MAURY USCG vessel records Sign in
← All vessels

TAXIARCHIS

TAXIARCHIS is a 1974 freight ship. The Coast Guard has recorded 39 inspections since 1984, most recently in March 1995, along with 141 deficiencies and 4 operational controls.

Records from 1984 to 1995. Most recent: operational control imposed, 23 March 1995.

Built
1974
Last inspected
23 March 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7353602 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226617
Flag
CYPRUS
—
Maury page id
psix-226617

Inspections, by type

…with no type recorded37
Years with a record 12 calendar years (1984–1995)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3177 - Convention (Subpart B), Net Ton
2881 - Regulatory (Subpart C or D), Net Ton
8382 - Dead Weight, Ton
5295 - Convention (Subpart B), Gross Ton
4551 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 39

23 March 1995 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 376583
24 January 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 374361
15 July 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1145273
27 June 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 368049
15 June 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 697470
18 May 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 366921
1 December 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 362864
21 July 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 667535
20 June 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 74959
21 March 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 356983
11 January 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 667536
10 December 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 355038
23 November 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 652438
29 October 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 354042
10 October 1992 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 355012
20 July 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 352085
28 April 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 667534
15 April 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 114652
15 April 1992 Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1261153
14 April 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 117940
31 March 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 469131
31 March 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 477873
28 January 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 348471
15 November 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 347212
18 October 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 667537
28 September 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1245296
19 September 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 345891
10 September 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 339239
29 November 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 525506
12 June 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 330877
9 November 1988 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 326975
23 October 1987 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 319237
14 September 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 318401
24 December 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 313433
20 July 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 310213
21 March 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 476953
9 September 1985 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 304060
26 October 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 475616
21 May 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 296431

Deficiency record · 141

Engineering
Issued 23 March 1995 Resolved
Test bunker transfer piping to 1 1/2 the maximum allowable working pressure(MAWP). Minimum MAWP is 150 psi. Minimum test pressure is 225 psi. _x001C_ 33 CFR 156.170(c)(2) To be completed prior to transfer oprations in a U.S.port.
Condition: Unknown
Due 29 March 1995
Resolved 10 January 2002
Resolution: Administratively closed due to age of deficiencies.
Navigation
Issued 23 March 1995 Resolved
Provide a Coast Pilot [name withheld], Tide Table, Tidal Current Table and Notice to Mariners from 37/94 to present. 33 CFR 164.30(a)(2)&(3)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Engineering
Issued 23 March 1995 Resolved
Install a "Discharge of Oil Prohibited" placard of a least 5" X 8" made of durable material in a conspicuous place in the machinery space or at the bilge and ballast pump control station. 33 CFR 155.450(a)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 23 March 1995 Resolved
Paint draft marks in a contrasting color to the hull. 46 CFR 97.40-10(f) To be completed prior to returning to a U.S. port.
Condition: Unknown
Due 29 March 1995
Resolved 10 January 2002
Resolution: Administratively closed due to age of deficiencies.
Accommodation/Occupational Safety
Issued 23 March 1995 Resolved
Repair guard rails starboard aft corner of forecastle._x001C_ ICLL 1966 ANNEX I/25(4)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Documentation
Issued 23 March 1995 Resolved
Provide a International Tonnage Certificate. ITC 1969 Artical 7.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 23 March 1995 Resolved
Mount all portable fire extinguishers in proper brackets. (Extinguishers presently tied in place with a line) SOLAS 60 II/57(e)
Condition: Unknown
Due 29 April 1995
Resolved 10 January 2002
Resolution: Administratively closed due to age of deficiencies.
Lifesaving
Issued 23 March 1995 Resolved
Mount in a bracket the semi-portable fire extinguisher located inside the port engine room access door. SOLAS 60 II/57(e)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 23 March 1995 Resolved
Gouge and weld missing weld on overhead of forecastle compartment in the_x001C_ bow area. SOLAS 60 II/17(a)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 23 March 1995 Resolved
Properly install or remove wiring between 110 volt power panel box and cover. SOLAS 60 II/27(a) (vi)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Fire Fighting
Issued 23 March 1995 Resolved
Service fixed fire fighting system for machinery space and cargo hold. SOLAS 60 II/66
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 23 March 1995 Resolved
Make the guaging reports and shell expansion plans available to the Officerin Charge, Marine Inspection for review. SOLAS 60 I/10
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 23 March 1995 Resolved
Remove the electrical cable in the forward bulkhead and weld the hole closed in way of the upper level engine room, portside, behind main engine dirty oil tank._x001C_ SOLAS 60 II/54(b).
