Records from 2001 to 2026. Most recent: inspection, 20 February 2026.
Documentation record
Registered dimensions (L × B × D)220.5 ft × 54.0 ft × 16.0 ft
Registered tonnagegross 1,449 / net 1,026
ITC dimensions (L × B × D)220.5 ft × 54.0 ft × 16.0 ft
ITC tonnagegross 1,815 / net 544
BuilderLEEVAC OFFSHORE SERVICES INC · JENNINGS, LA, UNITED STATES · built 2001
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 July 2026 · expires 31 August 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1449 - Regulatory (Subpart C or D), Gross Ton
1815 - Convention (Subpart B), Gross Ton
1026 - Regulatory (Subpart C or D), Net Ton
544 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 46
20 February 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8313606
21 January 2026
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8299764
28 August 2025
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8219571
13 June 2025
MTSA/ISPS Verification · Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8153050
8 April 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8108376
2 October 2024
Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8013748
29 July 2024
In-Service Inspection · Plan Review (Other than "T")
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7972443
26 June 2024
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7943185
30 May 2024
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7922994
25 November 2023
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7829358
11 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7807109
27 September 2023
COI Inspection · Administrative Inspection · ACP Handover Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7789848
4 March 2016
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5973730
3 June 2014
Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4885303
21 March 2014
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4819832
18 July 2012
SIP Initial Entry · Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4382916
22 February 2011
Drydock Exam · COI Inspection · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3949787
14 October 2010
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3869754
6 October 2010
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3864687
12 May 2009
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3473330
21 April 2009
Administrative Inspection · Internal Structural Exam · MARPOL Annex VI Survey · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3457740
18 April 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3187268
17 April 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3189006
3 March 2008
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3160188
29 February 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3186996
3 July 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2982100
5 June 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2952591
27 May 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2944514
15 May 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2930877
25 April 2006
Hull Examination · MARPOL Annex I Examination · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2629481
31 January 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2576525
31 January 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2576542
25 July 2005
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2439291
25 July 2005
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2439341
27 June 2005
Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2404807
17 March 2005
Administrative Inspection · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2312606
14 June 2004
MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2098233
20 April 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2048381
9 April 2004
Hull Examination · Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2050737
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979392
6 October 2003
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1922461
9 September 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1673243
26 June 2002
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1636981
2 April 2002
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1786957
30 November 2001
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 773193
19 April 2001
Hull Examination · Initial Certification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1464387
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 16 July 2025
Resolved
The company and the ship shall comely with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations with any additional requirements which may be established by the company. Vessel's crew is not logging engineering maintenance. Ensure maintenance logging procedures are implemented by the company.
74 SOLAS (20) IX 3.1
ISM Code A 10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2025
Resolved 18 July 2025
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 October 2024
Resolved
STBD oil cooler for STBD ME stared leaking oil.Repair damaged oil cooler on STBD main engine to the satisfaction of the USCG Marine Inspector prior to STBD ME operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 October 2024
Resolved 3 October 2024
Resolution: vessel replaced leaking plates in oil/plate cooler
Lifesaving › Lifebuoys › Stowage
Issued 22 February 2011
Resolved
Bridge Buoy launching device did not allow the ring buoy to deploy to the water. The Bridge Buoy dropped to the deck below.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2011
Resolved 24 March 2011
Resolution: Launching device repaired.
Operations/Management › Drills/Instruction › Fire
Issued 22 February 2011
Resolved
Fire drill to be completed again due to Structural Fire protection requiments being inop. Doors in galley were tied open removing the layer of protection.
Action required: 705 - Other - as specified
Due 6 April 2011
Resolved 24 March 2011
Resolution: Satisfactory drill completed
Lifesaving › Inflatable Liferafts › Float Free
Issued 22 February 2011
Resolved
Installation of additional life rafts for the portable quarters were not installed float free.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 April 2011
Resolved 24 March 2011
Resolution: Launching mech. has been inspected sat.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 22 February 2011
Resolved
The installed Fire detection pln is displaying a "trouble" alarm. Vsl stated it was possible trouble alarm was from the incomplete installation of the portable quarters.
Action required: 705 - Other - as specified
Due 6 April 2011
Resolved 24 March 2011
Resolution: Third party completed repairs. Test Sat.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 22 February 2011
Resolved
Fire Control plans need to reflect the additional life rafts and portable quarters
Action required: 705 - Other - as specified
Due 6 April 2011
Resolved 24 March 2011
Resolution: Fire Saftey Plan has been updated.
Stability › Incline Test › General
Issued 6 October 2010
Resolved
Vessel installed Crane changing stability characteristics of vessel and does not have current stability letter on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2010
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 6 October 2010
Resolved
Company made alterations to the vessel by adding a 40 ton crane on the deck of the vessel without notifying local OCMI of alterations to the vessel prior to starting on the installation. Submit Plans and drawing to USCG MSC for reiview.
Action required: 705 - Other - as specified
Resolved 24 March 2011
Resolution: ABS provided 10-82 completeion ltr for 30 ton crane instalation.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 17 March 2005
Resolved
PROVIDE APPROVED AUTOMATION TEST PROCEDURES.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 27 June 2005
Resolution: Stamped and approved by MSU Lake Charles.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 17 March 2005
Resolved
PROVIDE CRANE CERTIFICATION FROM API CERTIFIED SOURCE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 10 June 2009