Records from 1984 to 2002. Most recent: inspection, 28 June 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Engineering › Sea-water System (primary cooling)
Issued 28 June 2002
Resolved
6/2802: Noted hole/wastage on bottom of Starboard side main engine seawater pump. Currently shored with piece of wood. Flag/Class to attest or recommend correction no later than 6/15/02. 6/29.02: Class approved temp. repairs. Permanent repairs now a condition of Class NLT 31JUL02. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2002
Resolved 29 June 2002
Resolution: Class report attested that a temporary repair was made with plug and plastic compound .
Fire Fighting › Means of Escape
Issued 28 June 2002
Resolved
Flag/Class to explain feasability of fire station located in very aft escape trunk of engine room. SOLAS 60/II
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 July 2002
Resolved 30 June 2002
Resolution: Class/DNV Report 08272 dtd 6/29/02 by "A. Das" attested to correction.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 28 June 2002
Resolved
Top of main engine crankcase has puddles of fuel, (3rd deck engine room). Clean prior to Main Engine start up/departure. LEGACY COMPONENT DESC: Crankcase
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2002
Resolution: Class report verified puddles of fuel cleaned up.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 28 June 2002
Resolved
Half or more of high pressure line covers to main engine holed or torn. Replace with new, no later 15Jul02, SOLAS 60/II LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Condition: Improper/Lack of Maintenance
Due 15 July 2002
Resolved 30 June 2002
Resolution: Class report attested the High Pressure lines being replaced.
Fire Fighting › Combustible Materials
Issued 28 June 2002
Resolved
Remove all open paint cans from steering room. SOLAS/60/II LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2002
Resolution: Class report verified paint cans removed from steering room..
Fire Fighting › Fixed Fire Detection System
Issued 28 June 2002
Resolved
Fire detection unit's inoperable in engineering space. Randomly tested 3 units w/negative results. SOLAS 60/II/61 LEGACY COMPONENT DESC: Flame Detectors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 June 2002
Resolution: Class report attested to the replacing of the Fire detection units in engineering spaces.
Fire Fighting › Structural Fire Protection - General
Issued 28 June 2002
Resolved
Repair/Replace fire doors to main engine control room. Class/Flag to attest to correction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2002
Resolved 30 June 2002
Resolution: Class report attested to the repaires to the Fire doors and made self closing.
Electrical › Lighting (service)
Issued 28 June 2002
Resolved
Replace all broken or missing light covers in engine spaces (including purifier room & main engine control). LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 15 July 2002
Resolved 30 June 2002
Resolution: Class report attested that the Missing light covers have been replaced.
Fire Fighting › Self-contained Breathing Apparatus
Issued 28 June 2002
Resolved
Supplied Air Breathing Apparatus non ready or operable condition. SOLAS 60/II
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2002
Resolution: Class report stated that the vessel has ordered Two new ABAs.
Lifesaving › Lifebuoys
Issued 28 June 2002
Resolved
Repair and or Replace (2) Life Ring buoys SOLAS 60/III
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2002
Resolution: Class report attested to the replacement of the old Life bouys.
Lifesaving › Lifeboat
Issued 28 June 2002
Resolved
Make repair to buoyant lifelines and reflective tape on lifeboats SOLAS 60/III LEGACY COMPONENT DESC: Handholds/Handrails
Condition: Improper/Lack of Maintenance
Due 15 July 2002
Resolved 30 June 2002
Resolution: Class report attested the replacement of the liflines and reflective tape on lifeboats.
Engineering › Steam System (main)
Issued 28 June 2002
Resolved
Make repair to leaking steam lines on main deck (forward of house & #2 hold). SOLAS 60/II LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 15 July 2002
Resolved 30 June 2002
Resolution: Class report attested to the repaired steam line.
Lifesaving › Rocket Parachute Flares
Issued 28 June 2002
Resolved
Vessel has only one good rocket flare, Replace expired flares. SOLAS 60/III
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2002
Resolution: Class report verified that the vessel has ordered new rocket flares to replace expired ones.