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 23 March 1995 Resolved
Crop and renew wasted bulkhead between crews head and the engine room, across from the hospital space. SOLAS 60 II/54(b)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 23 March 1995 Resolved
Permanently close the hole in the bulkhead above starboard main deck engineroom access door. Hole is approximentaly 3 inches by 6 inches. SOLAS 60 II/54(b)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 23 March 1995 Resolved
Remove the BV markings from the loadline and permanently mark with the new load line assigning authority marks. ICLL 1966 ANNEX I/7
Condition: Unknown
Due 29 April 1995
Resolved 10 January 2002
Resolution: Administratively closed due to age of deficiencies.
Documentation
Issued 23 March 1995 Resolved
Permanently exhibit damage control plans. SOLAS 60 II/20
Condition: Unknown
Due 29 March 1995
Resolved 10 January 2002
Resolution: Administratively closed due to age of deficiencies.
Lifesaving
Issued 23 March 1995 Resolved
Repair/replace brake pads on all mooring winches, boom winches and anchor windlasses. SOLAS 74 II-1/26.1
Condition: Unknown
Due 29 April 1995
Resolved 10 January 2002
Resolution: Administratively closed due to age of deficiencies.
Navigation
Issued 23 March 1995 Resolved
Provide a block diagram on the bridge that matches the one posted in the engine room. Provide operating instructions on brige and steering gear room for all modes of operation in a language understood by the crew. _x001C_ 33 CFR 164.35(k)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 23 March 1995 Resolved
Make repairs to wiring in port forward corner of CO2 room so that there is no bare wiring exposed. SOLAS 60 II/27(a)(1)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 23 March 1995 Resolved
Clean oil from deck in steering gear compartment. SOLAS 74 II-1/26.1
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Navigation
Issued 23 March 1995 Resolved
Prove proper operation of steering gear in the non-follow up mode. SOLAS 60 II/29_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 23 March 1995 Resolved
Make repairs to the #3 cargo hatch coaming to the satisfaction of the flag administration. Hole located approximately 2 feet inboard from the aft starboard corner. SOLAS 60 II/17(b)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 23 March 1995 Resolved
Install a means of closing the air pipe located across from the starboard anchor windlass. SOLAS 60 II/17(b)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 23 March 1995 Resolved
Install self-activation smoke signals for bridge life buoys so that they are capable of being quickly released without becoming hung up and fall freely. SOLAS 60 III/21(g)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Accommodation/Occupational Safety
Issued 23 March 1995 Resolved
Repair wasted platforms on forward mast for cargo boom controls. ICLL_x001C_ 1966 ANNEX I/25(4)
Condition: Unknown
Due 29 April 1995
Resolved 10 January 2002
Resolution: Administratively closed due to age of deficiencies.
Lifesaving
Issued 23 March 1995 Resolved
Place all high pressure gas cylinders in proper brackets and place wood between deck and bottom of cylinders. 33 CFR 147.60(b)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 23 March 1995 Resolved
Remove welding cable from bottom of port engine room access door on main deck and repair door sill so door fits tightly. SOLAS 60 II/54(b)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Fire Fighting
Issued 23 March 1995 Resolved
Provide securing device for port main deck engine room access door that canbe opened from both sides.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 23 March 1995 Resolved
Weld the hole closed in bulkhead forward of aft port main deck engine room access door. SOLAS 60 II/54(b)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 23 March 1995 Resolved
Permanently close the opening around the hot water piping coming from main machinery space, located across from chief cooks cabin. SOLAS 60 II/54(b)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Fire Fighting
Issued 23 March 1995 Resolved
Provide spare portable fire extinguishers to the satisfaction of the Flag Administration. SOLAS 60 II/57(b)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Fire Fighting
Issued 23 March 1995 Resolved
Prove proper operation of fire dampners for the engine room ventilation. Damper controls are located on captains deck. SOLAS 60 II/69(a)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Fire Fighting
Issued 23 March 1995 Resolved
Prove proper operation of main fire pumps. SOLAS 60 II/65(b)
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Documentation
Issued 23 March 1995 Resolved
Provide a safe manning certificate. SOLAS 74 V/13_x001C_
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 23 March 1995 Resolved
Clean oil for starboard generator. SOLAS 74 II-1/26.1
