITATION DEVICE TANK CAPACITY INADEQUATE FOR_x001C_ NUMBER OF CREWMEMBERS.
Documentation
Issued 21 March 1993
Resolved
THE VESSEL WAS IN VIOLATION OF SOLAS REGULATION 12 IN THAT THE VESSEL DID NOT HAVE ON BOARD, A VALID SAFETY RADIO TELEGRAPHY CERTIFICATE.
Construction/Loadline
Issued 10 December 1992
Resolved
THE VESSEL DID NOT HAVE A PROPERLY OPERATING OILY WATER SEPARATOR.
Fire Fighting
Issued 29 October 1992
Resolved
EMERGENCY FIRE PUMP NOT OPERABLE
Fire Fighting
Issued 10 October 1992
Resolved
VSL'S FIRE HOSES WERE NOT ON STATION A VIOLATION OF SOLAS CH. 2-2 PART A REG 4.7.
Documentation
Issued 10 October 1992
Resolved
FIRE PLAN WAS NOT POSTED ON THE WEATHERDECK A VIOLATION OF SOLAS CH. 2-2 PART A REG 20.
Fire Fighting
Issued 10 October 1992
Resolved
NOZZLES FOR THE FIRE HOSES WERE NOT OF THE APPROVED DUAL PURPOSE TYPE A VIOLATION OF SOALS CH.2-2 PART A REG. 4.8.
Documentation
Issued 10 October 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering
Issued 10 October 1992
Resolved
VSL COULD NOT PROVE PROPER OPERATION OF THE OILY WATER SEPERATOR.
Navigation
Issued 10 October 1992
Resolved
VSL DID NOT HAVE A CHART FOR THE AREA TRANSITED.
Fire Fighting
Issued 10 October 1992
Resolved
VESSEL'S EMER. FIRE PUMP WAS NOT OPERATING PROPERLY (NO SUCTION AT 4.5M DRAFT) A VIOLATION OF SOLAS CH. 2-2 PART C REG 4.3.
Fire Fighting
Issued 10 October 1992
Resolved
VSL DID NOT HAVE AN INTERNATIONAL SHORE CONNECTION A VIOLATION OF SOLAS CH.2-2 PART A REG 19.
Documentation
Issued 10 October 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation
Issued 20 July 1992
Resolved
33 CFR 164.35(A)(1) CHART 11370 NOT ON BOARD.
Navigation
Issued 20 July 1992
Resolved
33 CFR 164.35(G) VESSEL DOES NOT HAVE A MANUVERING FACT SHEET.
Navigation
Issued 20 July 1992
Resolved
33 CFR 164.35(A)(1) THE FOLLOWING CHARTS ARE NOT UPDATED: 11363,11364,11361,11368.
Navigation
Issued 14 April 1992
Resolved
SOLENOID FOR #2 STEERING PUMP STUCK OPEN, ALLOWING STEERING RAM TO TRAVEL TO THE FULL RIGHT POSITION.
Construction/Loadline
Issued 28 September 1991
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPERATOR AND ALARM PRIOR TO RETURN TOA U.S. PORT.
Deck/Cargo
Issued 19 September 1991
Resolved
Vessel had no fixed containment or enclosed deck area under or around the port or starboard fuel oil manifold_x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 19 September 1991
Resolved
Vessel did not have Pollution Placards posted in the engine room._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 19 September 1991
Resolved
Vessel failed to have an operable Oil Water Separator.
Accommodation/Occupational Safety
Issued 19 September 1991
Resolved
Vessel failed to have certification label affixed to MSD.
Documentation
Issued 12 June 1989
Resolved
EXPIRED SOLAS SAFETY RADIOTELEGRAPHY CERTIFICATE. SOLAS REGULATION 12 CH. 1
Navigation
Issued 12 June 1989
Resolved
VESSEL'S DEVIATION TABLE OUTDATED 33 CFR 164.35(C) 33USC1232
Documentation
Issued 12 June 1989
Resolved
POLLUTION PLACARD NOT PROPERLY POSTED 33 CFR 155.450(A) 33 USC 1908(B)(1)
Documentation
Issued 12 June 1989
Resolved
VESSEL'S OIL TRANSFER PROCEDURES WERE INCOMPLETE. 33 CFR 155.750 33 CFR 155.720 33 USC 1321(J)(2)
Navigation
Issued 9 November 1988
Resolved
VESSEL OVER 1600 GROSS TONS ENTERED US PORT, SAVANNAH, GA. WITHOUT A CURRENT/CORRECTED COPY OF COAST GUARD LIGHT LIST VOLUME 111. A VIOLATION OF 33 CFR 164.33(2)(II)
Navigation
Issued 9 November 1988
Resolved
VESSEL OVER 1600 GROSS TONS ENTERED US PORT, SAVANNAH, GA. WITHOUT A CURRENT/CORRECTED COPY OF THE US COAST PILOT VOLUME 4. A VIOLATION OF 33 CFR 164.33(2)(I)
Navigation
Issued 14 September 1987
Resolved
33CFR164.33(A)(1)(II) THE VESSEL'S CHARTS WERE NOT CURRENT OR CORRECTED.
Documentation
Issued 14 September 1987
Resolved
33CFR155.720 THE VESSEL'S OIL TRANSFER PROCEDURES WERE INCOMPLETE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.