Records from 1989 to 2002. Most recent: inspection, 13 December 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
13 December 2002
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1718416
14 September 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 293825
14 September 2001
Tank Vessel Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1074628
4 June 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 278569
9 March 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 38012
24 April 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 427951
6 July 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1129119
9 April 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 414766
23 December 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 398887
30 April 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 390718
31 January 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 387938
7 November 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 133758
9 February 1995
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1392164
1 December 1994
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1370961
12 January 1994
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1160923
5 November 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 362590
5 November 1993
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399932
25 August 1992
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1248318
23 August 1991
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1253400
17 July 1990
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 914327
14 June 1989
Certificate of Compliance · MARPOL Annex II Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 887060
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 13 December 2002
No resolution recorded
FLAME SCREENS ON PV VALVES NOT OF PROPER MESH SIZE. VESSEL HAD 20X20 MESH STAINLESS SCREEN BUT WAS NOT DOUBLED.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 January 2003 — due date passed with no resolution recorded
Deck/Cargo
Issued 9 April 1998
Resolved
COMPLETE REPAIRS TO #2 CARGO PUMP AND TEST EMERGENCY SHUTDOWN TO THE SATIFACTION OF THE CLASS SOCIETY. FAX SAT CLASS REPORT TO MORMS. DO NOT USE#2 PUMP UNTIL COMPLETED.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Construction/Loadline
Issued 31 January 1996
Resolved
PROVE PROPER OPERATION OF VESSEL'S OIL DISCHARGE MONITORING EQUIPMENT. TO BE OBSERVED BY CLASS SOCIETY AND APPROVAL TO BE FAXED TO MSU GALVESTON UPONTEST COMPLETION. TO BE DONE PRIOR TO VESSEL ARRIVING AT ITS NEXT U.S. PORTAFTER LOOP, LOUISIANA.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Navigation
Issued 31 January 1996
Resolved
PROVIDE ON BOARD AN OPERABLE AZIMUTH CIRCLE/ALIDADE (GYRO REPEATER) ON PORTBRIDGEWING TO READ IN COINCIDENCE WITH VESSEL'S MAIN GYROCOMPASS SYSTEM ANDALL ADJACENT REPEATERS. TO BE DONE PRIOR TO ARRIVAL AT NEXT U.S. PORT AFTER DEPARTURE FROM LOOP, LOUSISANA.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Lifesaving
Issued 1 December 1994
Resolved
UPDATE FIRE CONTROL & LIFE SAVING PLAN TO SHOW CHANGES IN STOWAGE OF EQUIPMENT AND THEIR LOCATION. SHOW PROOF OF APPROVAL BY FLAG STATE PRIOR TONEXT U.S. PORT.
Condition: Unknown
Due 1 December 1994
Resolved 1 December 1994
Fire Fighting
Issued 1 December 1994
Resolved
ENSURE PORTABLE EXTINGUISHERS ARE TESTED & INSPECTED TO THE SATISFACTION OFTHE ATTENDING U.S. COAST GUARD INSPECTOR.
Condition: Unknown
Due 1 December 1994
Resolved 1 December 1994
Navigation
Issued 5 November 1993
Resolved
UPDATE IN ACCURATE DEVIATION TABLE PRIOR TO RE-ENTRY U.S.
Condition: Unknown
Due 5 November 1993
Resolved 5 November 1993
Construction/Loadline
Issued 5 November 1993
Resolved
REPAIR INOPERATIVE SEGREGATED BALLAST MONITOR
Condition: Unknown
Due 5 November 1993
Resolved 5 November 1993
Deck/Cargo
Issued 14 June 1989
Resolved
INSTALL I. G. MAIN DECK LINE PRESSURE INDICATOR AT THE LOCATION OF THE PERSON IN CHARGE OF THE MAIN PROPULSION.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Deck/Cargo
Issued 14 June 1989
Resolved
INSTALL I. G. TEMP INDICATOR AT THE LOCATION OF PERSON IN CHARGE OF MAIN PROPULSION.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989