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 23 March 1995 Resolved
Clean oil from deck plates, lower level starboard side of main engine. SOLAS 74 II-I/26.1
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Fire Fighting
Issued 23 March 1995 Resolved
Provide two breathing apparatus with interchangeable spare charges. The number of spare charges shall be to the satisfaction of the flag administration. SOLAS 74 II-2/17.3
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 23 March 1995 Resolved
Provide a 406 Mhz EPIRB. SOLAS 74 IV/7.6.1
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 23 March 1995 Resolved
Conduct a fire and abandon ship drill in accordance with vessels muster list and vessel's SOLAS training manual. SOLAS 74 V/13
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 23 March 1995 Resolved
Prove proper operation of general alarm system. SOLAS 74 II/50
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Engineering
Issued 23 March 1995 Resolved
Prove proper operation of oily water separator 15 ppm alarm. MARPOL 74/78 ANNEX I/16
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Engineering
Issued 23 March 1995 Resolved
Install metal plug in place of wood plug on discharge side of oily water separator. SOLAS 60 II/14
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 24 January 1995 Resolved
Clean excessive oil from engine room bilges. SOLAS 60 II/34
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 24 January 1995 Resolved
Repair flex hose loops at CO2 bottles for cargo and machinery space fixed CO2 system. Provide report from class society that system has been properlyserviced and is in operational condition. SOLAS 60 II/65
Condition: Unknown
Due 25 January 1995
Resolved 7 February 1995
Construction/Loadline
Issued 15 July 1994 Resolved
REPLACE GASKET FITTING AROUND BATTERY ROOM DOOR AND REPLACE SEVEN MISSING_x001C_ DOGS FROM DOOR. SOLAS, CHAPTER I, REG XI.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Lifesaving
Issued 15 July 1994 Resolved
PROVIDE THIS OFFICE WITH A CLASS REPORT AS TO THE SEAWORTHINESS OF THE PORT AND STARBOARD LIFE BOAT. SOLAS, CHAPTER III, REG 19._x001C_
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Lifesaving
Issued 15 July 1994 Resolved
RENEW PORT AND STARBOARD EMBARKATION LIGHT BULBS ON MAST. SOLAS, CHAPTER I, REG XI._x001C_ _x001C_ ,_x001C_
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Fire Fighting
Issued 15 July 1994 Resolved
INSTALL FIRE NOZZLE AND SPANNER WRENCH AT 02 DECK AFT FIRE STATION. SOLAS,CHAPTER II-2, REG 4._x001C_
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Construction/Loadline
Issued 15 July 1994 Resolved
RENEW WASTED AND BROKEN MAST GUIDE WIRE ANCHOR PLATES. SOLAS, CHAPTER I,_x001C_ REG XI.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Lifesaving
Issued 15 July 1994 Resolved
RENEW BOUYANT APPARATUS AT AFT LIFE BOAT DECK, PORTSIDE. SOLAS, CHAPTER III, REG 30_x001C_
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Construction/Loadline
Issued 15 July 1994 Resolved
RENEW WEATHER TIGHT DOOR KNIFE EDGE FOR AIR CONDITIONING MACHINERY ROOM ON_x001C_01 DECK. SOLAS, CHAPTER I, REG XI.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Engineering
Issued 15 July 1994 Resolved
REPAIR RAW WATER COOLING PUMPS FOR MAIN ENGINE. SOLAS, CHAPTER II-I, REG_x001C_ XXVI.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Engineering
Issued 15 July 1994 Resolved
REPAIR OILY WATER SEPARATOR. 33 CFR 155.380.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Engineering
Issued 15 July 1994 Resolved
REPAIR PORT GENERATOR EXCESSIVE COOLING WATER AND LUBE OIL LEAKS. SOLAS,_x001C_ CHAPTER II-I, REG XXVI.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Engineering
Issued 15 July 1994 Resolved
SERVICE MAIN ENGINE LUBE OIL PUMP. SOLAS, CHAPTER II-I, REG XXVI.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Construction/Loadline
Issued 15 July 1994 Resolved
MAKE FORECASTLE WATER TIGHT. SOLAS, CHAPTER I, REG XI.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Construction/Loadline
Issued 15 July 1994 Resolved
RENEW BRACKET INSIDE FORECASTLE UNDER BULL NOSE AT INTERSECTION OF BRACKET_x001C_AND MAIN DECK. SOLAS, CHAPTER I, REG XI.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Construction/Loadline
Issued 15 July 1994 Resolved
RENEW APPROXIMATELY TWO FOOT OF WELD PORT SIDE AFT OF BULL NOSE AT THE_x001C_ INTERSECTION OF NO. 1 DECK BEAM AND DECK. SOLAS, CHAPTER I, REG XI.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Construction/Loadline
Issued 15 July 1994 Resolved
REPAIR COMBING,STARBOARD SIDE CARGO HOLD, FORE AND AFT. SOLAS, CHAPTER I,_x001C_REG XI.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Construction/Loadline
Issued 15 July 1994 Resolved
REPAIR PORT AND STARBOARD SIDE CARGO HOLD FRAMES SUPPORTING COMBING, FORE _x001C_AND AFT. SOLAS, CHAPTER I, REG XI.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Navigation
Issued 15 July 1994 Resolved
REPAIR ECHO DEPTH SOUNDER. 33 CFR 164.35(h).
