Records from 1985 to 2005. Most recent: inspection, 28 November 2005.
Inspection history · 28
28 November 2005
Random ISPS/MTSA/PSC
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2541725
8 November 2005
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2530857
14 January 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2275347
14 January 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2277795
12 January 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2273300
13 September 2004
ISPS II Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2194660
13 September 2004
NPV Safety Exam · Ballast Water Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2194664
9 September 2004
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2191754
30 July 2003
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1861625
26 July 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1862609
16 February 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1752228
17 November 2002
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1706621
15 June 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1627312
25 October 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 283483
25 October 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 284370
25 October 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 287616
9 September 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 432472
30 November 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 469414
22 November 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 422897
20 July 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 418425
28 June 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 655206
26 June 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 392420
12 July 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 380290
21 May 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 337368
14 June 1989
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 330932
12 February 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 314235
28 February 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 511926
17 May 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 301672
Fire Fighting › Firemans Outfit
Issued 30 July 2003
Resolved
Vessel is required to have two complete fire suits in board. 2 fire hoods need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2003
Resolution: Two replacement fire suits purchased and received onboard on this date. Deficiency cleared.
Engineering › Generator (propulsion-electric)
Issued 15 June 2002
Resolved
Excess oil on Main Generator and surrounding bilges. Solas 74/78 I/11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 November 2002
Resolution: VISUALLY INSPECTED TO SATISFACTORY LEVEL
Engineering
Issued 15 June 2002
Resolved
Water leak in pipe leading to center Generator Heat Exchanger. Solas 74/78 II-1/41.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 November 2002
Resolution: VISUALLY INSPECTED TO SATISFACTORY LEVEL
Fire Fighting › Fire Pumps
Issued 15 June 2002
Resolved
Seal leak on #2 Main Fire Pump. Solas 74 II-2 / 21. LEGACY COMPONENT DESC: Gland Sealing
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 November 2002
Resolution: VISUALLY INSPECTED TO SATISFACTORY LEVEL
Lifesaving › Lifeboat
Issued 15 June 2002
Resolved
Limit Switch on Starboard Lifeboat is inoperable. Solas 74 III/ 19.2.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 November 2002
Resolution: VISUALLY INSPECTED TO SATISFACTORY LEVEL
Fire Fighting
Issued 25 October 2000
Resolved
FIRE DOOR TO GALLEY REQUIRES REPAIR OR REPLACEMENT TO CLOSE PROPERLY, SOLAS60 CH. 11 REG 23, CORRECT PRIOR TO NEXT U.S. PORT AFTER OVERSEAS
Condition: Unknown
Due 26 October 2000
Resolved 15 June 2002
Resolution: Fire door to galley has been repaired and properly closes.
Construction/Loadline
Issued 25 October 2000
Resolved
WEATHER TIGHT DOOR TO GALLEY REQUIRES REPAIR OR REPLACEMENT TO CLOSE PROPERLY, ICLL 66 REG 16. CORRECT PRIOR TO NEXT U.S. PORT AFTER OVERSEAS.
Condition: Unknown
Due 25 October 2000
Resolved 15 June 2002
Resolution: Weather tight door to galley has been repaired and properly closes.
Accommodation/Occupational Safety
Issued 9 September 1999
Resolved
GENERAL SANITARY CONDITIONS OF GALLEY UNSATISFACTORY. DIRTY FLOORS, WALLS AND DRAINS.
Condition: Unknown
Due 9 October 1999
Resolved 8 October 1999
Accommodation/Occupational Safety
Issued 9 September 1999
Resolved
VENT SCREEN OVER GALLEY MUST BE REPLACED.
Condition: Unknown
Due 9 October 1999
Resolved 8 October 1999
Lifesaving
Issued 9 September 1999
Resolved
UNSAFE STOWAGE OF COMPRESSED AIR BOTTLES.
Condition: Unknown
Due 9 October 1999
Resolved 8 October 1999
Engineering
Issued 9 September 1999
Resolved
ENSURE FLAME SCREENS ARE PRESENT AND IN GOOD CONDITION ON FUEL TANK VENTS AS NECESSARY.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Fire Fighting
Issued 9 September 1999
Resolved
ENSURE EMERGENCY FIRE PUMP IS IN PROPER WORKING ORDER TO THE SATISFACTION OF USCG AND CLASS PRIOR TO DEPARTING THE PORT OF HAMPTON ROADS.
Condition: Unknown
Due 21 September 1999
Resolved 21 September 1999
Lifesaving
Issued 9 September 1999
Resolved
PROPERLY FASTEN MANHOLE COVER IN THE PORTSIDE ENGINE ROOM PIPE TUNNEL.
Condition: Unknown
Due 21 September 1999
Resolved 21 September 1999
Accommodation/Occupational Safety
Issued 9 September 1999
Resolved
INSECTS IN DRY STORAGE AREA MUST BE EXTERMINATED.
