R/V MARCUS G LANGSETH

R/V MARCUS G LANGSETH is a 1991 research vessel. The Coast Guard has recorded 49 inspections since 2002, most recently in January 2026, along with 36 deficiencies — 1 with no resolution recorded — and 2 operational controls.

Records from 2002 to 2026. Most recent: operational control imposed, 29 January 2026.

Built
1991
Last inspected
28 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9010137 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC6698
Flag
UNITED STATES
367059880
Maury page id
psix-22678

Inspections, by type

…with no type recorded8
Years with a record 18 calendar years (2002–2026)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)208.0 ft × 55.8 ft × 24.9 ft
Registered tonnagegross 3,834 / net 1,150
ITC dimensions (L × B × D)208.0 ft × 55.8 ft × 24.9 ft
ITC tonnagegross 3,834 / net 1,150
BuilderULSTEIN VERFT AS · Ulsteinvik, NORWAY · built 1991
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNew York, NY
Trade endorsementsRegistry
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itResearch Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3834 - Convention (Subpart B), Gross Ton
1150 - Convention (Subpart B), Net Ton
2646 - Displacement, Ton
1479 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC6698MMSI 367059880 · active · compulsorily equipped · granted 9 May 2025, expires 3 August 2035 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 49

28 January 2026 MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8287405
2 February 2025 Deficiency Check · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8074200
24 October 2024 Administrative Inspection
Administrative · Activities Europe · Activity 8023910
23 August 2024 Administrative Inspection
Administrative · Activities Europe · Activity 7987390
16 January 2024 ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7850282
4 January 2024 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7845363
15 November 2022 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7594984
1 November 2022 Annual Inspection · ACP Annual Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7587379
19 August 2022 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7538066
18 July 2022 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7509998
21 March 2022 Administrative Inspection · Appeal
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7449927
12 January 2022 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7379368
2 November 2021 Re-Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7341481
21 July 2021 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7263849
12 February 2021 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7134791
18 November 2020 ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7097316
30 September 2020 Administrative Inspection
Administrative · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7069082
23 September 2019 ACP Periodic Oversight · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6819230
6 September 2018 ACP Annual Oversight · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6524890
11 September 2017 ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6265492
9 May 2017 Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6142462
7 May 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6142617
18 November 2016 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6043950
15 August 2016 ACP COI Oversight · Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5973701
26 April 2016 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5862645
17 November 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5764934
22 October 2015 ACP Annual Oversight · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5748321
23 July 2015 ISM Oversight
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5197405
4 June 2014 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4879659
3 December 2010 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3919820
19 November 2010 Plan Review (Other than "T")
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3894841
4 October 2010 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3859044
23 March 2010 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3648560
20 January 2010 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3679379
15 December 2008 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3355063
6 October 2008 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3339853
22 January 2008 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3134265
5 November 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3094173
27 September 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3067284
27 September 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3067419
27 September 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3067689
14 September 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3067654
9 July 2007 Deadweight Survey · Reflagging & Initial Certification · MTSA/ISPS Verification · Inclining Experiment · Administrative Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2989956
13 June 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2960524
9 August 2006 Reflagging & Initial Certification
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2741711
1 February 2006 Permit to Proceed · MTSA/ISPS Verification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2577366
1 February 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2577669
15 June 2005 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2876042
8 March 2002 Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1492437