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Navigation
Issued 15 July 1994 Resolved
REPAIR GYROCOMPASS. 33 CFR 164.35(d).
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Construction/Loadline
Issued 15 July 1994 Resolved
RENEW ALL UNSERVICABLE DECK PLATING IN ENGINE ROOM.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Engineering
Issued 15 July 1994 Resolved
REPAIR OR REPLACE WASTED VENTS AND FLAME SCREENS AT NO.2 AND NO.3 FUEL OIL_x001C_TANK VENTS. 46 CFR 56.50-85.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Accommodation/Occupational Safety
Issued 15 July 1994 Resolved
REPAIR NO.1 AND NO.2 FRESH WATER SERVICE PUMP.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Accommodation/Occupational Safety
Issued 15 July 1994 Resolved
PROVIDE HOT AND COLD RUNNING WATER FOR ALL CREW MEMBERS.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Engineering
Issued 15 July 1994 Resolved
REPAIR MAIN ENGINE AND PROVIDE A COPY OF THE CLASS REPORT TO THIS OFFICE._x001C_ SOLAS, CHAPTER II-I, REG 46.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Engineering
Issued 15 July 1994 Resolved
REPLACE SAFETY GUARDS FOR ALL BELT DRIVEN EQUIPMENT.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Lifesaving
Issued 15 July 1994 Resolved
REPLACE WEAK LINK ON THE STARBOARD LIFE RAFT. SOLAS, CHAPTER III, REG 38.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Deck/Cargo
Issued 15 July 1994 Resolved
REPAIR PATCHED AREA ON NO.3 BOOM CABLE WINCH WHERE LEAKING. SOLAS, CHAPTERI, REG XI._x001C_ _x001C_
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Construction/Loadline
Issued 15 July 1994 Resolved
REPAIR OR REPLACE WASTED VENT AND REPLACE CHECK VALVE AT THE FOREPEAK TANK_x001C_VENT. SOLAS, CHAPTER I, REG XI.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Construction/Loadline
Issued 15 July 1994 Resolved
REPAIR OR REPLACE WASTED VENT AND REPLACE CHECK VALVE AT NO.3 BALLAST TANK VENT. SOLAS, CHAPTER I, REG XI.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Lifesaving
Issued 15 July 1994 Resolved
REPLACE REFLECTIVE TAPE, AND ATTACHING GRAB LINE WITH APPROVED NYLON WEBBING ON SIX LIFE RINGS. SOLAS, CHAPTER III, REG 30.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Construction/Loadline
Issued 15 July 1994 Resolved
REPAIR WASTED PLATFORM FRAMES AT NO.1 AND NO.2 BOOM. SOLAS, CHAPTER I,_x001C_ REG XI.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Engineering
Issued 27 June 1994 Resolved
Install proper piping on discharge side of oily water seperator. Remove oil from #3 port ballast tank. Install valve bonnet in engine room for #3 port ballast tank.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Navigation
Issued 27 June 1994 Resolved
A VIOLATION OF 33 C.F.R. 164.33(a)(1)(ii) IN THAT CHARTS # 12221, AND #12222 WERE NOT CORRECTED TO LATEST NOTICE TO MARINERS WHICH WERE READILY AVAILABLE AND EASY TO OBTAIN.
