Records from 1984 to 1998. Most recent: inspection, 15 January 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
15 January 1998
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 411742
13 April 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 540064
4 January 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 133741
4 January 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 484536
1 October 1992
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1244062
29 June 1992
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 953147
9 May 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 343681
9 May 1991
Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 922421
31 October 1988
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 326367
31 October 1988
Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 889377
25 May 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 522601
7 October 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 318873
7 October 1987
Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1018588
29 December 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 522612
19 June 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 310148
19 June 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1292544
24 April 1985
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 301873
1 November 1984
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 523657
Navigation
Issued 15 January 1998
Resolved
Telemotor pump motor burned out. Motor removed by crew, sent out for replacement/repair, and reinstalled. Class surveyor unable to attend to verify repair, arranged to attend at NPOC, Bayway NJ.
Condition: Unknown
Due 16 January 1998
Resolved 10 July 2002
Fire Fighting
Issued 15 January 1998
Resolved
Emergency diesel fire pump flywheel missing sveral teeth, air motor would _x001C_ not start engine. Ch Eng found gear ring in spares, planned to install on 15 Jan 98. Class surveyor unable to attend, made arrangements to attend _x001C_ vessel at NPOC, Bayway NJ.
Condition: Unknown
Due 16 January 1998
Resolved 10 July 2002
Fire Fighting
Issued 29 June 1992
Resolved
EDUCTOR LINE FROM ENGINEROOM FIRE PUMP MANIFOLD WASTED. BLANK OFF EDUCTOR AND FIRE MAIN MANIFOLD. MAKE PERMANENT REPAIRS.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Deck/Cargo
Issued 29 June 1992
Resolved
TANK CLEANING HEATER'S LINE HOLED.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Fire Fighting
Issued 29 June 1992
Resolved
CO2 AND FOAM PORTABLE FIRE EXTINGUISHERS PAST DUE FOR SERVICING.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Documentation
Issued 29 June 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Navigation
Issued 29 June 1992
Resolved
LIGHT LIST NOT CURRRENTLY CORRECTED.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Navigation
Issued 29 June 1992
Resolved
COAST PILOT NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Lifesaving
Issued 29 June 1992
Resolved
PROVE PROPE OPERATION OF COMBUSTIBLE GAS DETECTOR.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Fire Fighting
Issued 29 June 1992
Resolved
PROVIDE PROOF FOAM SAMPLE IS WITHIN SPECS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 July 1992
Resolved 14 October 1992
Lifesaving
Issued 29 June 1992
Resolved
PROVIDE FOURTH FIREMANS OUTFIT.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Fire Fighting
Issued 29 June 1992
Resolved
ONE NOZZLE BAD AND SIX HOSES HOLED OR QUICK CONNECT TABS BROKEN OFF.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Deck/Cargo
Issued 29 June 1992
Resolved
OIL TRANSFER PROCEDURES MISSING PIPING DIAGRAM.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Navigation
Issued 29 June 1992
Resolved
RUDDER ARRESTING GEAR FAILS TO HAVE POWER OPERATED PUMP FOR REFILLING ACTUATORS.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Deck/Cargo
Issued 29 June 1992
Resolved
INERT GAS SYSTEM'S ALARMS AND TRIPS NOT EXAMINED. VSL HAD NO CARGO ABD AND TANLS OPEN FOR CLEANING.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992
Construction/Loadline
Issued 29 June 1992
Resolved
PROVE PROPER OPERATION OF BALLAST DISCHARGE MONITOR.
Condition: Unknown
Due 20 July 1992
Resolved 23 December 1992
Deck/Cargo
Issued 29 June 1992
Resolved
REPAIR LEAK IN #3 CARGO PUMP COOLING LINE. VSL MAY NOT USE #3 PUMP IN U.S. WATERS UNTIL REQ CLEARED.
Condition: Unknown
Due 24 December 1992
Resolved 24 December 1992