Condition: Unknown
Due 9 October 1999
Resolved 8 October 1999
Accommodation/Occupational Safety
Issued 9 September 1999
Resolved
HEAD IN HOSPITAL SPACE INOPERABLE.
Condition: Unknown
Due 9 October 1999
Resolved 8 October 1999
Accommodation/Occupational Safety
Issued 9 September 1999
Resolved
VARIOUS COMBINATIONS OF SINKS, SHOWERS AND HEADS IN MOST CREW CABINS ARE INOPERABLE IN THAT THEY HAVE NO RUNNING WATER.
Condition: Unknown
Due 9 October 1999
Resolved 8 October 1999
Electrical
Issued 20 July 1998
Resolved
THE VESSEL NEEDS TO INSTALL GUARDS ON LIGHTING THROUGHOUT THE VESSEL(ENGINEROOM, PASSAGEWAYS, BOSUN HOLE, CREW CABINS) PRIOR TO IT'S NEXTU.S. PORT.
Condition: Unknown
Due 22 November 1998
Resolved 22 November 1998
Navigation
Issued 26 June 1996
Resolved
U.S. LIGHTLIST VOL. II NOT CORRECTED.
Condition: Unknown
Due 26 June 1996
Resolved 1 July 1996
Navigation
Issued 26 June 1996
Resolved
INOPERABLE ECHO DEPTH SOUNDER. ISSUED LETTER OF DEVIATION._x001C_ _x001C_ _x001C_ CORRECT PRIOR TO DEPARTURE_x001C_
Condition: Unknown
Due 27 June 1996
Resolved 28 June 1996
Electrical
Issued 26 June 1996
Resolved
instal guards on lighting throughout vessel prior to next U.S. port, per SOLAL CH. II, REG 41 & 45.
Condition: Unknown
Due 12 July 1996
Resolved 28 June 1996
Navigation
Issued 26 June 1996
Resolved
U.S. COAST PILOT VOL.3 NOT CORRECTED.
Condition: Unknown
Due 26 June 1996
Resolved 1 July 1996
Electrical
Issued 12 July 1995
Resolved
Install guards on lighting throughout vessel(engineroom, passageways and bosun hole), prior to next U. S. port, per SOLAS Chap II, Reg 41 & 45
Condition: Unknown
Due 22 July 1998
Resolved 22 July 1998
Navigation
Issued 12 July 1995
Resolved
Make permanent repairs to standby radar, prior to departure from port, per SOLAS Chap V, Reg 12(h)
Condition: Unknown
Due 26 July 1995
Resolved 26 July 1995
Fire Fighting
Issued 12 July 1995
Resolved
Make permanent repairs to the following fire main leaks: a)#2 cargo hold port side aft pipe split & flange leaking, b) aft #4 cargo hold stbd side at hydrant (soft patch), prior to departure, per SOLAS Chap II, Reg 4
Condition: Unknown
Due 26 July 1995
Resolved 26 July 1995
Deck/Cargo
Issued 12 July 1995
Resolved
Clean oil from deck from leaking hydraulic gear, prior to departure, per 33C.F.R. 151.10
Condition: Unknown
Due 26 July 1995
Resolved 26 July 1995
Navigation
Issued 21 May 1990
Resolved
CHART NUMBER 18661 19TH ED. 01JUL89, NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINERS CORRECTIONS AS FOLLOWS: 1990-2,5,7,13.
Condition: Unknown
Due 26 July 1995
Resolved 26 July 1995
Navigation
Issued 21 May 1990
Resolved
U.S. COAST PILOT 25TH ED. 1990, NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINER CORRECTIONS AS FOLLOWS: 1990-3,7,11,15.
Condition: Unknown
Due 26 July 1995
Resolved 26 July 1995
Navigation
Issued 21 May 1990
Resolved
USCG LIGHT LIST 1990 VOLUME 6 NOT CURRENTLY CORRECTED. MISSING NOTICE TO MARINER CORRECTIONS AS FOLLOWS: 1990-2,3,5,6,7,10,12,14,15,18.
Condition: Unknown
Due 26 July 1995
Resolved 26 July 1995
Navigation
Issued 14 June 1989
Resolved
VESSEL HAD NO TIDAL CURRENT TABLE AS PER 33CFR164.33(A)(3)(II).
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Navigation
Issued 14 June 1989
Resolved
CHARTS FOR AREA TRANSITTED NOT CORRECTED AS PER 33CFR164.33(A)(1)(II).
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Navigation
Issued 14 June 1989
Resolved
VESSEL HAD NO CORRECTIONS TO U.S. COAST PILOT FOR AREA TRANSITTED AS PER 33CFR164.33(A)(2)(I).
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Navigation
Issued 12 February 1987
Resolved
OUTDATED CHART #11370
Condition: Unknown
Due 12 February 1987
Resolved 12 February 1987
Navigation
Issued 12 February 1987
Resolved
OUTDATED U.S. COAST PILOT AND OUTDATED FOREIGN EQUIVALENT.
Condition: Unknown
Due 12 February 1987
Resolved 12 February 1987