Condition: Unknown
Due 28 June 1994
Resolved 5 July 1994
Navigation
Issued 27 June 1994 Resolved
REPAIR GYRO COMPASS AND PROVE PROPER OPERATION OF SAME TO CAPTAIN OF THE PORT HAMPTON ROADS PRIOR TO DEPARTURE FROM PORT.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Construction/Loadline
Issued 18 May 1994 Resolved
NUMBER 2 STBD BALLAST TANK TAKING ON WATER.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Deck/Cargo
Issued 18 May 1994 Resolved
CARGO HANDLING GEAR SHOWS SEVERE SIGNS OF WASTAGE & WEAR.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Construction/Loadline
Issued 18 May 1994 Resolved
FREE COMMUNICATION BETWEEN FOCSILE & NUMBER 1 HOLD WHICH IS ALLOWING WATER_x001C_INTO THE NUMBER 1 HOLD.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Construction/Loadline
Issued 18 May 1994 Resolved
FREE COMMUNICATION FROM PAINT LOCKER ON MAIN DECK INTO NUMBER 3 HOLD.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Accommodation/Occupational Safety
Issued 18 May 1994 Resolved
ROACHES THROUGHOUT GALLEY, MESSDECK & LIVING SPACES. ILO 147 REG. 2-F-2
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Fire Fighting
Issued 18 May 1994 Resolved
FIREMAIN PIPING ON MAIN DECK HOLED IN THREE LOCATIONS._x001C_ SOLAS CHAPTER II-2, REG. 4 6
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Accommodation/Occupational Safety
Issued 18 May 1994 Resolved
VSL'S PORT GANGWAY SEVERELY WASTED & UNSAFE.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Lifesaving
Issued 18 May 1994 Resolved
VSL HAS 16 COMPRESSED GAS CYLINDERS ON THE OPEN DECK NOT PROPERLY STORED INA RACK & NOT PROPERLY CAPPED. 33 CFR 160.109 VIA 46 CFR 147.1(b)
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Accommodation/Occupational Safety
Issued 18 May 1994 Resolved
MANY CREW ACCOMADATIONS LEAKING WATER THROUGH OVERHEAD ONTO SLEEPING AREAS_x001C_& DECKS. ILO 147 REG. 2-D-1
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Documentation
Issued 18 May 1994 Resolved
VSL'S INTERNATIONAL OIL POLLUTION PREVENTION (IOPP) CERTIFICATE MISSING_x001C_ ITS FORM A SUPPLEMENT.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Lifesaving
Issued 18 May 1994 Resolved
VSL'S PORT & STBD LIFEBOATS MISSING THEIR SEA ANCHORS._x001C_ SOLAS CHAPTER III, REG. 41 8.6
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Navigation
Issued 18 May 1994 Resolved
LARGE SCALE CHART OF SAN JUAN HARBOR NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Navigation
Issued 18 May 1994 Resolved
PRE-ARRIVAL TESTS REQUIRED NOT LOGGED IN SHIP'S LOGBOOK.
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Navigation
Issued 18 May 1994 Resolved
CONTINUOUS RECORDER FOR ECHO DEPTH SOUNDER INOPERABLE.
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Documentation
Issued 18 May 1994 Resolved
COMPLETED PAGES OF OIL RECORD BOOK NOT SIGNED BY THE MASTER.
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Documentation
Issued 18 May 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Lifesaving
Issued 18 May 1994 Resolved
STARBOARD LIFERAFT ANNUAL INSPECTION EXPIRED. _x001C_ SOLAS CHAPTER III, REG. 19 8.1
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Lifesaving
Issued 18 May 1994 Resolved
PORT LIFEBOAT NOT EXERCISED SINCE NEW CREW CAME ABOARD._x001C_ SOLAS CHAPTER III, REG 18 3.4
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Lifesaving
Issued 18 May 1994 Resolved
STARBOARD LIFEBOAT NOT EXERCISED SINCE NEW CREW CAME ABOARD._x001C_ SOLAS CHAPTER III, REG. 18 3.4
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Construction/Loadline
Issued 18 May 1994 Resolved
ENGINEROOM MAIN BILGE PUMP INOPERABLE. SOLAS CHAPTER II-I, REG. 21 1.1
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Fire Fighting
Issued 18 May 1994 Resolved
VSL'S EMERGENCY FIRE PUMP IS REMOVED. SOLAS CHAPTER II-2, REG. 4 3.1.2
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Construction/Loadline
Issued 18 May 1994 Resolved
WATERTIGHT DOORS THROUGHOUT SHIP NOT WATERTIGHT._x001C_ SOLAS CHAPTER II-1, REG. 14 1
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Fire Fighting
Issued 18 May 1994 Resolved
FIRE DRILL NOT CONDUCTED SINCE NEW CREW CAME ABOARD._x001C_ SOLAS CHAPTER III, REG. 18 3.1
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Construction/Loadline
Issued 18 May 1994 Resolved
MANHOLE COVERS FOR BALLAST TANKS ON MAIN DECK WELDED SHUT, NUTS & BOLTS MISSING, & CONCRETED POURED OVER.
