Records from 1985 to 1993. Most recent: inspection, 26 March 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
26 March 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 357098
14 August 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 648376
31 July 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 352014
31 July 1992
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 950516
3 April 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 342906
3 April 1991
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 946393
3 April 1991
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1240272
20 September 1989
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 445049
20 September 1989
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1205368
13 December 1988
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 897875
17 September 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 519425
11 January 1988
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 494120
19 November 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1026774
19 November 1987
Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1332600
15 October 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 537204
14 July 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 310086
2 July 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 302903
Engineering
Issued 31 July 1992
Resolved
4 CARGO VENT FLAME SCREENS WERE TORN.
Condition: Unknown
Due 1 August 1992
Resolved 3 August 1992
Construction/Loadline
Issued 31 July 1992
Resolved
DISCHARGING OIL INTO BILGES. MACHINERY CONTAINMENTS HAD EXCESSIVE OIL IN THEM AND WERE OVER FLOWING INTO THE BILGE.
Condition: Unknown
Due 3 August 1992
Resolved 3 August 1992
Unknown
Issued 31 July 1992
Resolved
Seal containment around bunkering connections prior to arrival at next U.S.port.
Condition: Unknown
Due 31 July 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 31 July 1992
Resolved
Repair fuel pump leak and remove excess oil from foundation containment prior to transferring cargo.
Condition: Unknown
Due 7 August 1992
Resolved 7 August 1992
Deck/Cargo
Issued 31 July 1992
Resolved
Repair leak to riser valve on inert gas system prior to arrival at next U.S. port.
Condition: Unknown
Due 31 July 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 31 July 1992
Resolved
Repair all alarms on inert gas system panel in cargo control room prior to arrival at next U.S. port.
Condition: Unknown
Due 31 July 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 31 July 1992
Resolved
Replace soft patch with a permanent repair on inert gas line to No. 6 starboard cargo (slop) tank prior to arrival at next U.S. port.
Condition: Unknown
Due 31 July 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 19 November 1987
Resolved
VESSEL ARPA WAS INOPERATIVE UPON ARRIVAL AT DELAWARE BAY DELAWARE.TELEX WASSENT THE SHIPPING AGENT (J.E.ASPEN).COTP WAS NOT NOTFIED A VIOLATION OF 33 CFR 164.53 PRIOR TO DEPARTING BIG STONE ANCHORAGE DELAWARE TO COSTAL EAGEL POINT TERMINAL WESTVILLE NJ.
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Deck/Cargo
Issued 19 November 1987
Resolved
ALL CARGO TANK HAD NO POSTIVE PRESSURE.SIX CARGO TANK WERE ABOVE 8%O2 LEVELPORT SLOPWAS19% STARBOARD SLOP WAS 14%,#2PORT10%,#2STARBOARD9.5%,#4STARBOAD18% AND#5STARBOARD17%.ALL TANK HAD POSTIVE PRESSURE AND BELOW 8%O2 LEVEL PRIOR TO DISCHARGE
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Deck/Cargo
Issued 19 November 1987
Resolved
MUST MAKE REPAIRS TO IG LINE #6 STARBOARD AT THE DECK FLANGE
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Deck/Cargo
Issued 14 July 1986
Resolved
REPAIR HIGH OXYGEN ALARM ON THE IGS PANEL IN THE CARGO CONTROL ROOM, DISPLAYS CONSTANT HIGH OXYGEN READING.
Condition: Unknown
Due 14 July 1986
Resolved 14 July 1986