Deficiency record · 36

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 January 2026 Resolved
The emergency source of electrical power shall be sufficient to supply all services that are essential for safety in an emergency. The vessel's emergency generator breaker failed to automatically close when tested several times, troubleshooting and adjustments were made and the breaker operated correctly but voltage on the emergency switchboard indicated 200 volts. Make repairs and prove proper operation of emergency generator. Prior to vessel's departure. 74 SOLAS (97) II-I,Reg 43.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2026
Resolution: The generator breaker was replaced, tested all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2026 No resolution recorded
There must be ground detection for ship's service power systems and isolated power and lighting systems. Vessel's main and emergency switchboards 440V, 220V, and 120V ground detectors all show low resistance to ground and are in alarm conditions. Vessel's Chief Engineer demonstrated the faults do not go away when all circuits are isolated, indicating a failure of the detection system. Make electrical plan submittal to the Marine Safety Center (MSC) or Class Society for approval of new system design and installation. Submission due within 3 months and installation due at next dry dock. 06MAY26: received repair plan, extended due date until OCT2026.
Action required: 705 - Other - as specified
Due 31 October 2026
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 16 January 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The port and starboard engine order telegraph visual indicators on the bridge did not energize during the test of the system. SOLAS 74 (2020 Con. Ed.) I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2024
Resolved 26 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 16 January 2024 Resolved
Except as provided in paragraphs 5 and 6, life-saving appliances and arrangements required by this chapter shall be approved by the Administration. Rescue boat davit on board vessel does not have a Coast Guard Type Approval placard on the equipment required by the 2011 U.S. Supplement to International Conventions & Classification Society Rules for this ship enrolled in the ACP 17NOV11, section II-C SOLAS 74 (2020 Con. Ed.) III/4.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2024
Resolved 26 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 16 January 2024 Resolved
Except as provided in paragraphs 5 and 6, life-saving appliances and arrangements required by this chapter shall be approved by the Administration. Rescue boat davit winch on board vessel does not have a Coast Guard Type Approval placard on the equipment required by the 2011 U.S. Supplement to International Conventions & Classification Society Rules for this ship enrolled in the ACP 17NOV11, section II-C
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2024
Resolved 26 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 January 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The starboard life jacket storage bin is required to have 28 life jackets as placarded on the outside of the container, but only had 25 life jackets on station. SOLAS 74 (2020 Con. Ed.) III/20.2
Action required: 10 - Deficiency Rectified
Due 16 January 2024
Resolved 16 January 2024
Resolution: Located lifejackets and recounted all of them to ensure proper number were in the stowage bins.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 January 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. An unapproved modification in the engine room; an orange extension cord with an on/off switch was installed to the oil transfer controller panel. SOLAS 74 (2020 Con. Ed.) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 16 January 2024
Resolution: Electrician removed the orange extension cord from the panel in the presence of the USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 August 2022 Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery...must be at least equivalent to the standards established by the ABS Steel Vessel Rules. Starboard controllable pitch propeller (CPP) not functioning as designed. Restore starboard CPP to as-approved condition. Contract tugs of sufficient horsepower and bollard pull to assist with maneuvering into and around port until repair has been completed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 30 September 2020 Resolved
All vessels shall have efficient guard rails or bulwarks on decks and bridges. Vessel was involved in a collision that damaged the starboard bulwarks, freeing ports, fuel tank vent pipes. Conduct repairs to the satisfaction of ABS at next dry docking 30Sept21 , and provide class report upon completion to an attending USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 September 2021
Resolved 21 July 2021
Resolution: Received ABS report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 November 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the previsions of the present regulations. Emergency Generator high pressure fuel lines leaking diesel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 23 September 2019 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Spare parts and critical spare parts inventory is not accurate in NS5 Many parts onhand are not entered and critical spares are not identified. Recommend internal audit focused on spare parts inventory including critical spares required. ISM CODE 10.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 December 2019
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 11 September 2017 Resolved
Lithium chloride batteries, UNID# 3090, stored in the space labeled dry lab and bird lab on deck A. Batteries were found stored in a plastic box. Batteries must be stowed in accordance with 49 CFR 172.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Resolution: Stowage complies with 49 CFR 172.
Electrical › Electrical Distribution System (service) › Conductor
Issued 11 September 2017 Resolved
Dry lab found with multiple extension cords and daisy chains installed at electrical outlets. Surge protectors shall comply with Marine Safety Alert 03-13b and daisy chain extension cords shall be removed.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Resolution: Daisy chains removed and operator ordered surge protectors that comply with Marine Safety Alert 03-13b.
Construction/Loadline › Hull › Side Shell
Issued 17 November 2015 Resolved
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 December 2015
Resolved 20 November 2015
Resolution: Recieved class report of acceptable repairs.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 April 2010 Resolved
Replace missing light cover in the aft seismic lab. 46 CFR 111.75-20
Action required: 705 - Other - as specified
Due 5 May 2010
Resolved 26 April 2010
Resolution: Tube style light covers were installed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 5 April 2010 Resolved
Remove extension cord leading to drill press in machine shop and hard wire outlet. 46 CFR 111.60-13(b)(1)
Action required: 705 - Other - as specified
