← All vessels
PANORMOS WIND
PANORMOS WIND is a 1977 freight ship. The Coast Guard has recorded 11 inspections since 1985, most recently in May 2000, along with 9 deficiencies — 1 with no resolution recorded — and 1 operational control.
Records from 1985 to 2000. Most recent: inspection, 10 May 2000.
- Built
- 1977
- Last inspected
- 10 May 2000
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7357268 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
P3IW4
226671
Flag
ARGENTINA
—
Maury page id
psix-226671
Inspections, by type
…with no type recorded11
…past their stated due date1
Years with a record
7 calendar years (1985–2000)
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it7230 - Regulatory (Subpart C or D), Net Ton
15644 - Dead Weight, Ton
9590 - Regulatory (Subpart C or D), Gross Ton
15644 - Dead Weight, Ton
9590 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
10 May 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 277646
29 January 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 335090
15 June 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 516499
9 January 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 327785
24 October 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 519736
19 December 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 501434
8 December 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 320090
4 April 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 500497
22 September 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 495903
19 September 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 311534
9 September 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 304113
Deficiency record · 9
Navigation
Issued 10 May 2000
Resolved
CALIBRATE RUDDER ANGLE INDICATOR ON BRIDGE TO MATCH INDICATOR ON STEERING GEAR._x001C_ 33 CFR 164.35
Fire Fighting
Issued 10 May 2000
Resolved
CONDUCT FIRE DRILL TO SATISFACTION OF COAST GUARD INSPECTOR._x001C_ SOLAS 74 X/4
Fire Fighting
Issued 10 May 2000
Resolved
REPLACE HOSES ON 2 PORTABLE FIRE EXTINGUISHERS, ONE ON LIFEBOAT DECK AND ONE ON MAIN DECK.
Engineering
Issued 10 May 2000
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR._x001C_ MARPOL 73/78 ANNEX I/16
Fire Fighting
Issued 10 May 2000
Resolved
PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP._x001C_ SOLAS 74 II-2/21_x001C_
Fire Fighting
Issued 10 May 2000
Resolved
REPAIR/ REPLACE ORIGINAL EXHAUST GASKET ON EMERGENCY FIRE PUMP._x001C_ SOLAS 74 II-2/21_x001C_ _x001C_
Engineering
Issued 10 May 2000
No resolution recorded
REPAIR/RENEW AS ORIGINAL SALT WATER INLET PIPE TO #3 GENERATOR COOLING PUMP._x001C_ SOLAS 60 I/11
Engineering
Issued 10 May 2000
Resolved
REPAIR/REPLACE AS ORIGINAL OUTLET PIPE FOR SALT WATER COOLING FOR GENERATORS. _x001C_ SOLAS 60 I/11
Navigation
Issued 8 December 1987
Resolved
VESSEL'S 10 CM RADAR WAS NOT MAINTAINED IN OPERABLE CONDITION AS REQUIRED BY 33 CFR 164.11(R).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National