Records from 1987 to 2003. Most recent: inspection, 2 January 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
2 January 2003
Certificate of Compliance · Ballast Water Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1727360
22 September 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 294085
14 June 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 429698
14 June 1999
Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1408322
11 April 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 415024
11 April 1998
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 789897
9 April 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 402576
29 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1191855
7 August 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 381494
21 May 1994
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1457176
17 December 1992
Certificate of Compliance · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1137625
14 December 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 347753
14 December 1991
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 950233
26 October 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 340599
26 October 1990
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912395
7 November 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 326746
7 November 1988
MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1207389
28 February 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 314472
Navigation
Issued 22 September 2001
Resolved
NO ALARM TO SIGNAL THE AUTOPILOT IN ON WHEN MANUAL HELM COMMANDS ARE ATTEMPTED. TO BE COMPLETED PRIOR TO RETURNING TO U.S. WATERS AFTER NEXT FOREIGN PORT.
Condition: Unknown
Due 22 September 2002
Resolved 2 January 2003
Resolution: Alarm for the autopilot when in manual helm has been corrected and satisfactory to attending Coast Guard Inspector.
Navigation
Issued 22 September 2001
Resolved
NONFOLLOW STEERING NOT OPERATING. COMPLETED PRIOR TO RETURNING TO A US PORTFROM NEXT FOREIGN VOYAGE.
Condition: Unknown
Due 22 September 2002
Resolved 2 January 2003
Resolution: Nonfollow steering is operating and to the satisfaction of attending Coast Guard Inspector.
Navigation
Issued 22 September 2001
Resolved
10 CM RADAR IS INOPERABLE. MUST COMPLETE PRIOR TO DEPARTING MSO MORGAN CITY.
Condition: Unknown
Due 22 September 2002
Resolved 2 January 2003
Resolution: According to Tech report dated on 22SEP02, Radar is in operable condition. Visualy checked radar and was in working condition.
Deck/Cargo
Issued 7 August 1995
Resolved
PROVIDE OIL TRANSFER PROCEDURES ON BOARD PRIOR TO NEXT ENTRY INTO U.S. WATERS.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Navigation
Issued 7 August 1995
Resolved
REPAIR RUDDER ANGLE INDICATOR ON BRIDGE PRIOR TO NEXT ENTRY INTO U.S. WATERS TO THE SATISFACTION OF THE CLASSIFICATION SOCIETY.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Deck/Cargo
Issued 17 December 1992
Resolved
MAKE J. BOXES FOR CARGO PUMP BEARING TEMP. SENSORS EXPLOSION PROOF.
Condition: Unknown
Due 15 December 1993
Resolved 28 January 1993