Due 5 May 2010
Resolved 23 April 2010
Resolution: A new outlet was installed and the extension cord was removed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 April 2010 Resolved
Install cover to properly protect exposed 220 wiring located behind dryers. 46 CFR 111.01-1
Action required: 705 - Other - as specified
Due 5 May 2010
Resolved 23 April 2010
Resolution: Covers were installed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 5 April 2010 Resolved
Remove extension cord and hard wire 110 volt electrical wiring leading to washing machines. 46 CFR 111.60-13(b)(1)
Action required: 705 - Other - as specified
Due 5 May 2010
Resolved 23 April 2010
Resolution: Washing machines are hard wired.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 April 2010 Resolved
Install electrical cover on junction box located in the elevator well on main deck. 46 CFR 111.01-1
Action required: 705 - Other - as specified
Due 5 May 2010
Resolved 23 April 2010
Resolution: All electical wiring iwo junction box was removed.
Construction/Loadline › Hull › Bottom Plating
Issued 5 April 2010 Resolved
Make permanent repairs to 10 inch doubler installed in the port aft peak tank in way of frame 00. To be completed no later than next drydock. NVIC 07-68
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 25 May 2011
Resolution: Received copy of ABS survey attesting to permanent repairs completed.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 5 April 2010 Resolved
Remove hold back devices and install a sign stating "door is to be kept closed while at sea" on doors leading to the forward dry stores space. 46 CFR 190.07-10
Action required: 705 - Other - as specified
Due 5 May 2010
Resolved 5 April 2010
Resolution: Hold backs removed and a sign was installed.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 5 April 2010 Resolved
Replace "fire block" in MCT in way of the main deck electrical closet. 46 CFR 190.07-10
Action required: 705 - Other - as specified
Due 5 May 2010
Resolved 5 April 2010
Resolution: Fire block was reinstalled.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 5 April 2010 Resolved
Adjust self closing door leading to the crew's mess so that door closes completely and latches. 46 CFR 190.07-10(c)(4)
Action required: 705 - Other - as specified
Due 5 May 2010
Resolved 23 April 2010
Resolution: Door closes and latches.
Communications › Radio Communications › EPIRB
Issued 5 April 2010 Resolved
Replace expired hydrostatic release on EPIRB located on the Starboard side of the Bridge deck. 46 CFR 199.510(b)
Action required: 705 - Other - as specified
Due 5 May 2010
Resolved 5 April 2010
Resolution: New Hydrostatic release installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 April 2010 Resolved
: Replace burned out element in stern light. 72 COLREGS
Action required: 705 - Other - as specified
Due 5 May 2010
Resolved 23 April 2010
Resolution: Stearn light element was replaced.
Accommodation/Occupational Safety › Ventilation › General
Issued 5 April 2010 Resolved
Replace or remove and blank off wasted ventilation ducting in the forward dry stores/laundry space
Action required: 705 - Other - as specified
Due 5 May 2010
Resolved 23 April 2010
Resolution: Wasted duckting has been removed and vent has been blanked off.
Electrical › Electrical Distribution System (service) › Cable
Issued 5 April 2010 Resolved
Disconnect power source to dead end cable in electrical trunk on "A" deck in way of "401" stairs. 46 CFR 111.01-1
Action required: 705 - Other - as specified
Due 5 May 2010
Resolved 23 April 2010
Resolution: Power has been secured to cable.
Construction/Loadline › Penetrations › Pipe Flange
Issued 5 April 2010 Resolved
Cap drain pipe in forward laundry. 46 CFR 190.03-1
Action required: 705 - Other - as specified
Due 5 May 2010
Resolved 23 April 2010
Resolution: Drain pipe has been capped.
Accommodation/Occupational Safety › Ventilation › General
Issued 21 November 2009 Resolved
Remove flexible ducting for the dryer vent and replace with hard metallic ducting in forward laundry. 46 CFR 190.05-3
Action required: 705 - Other - as specified
Due 5 May 2010
Resolved 23 April 2010
Resolution: Hard ducting has been installed.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 15 December 2008 Resolved
Submit design verification test procedures and periodic safety test procedures documents to the Coast Guard Marine Safety center for approval. Retain copies on board as required by 46 CFR 61.40-1 Complete prior to 01/24/09
Action required: 705 - Other - as specified
Due 21 November 2009
Resolved 9 October 2009
Resolution: PSTPs have been submitted and comments addressed.
Communications › Alarms/Indicators › Ballast Alarm
Issued 15 December 2008 Resolved
Submit ships fuel tank level indicating system plans to the Marine Safety Center for review and approval. 46 CFR 56.50-90 Complete prior to 02/16/09
Action required: 705 - Other - as specified
Due 11 November 2009
Resolved 9 October 2009
Resolution: Plans have been submitted and approved. System tested sat.
Communications › Alarms/Indicators › Ballast Alarm
Issued 15 December 2008 Resolved
Submit plans for the crew installed fuel tank overfill alarm panel to the Marine Safety Center for review. 46 CFR 189.45-1 Complete prior to 01/24/09
Action required: 705 - Other - as specified
Due 21 November 2009
Resolved 9 October 2009
Resolution: Plans have been submitted and approved, system tested sat.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 15 December 2008 Resolved
Submit plans to the Coast Guard Marine Safety Center for suitability of the windows in the watertight bulkhead between the science labs and comply with all Marine Safety Center requirements to the satisfaction of the attending Marine Inspector. 46 CFR 171.111/46 CFR 189.45-1 Complete prior to removing temporary covers or 02/16/09
Due 21 November 2009
Resolved 9 October 2009
Resolution: Plans have been submitted and approved, windows are scheduled to be inserted during the vessels upcoming DD.
Engineering › Steering Gear System › Feedback Unit
Issued 15 December 2008 Resolved
Complete on-going plan review process with the Marine Safety Center for the steering gear control system. Submit information requested in the attached letter serial number: E1-0701180 dated April 16, 2007. 46 CFR 189.45-1 Complete prior to 01/24/09
Action required: 705 - Other - as specified
Due 21 November 2009
Resolved 23 April 2010
Engineering › Sea-water System (primary cooling) › Valve
Issued 15 December 2008 Resolved
Replace any non-approved or un-identifiable sea valves with approved valves prior to completion of the vessels next dry-dock. Complete prior to 09/21/09
Action required: 705 - Other - as specified
Due 21 October 2009
Resolved 18 August 2009
Resolution: Vessel has added all of the sea valves to the next DD contract.
Documentation › Manuals/Policy Documentation
Issued 8 March 2002 Resolved
NO TRANSFER PROCEDURES WERE ONBOARD AS PER 33CFR155.720. LEGACY COMPONENT DESC: Transfer Procedures
Condition: Unknown
Action required: 703 - Prior to bunkering operations
Due 8 March 2002
Resolved 9 March 2002
Resolution: Vessel provided oil transfer procedures.