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Electrical
Issued 18 May 1994 Resolved
ELECTRIC LIGHTS THROUGHOUT VSL MISSING GLOBES & GUARDS._x001C_ ILO 147 REG. 2-C-5
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Electrical
Issued 18 May 1994 Resolved
GALLEY ELECTRICAL PANEL FULLY EXPOSED. ILO 147 REG. 2-C-5
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Fire Fighting
Issued 18 May 1994 Resolved
ALL FIRE STATIONS MISSING HOSES & EQUIPMENT. _x001C_ SOLAS CHAPTER II-2, REG. 4-7.1
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Fire Fighting
Issued 18 May 1994 Resolved
NOZZLES FOR THE FIRE HOSES NOT OF AN APPROVED DUAL PURPOSE TYPE._x001C_ SOLAS CHAPTER II-2, REG. 4-8.8.4
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Fire Fighting
Issued 18 May 1994 Resolved
VSL HAS NO INTERNATIONAL SHORE CONNECTION. _x001C_ SOLAS CHAPTER II-2, REG. 19
Condition: Unknown
Due 9 June 1994
Resolved 13 June 1994
Engineering
Issued 18 May 1994 Resolved
VSL'S OILY WATER SEPARATOR INOPERABLE.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Engineering
Issued 18 May 1994 Resolved
STARBOARD DIESEL GENERATOR LEAKING DIESEL FUEL FROM THE NUMBER 6 INJECTOR.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Engineering
Issued 18 May 1994 Resolved
PORT DIESEL GENERATOR LEAKING DIESEL FUEL FROM THE NUMBER 6 INJECTOR.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Construction/Loadline
Issued 18 May 1994 Resolved
VSL HAS EXCESSIVE LUBE OIL/DIESEL FUEL THROUGHOUT ENGINEROOM & BILGES.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Accommodation/Occupational Safety
Issued 18 May 1994 Resolved
VSL'S TYPE III MARINE SANITATION DEVICE TANK CAPACITY INADEQUATE FOR_x001C_ NUMBER OF CREWMEMBERS.
Condition: Unknown
Due 9 June 1994
Resolved 15 June 1994
Documentation
Issued 21 March 1993 Resolved
THE VESSEL WAS IN VIOLATION OF SOLAS REGULATION 12 IN THAT THE VESSEL DID NOT HAVE ON BOARD, A VALID SAFETY RADIO TELEGRAPHY CERTIFICATE.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Construction/Loadline
Issued 10 December 1992 Resolved
THE VESSEL DID NOT HAVE A PROPERLY OPERATING OILY WATER SEPARATOR.
Condition: Unknown
Due 21 March 1993
Resolved 11 January 1993
Fire Fighting
Issued 29 October 1992 Resolved
EMERGENCY FIRE PUMP NOT OPERABLE
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Fire Fighting
Issued 10 October 1992 Resolved
VSL'S FIRE HOSES WERE NOT ON STATION A VIOLATION OF SOLAS CH. 2-2 PART A REG 4.7.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Documentation
Issued 10 October 1992 Resolved
FIRE PLAN WAS NOT POSTED ON THE WEATHERDECK A VIOLATION OF SOLAS CH. 2-2 PART A REG 20.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Fire Fighting
Issued 10 October 1992 Resolved
NOZZLES FOR THE FIRE HOSES WERE NOT OF THE APPROVED DUAL PURPOSE TYPE A VIOLATION OF SOALS CH.2-2 PART A REG. 4.8.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Documentation
Issued 10 October 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Engineering
Issued 10 October 1992 Resolved
VSL COULD NOT PROVE PROPER OPERATION OF THE OILY WATER SEPERATOR.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Navigation
Issued 10 October 1992 Resolved
VSL DID NOT HAVE A CHART FOR THE AREA TRANSITED.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Fire Fighting
Issued 10 October 1992 Resolved
VESSEL'S EMER. FIRE PUMP WAS NOT OPERATING PROPERLY (NO SUCTION AT 4.5M DRAFT) A VIOLATION OF SOLAS CH. 2-2 PART C REG 4.3.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Fire Fighting
Issued 10 October 1992 Resolved
VSL DID NOT HAVE AN INTERNATIONAL SHORE CONNECTION A VIOLATION OF SOLAS CH.2-2 PART A REG 19.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Documentation
Issued 10 October 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Navigation
Issued 20 July 1992 Resolved
33 CFR 164.35(A)(1) CHART 11370 NOT ON BOARD.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Navigation
Issued 20 July 1992 Resolved
33 CFR 164.35(G) VESSEL DOES NOT HAVE A MANUVERING FACT SHEET.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Navigation
