Records from 1986 to 1994. Most recent: inspection, 16 June 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 7
16 June 1994
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 367637
8 June 1994
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1019947
6 June 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 367433
3 June 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 464958
3 June 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1362997
30 October 1990
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 340644
3 April 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 307850
Deck/Cargo
Issued 6 June 1994
Resolved
VESSELS FLAME SCREENS WERE NOT 30X30 OR DOUBLED 20X20 MESH.
Condition: Unknown
Due 1 August 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 3 June 1994
Resolved
REMOVE EXCESS OIL FROM INSIDE OF CONTAINMENT IN STEERING FLAT.
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Navigation
Issued 3 June 1994
Resolved
PROVIDE AND INSTALL COTTER KEYS ON CONTROL LINKAGE FOR STEERING GEAR.
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Engineering
Issued 3 June 1994
Resolved
MAKE AND MAINTAIN TEMPORARY REPAIRS TO FUEL OIL CONTAINMENT'S (#2 FUEL OIL TANKS PORT AND STBD SIDE) AND (PORT FUELING STATION)
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Engineering
Issued 3 June 1994
Resolved
PROVIDE AND INSTALL 30X30 SCREEN MESH IN ALL FUEL OIL VENTS.
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Unknown
Issued 3 June 1994
Resolved
PROVIDE AND INSTALL LOCKING DEVICES FOR (OWS) OILY WATER SEPERATOR OVERBOARD DISCHARGE VALVE.
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Accommodation/Occupational Safety
Issued 3 June 1994
Resolved
PROVIDE AND INSTALL LOCKING DEVICES ON (MDS) MARINE SANITATION DEVICES OVERBOARD DISCHARGE VALVES.
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Lifesaving
Issued 3 June 1994
Resolved
PROPERTLY REINSTALL HYDRO RELEASE FOR 6 MAN LIFE RAFT FORWARD.
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Fire Fighting
Issued 3 June 1994
Resolved
REWORK/REPAIR OR REPLACE TWO (2) FIRE STATION NOZZLES ON MAIN DECK.
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Navigation
Issued 30 October 1990
Resolved
FAILED TO CONDUCT 12 HOURS PRE-ARRIVAL TESTS AS REQUIRED BY 164.25(A)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 June 1994
Resolved 17 June 1994
Navigation
Issued 3 April 1986
Resolved
A VIO OF 33 CFR 33 164.30 IN THAT A CURRENTLY CORRECTED U.S. COAST PILOT VOL 3 OR ITS FOREIGN EQUIV AS REQ BY 33 CFR 164.33(A)(2)(I) WAS NOT O/B. THE VSL HAD O/B U.S. COAST PILOT VOL 3 DTD 1985 WITH NO CORRECTIONS.
Condition: Unknown
Due 3 April 1986
Resolved 3 April 1986
Documentation
Issued 3 April 1986
Resolved
A VIO OF 33 CFR 155.750 IN THAT THE OTP REQ BY 33 CFR 155.720 WERE INCOMPLETE IN THAT THEY DID NOT CONTAIN: PROCEDURE FOR TOPPING OFF TANKS, REPORTING OIL DISCHARGES INTO THE WATER, NUMBER OF PERSONS REQ ON DUTY DURING OIL TRANSFER OPS, DUTIES FOR TENDING VSL'S MOORINGS,AND DUTIES/TITLE
Condition: Unknown
Due 3 April 1986
Resolved 3 April 1986