Records from 1987 to 1998. Most recent: inspection, 25 October 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
25 October 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 422023
17 January 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 334801
9 January 1990
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 334773
9 January 1990
Certificate of Compliance
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1222479
17 July 1989
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 449790
30 December 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 327637
30 December 1988
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1196551
27 August 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 490423
27 August 1987
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1000227
Deck/Cargo
Issued 25 October 1998
No resolution recorded
PRIOR TO LOADING CARGO IN THE UNITED STATES, INSTALL AND PROVE PROPER OPERATION OF THE CARGO OVERFILL ALARM SYSTEM.
Condition: Unknown
Due 25 October 1998 — due date passed with no resolution recorded
Deck/Cargo
Issued 25 October 1998
No resolution recorded
PRIOR TO NEXT U.S. VOYAGE, PERMANENTLY INSTALL TUBING FOR PORT STRIPPING PUMP PRESSURE GAUGE, CARGO PUMP ROOM.
Condition: Unknown
Due 25 November 1998 — due date passed with no resolution recorded
Deck/Cargo
Issued 25 October 1998
No resolution recorded
PRIOR TO NEXT U.S. VOYAGE, MAKE PERMANENT REPAIRS TO THE STEAMS HEATING COILS IN CARGO TANK NO. 2 CENTER.
Condition: Unknown
Due 25 November 1998 — due date passed with no resolution recorded
Lifesaving
Issued 25 October 1998
No resolution recorded
PRIOR TO NEXT U.S. VOYAGE, REPAIR LEAKS AND REMOVE HYDRAULIC OIL FROM UNDERNEATH CARGO CONTROL ROOM PANELBOARD.
Condition: Unknown
Due 25 November 1998 — due date passed with no resolution recorded
Electrical
Issued 25 October 1998
No resolution recorded
PRIOR TO NEXT U.S. VOYAGE, PROPERLY BLOCK AND BRACE BATTERIES AT THE EMERGENCY GENERATOR.
Condition: Unknown
Due 25 November 1998 — due date passed with no resolution recorded
Electrical
Issued 25 October 1998
No resolution recorded
PRIOR TO NEXT U.S. VOYAGE, PROVIDE ELECTRICAL PROOF MATTING IN FRONT ON THEEMERGENCY GENERATOR SWITCHBOARD.
Condition: Unknown
Due 25 November 1998 — due date passed with no resolution recorded
Deck/Cargo
Issued 25 October 1998
No resolution recorded
PRIOR TO NEXT U.S. VOYAGE, PERMANENTLY INSTALL EXPLOSTION PROOF PHONE SYSTEM IN CARGO PUMP ROOM, FOR COMMS W/CARGO CONTROL ROOM.
Condition: Unknown
Due 25 November 1998 — due date passed with no resolution recorded
Deck/Cargo
Issued 25 October 1998
No resolution recorded
PRIOR TO NEXT U.S. VOYAGE, PROVE PROPER OPERATION OF THE MANIFOLD EMERGENCYSTOPS FOR THE CARGO PUMPS.
Condition: Unknown
Due 25 November 1998 — due date passed with no resolution recorded
Deck/Cargo
Issued 25 October 1998
No resolution recorded
PROVE PROPER OPERATION OF THE PUMP ROOM GAS DETECTION SYSTEM, UPON COMPLETION OF INSTALLATION.
Condition: Unknown
Due 25 November 1998 — due date passed with no resolution recorded
Deck/Cargo
Issued 25 October 1998
No resolution recorded
PRIOR TO NEXT U.S. VOYAGE, STENCILE CARGO PIPING WITH THE LAST HYDROSTATIC TEST DATE AND PRESSURE (AUG98).
Condition: Unknown
Due 25 November 1998 — due date passed with no resolution recorded
Navigation
Issued 9 January 1990
Resolved
VSL FAILED TO REPORT A CASUALTY OF ITS NAVIGATION EQUIPMENT AS REQUIRED BY 33CFR164.53(B)
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Navigation
Issued 9 January 1990
Resolved
REPAIR AND MAKE OPERATIVE THE SECONDARY RADAR.
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Navigation
Issued 30 December 1988
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH THE DEVICE TO CONTINUOUSLY RECORD THE DEPTH SOUNDINGS INOPERATIVE.
Condition: Unknown
Due 30 December 1988
Resolved 30 December 1988
Engineering
Issued 30 December 1988
Resolved
NO FIXED CONTAINMENT OR ENCLOSED DECK AREA UNDER OR AROUND VESSEL'S FUEL OIL AND BULK LUBRICATING OIL FILL PIPES AND VENTS.
Condition: Unknown
Due 30 December 1988
Resolved 30 December 1988
Documentation
Issued 30 December 1988
Resolved
VESSEL COULD NOT PRODUCE A CURRENT RECORD OF A PROPER STATIC LIQUID PRESSURE TEST OF THE CARGO PIPING.
Condition: Unknown
Due 30 December 1988
Resolved 30 December 1988
Navigation
Issued 30 December 1988
Resolved
VESSEL'S SECONDARY RADAR WAS FOUND TO BE INOPERATIVE WHILE VESSEL WAS AT BERTH.
Condition: Unknown
Due 30 December 1988
Resolved 30 December 1988
Navigation
Issued 30 December 1988
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH AN INOPERATIVE ECHO DEPTH SOUNDINGDEVICE.
Condition: Unknown
Due 30 December 1988
Resolved 30 December 1988
Navigation
Issued 30 December 1988
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITHOUT REPORTING INOPERATIVE NAVIGATIONAL EQUIPMENT.
Condition: Unknown
Due 28 October 1998
Resolved 28 October 1998
Navigation
Issued 30 December 1988
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITHOUT CHART 12333 (26 ED) ON BOARD.
Condition: Unknown
Due 28 October 1998
Resolved 28 October 1998
Navigation
Issued 30 December 1988
Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITHOUT CONDUCTING THE REQUIRED PRE- ARRIVAL TEST AS REQUIRED BY 33 CFR 164.25(A).
Condition: Unknown
Due 28 October 1998
Resolved 28 October 1998
Deck/Cargo
Issued 30 December 1988
Resolved
MAKE PERMANENT REPAIRS TO ALL VALVES AND CARGO PUMPS IN CARGO PUMP ROOM THAT SHOW EXCESSIVE LEAKAGE OF PRODUCT. REPAIRS SHALL BE SATISFACTORY COMPLETED PRIOR TO NEXT TRANSFER OF CARGO.
Condition: Unknown
Due 30 December 1988
Resolved 30 December 1988
Accommodation/Occupational Safety
Issued 27 August 1987
Resolved
MARINE SANITATION DEVICE NOT OF AN APPROVED TYPE, ALSO INOPERATIVE.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987