Issued 20 July 1992 Resolved
33 CFR 164.35(A)(1) THE FOLLOWING CHARTS ARE NOT UPDATED: 11363,11364,11361,11368.
Condition: Unknown
Due 3 December 1993
Resolved 3 December 1993
Navigation
Issued 14 April 1992 Resolved
SOLENOID FOR #2 STEERING PUMP STUCK OPEN, ALLOWING STEERING RAM TO TRAVEL TO THE FULL RIGHT POSITION.
Condition: Unknown
Due 14 April 1992
Resolved 10 January 2002
Resolution: Administratively closed due to age of deficiencies.
Construction/Loadline
Issued 28 September 1991 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPERATOR AND ALARM PRIOR TO RETURN TOA U.S. PORT.
Condition: Unknown
Due 11 October 1991
Resolved 10 October 1991
Deck/Cargo
Issued 19 September 1991 Resolved
Vessel had no fixed containment or enclosed deck area under or around the port or starboard fuel oil manifold_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Accommodation/Occupational Safety
Issued 19 September 1991 Resolved
Vessel did not have Pollution Placards posted in the engine room._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 October 1991
Resolved 18 October 1991
Engineering
Issued 19 September 1991 Resolved
Vessel failed to have an operable Oil Water Separator.
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Accommodation/Occupational Safety
Issued 19 September 1991 Resolved
Vessel failed to have certification label affixed to MSD.
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Documentation
Issued 12 June 1989 Resolved
EXPIRED SOLAS SAFETY RADIOTELEGRAPHY CERTIFICATE. SOLAS REGULATION 12 CH. 1
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Navigation
Issued 12 June 1989 Resolved
VESSEL'S DEVIATION TABLE OUTDATED 33 CFR 164.35(C) 33USC1232
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Documentation
Issued 12 June 1989 Resolved
POLLUTION PLACARD NOT PROPERLY POSTED 33 CFR 155.450(A) 33 USC 1908(B)(1)
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Documentation
Issued 12 June 1989 Resolved
VESSEL'S OIL TRANSFER PROCEDURES WERE INCOMPLETE. 33 CFR 155.750 33 CFR 155.720 33 USC 1321(J)(2)
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Navigation
Issued 9 November 1988 Resolved
VESSEL OVER 1600 GROSS TONS ENTERED US PORT, SAVANNAH, GA. WITHOUT A CURRENT/CORRECTED COPY OF COAST GUARD LIGHT LIST VOLUME 111. A VIOLATION OF 33 CFR 164.33(2)(II)
Condition: Unknown
Due 9 November 1988
Resolved 9 November 1988
Navigation
Issued 9 November 1988 Resolved
VESSEL OVER 1600 GROSS TONS ENTERED US PORT, SAVANNAH, GA. WITHOUT A CURRENT/CORRECTED COPY OF THE US COAST PILOT VOLUME 4. A VIOLATION OF 33 CFR 164.33(2)(I)
Condition: Unknown
Due 9 November 1988
Resolved 9 November 1988
Navigation
Issued 14 September 1987 Resolved
33CFR164.33(A)(1)(II) THE VESSEL'S CHARTS WERE NOT CURRENT OR CORRECTED.
Condition: Unknown
Due 14 September 1987
Resolved 14 September 1987
Documentation
Issued 14 September 1987 Resolved
33CFR155.720 THE VESSEL'S OIL TRANSFER PROCEDURES WERE INCOMPLETE.
Condition: Unknown
Due 14 September 1987
Resolved 14 September 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.