Fire Fighting
Issued 15 June 2001
Resolved
PROVIDE SERVICING REPORTS FOR PORTABLE FIRE EXTINGUISHERS, PRIOR TO DEPARTURE. SOLAS 60 II/57(D)
Condition: Unknown
Due 15 June 2001
Resolved 21 June 2001
Fire Fighting
Issued 15 June 2001
Resolved
PROVIDE SERVICING REPORT FOR FIXED CO2 FIRE EXTINGUISHING SYSTEM, PRIOR TO DEPARTURE. SOLAS 60 II/57(D)
Condition: Unknown
Due 15 June 2001
Resolved 21 June 2001
Electrical
Issued 15 June 2001
Resolved
INSTALL LIGHT COVERS IN SHIPS HOSPITAL, NOTED 2 COVERS TO BE MISSING. SOLAS60 II/27(A)
Condition: Unknown
Due 15 July 2001
Resolved 28 June 2002
Lifesaving
Issued 15 June 2001
Resolved
PROVIDE SERVICING REPORT FOR PORT AND STARBOARD AFT LIFERAFTS, PRIOR TO DEPARTURE. SOLAS 74 (AMENDED) III/19.8.1
Condition: Unknown
Due 15 June 2001
Resolved 21 June 2001
Documentation
Issued 15 June 2001
Resolved
PROVIDE NEW SAFETY RADIO, SAFETY CONSTRUCTION, AND SAFETY EQUIPMENT CERTIFICATE, OR EXTENSION FROM TURKISH GOVERNMENT PRIOR TO DEPARTURE. SOLAS74 (AMENDED) I/12
Condition: Unknown
Due 15 June 2001
Resolved 21 June 2001
Lifesaving
Issued 15 June 2001
Resolved
PROVIDE NEW SMOKE SIGNALS FOR LIFEBOATS PRIOR TO DEPARTURE. SOLAS 74 (AMENDED) III/30.3
Condition: Unknown
Due 15 June 2001
Resolved 21 June 2001
Construction/Loadline
Issued 15 June 2001
Resolved
PROVIDE LOADLNE MARKING ON STARBOARD SIDE WITH CONTRASTING COLOR. ILLC ANNEX I/9
Condition: Unknown
Due 15 July 2001
Resolved 28 June 2002
Engineering
Issued 19 March 2001
Resolved
REPAIR LEAKING STEAM LINE AT BOILER DECK OVERHEAD BY LADDER WITHIN 30 DAYS.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Engineering
Issued 19 March 2001
Resolved
NUMBER 3 SHIP SERVICE GENERATOR LEAKING COOLING WATER. REPAIR WITHIN 30 DAYS.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Engineering
Issued 19 March 2001
No resolution recorded
ENGINE COOLING PIPING SYSTEM JOINT BOLTS WASTED. REPLACE AT NEXT DRY DOCK.
Condition: Unknown
Due 1 April 2003 — due date passed with no resolution recorded
Navigation
Issued 19 March 2001
Resolved
STEERING FAILURE AUDIO ALARM INOPERABLE. REPAIR WITHIN 30 DAYS.
Condition: Unknown
Due 2 July 2001
Resolved 2 July 2001
Unknown
Issued 8 August 2000
Resolved
HYDRAULIC PIPING IN WAY OF #5 HOLD STARBOARD SIDE IS HOLED AT PIPE MOUNTING.
Condition: Unknown
Due 27 November 2000
Resolved 27 November 2000
Deck/Cargo
Issued 8 August 2000
Resolved
STEAM PIPING HOLED FORWARD OF #7 HOLD THAT SERVICES THE PORT MOORING WINCH.
Condition: Unknown
Due 27 November 2000
Resolved 27 November 2000
Construction/Loadline
Issued 8 August 2000
Resolved
AIR LINE FORWARD OF #7 HOLD UNSECURED PIPE CLAMPS WASTED.
Condition: Unknown
Due 27 November 2000
Resolved 27 November 2000
Construction/Loadline
Issued 8 August 2000
Resolved
CATWALK BETWEEN #7 AND #8 HOLD'S FORWARD SUPPORT WASTED.
Condition: Unknown
Due 27 November 2000
Resolved 27 November 2000
Construction/Loadline
Issued 8 August 2000
Resolved
CATWALK PLATING FORWARD OF #1 HOLD STARBOARD SIDE IS WASTED.
Condition: Unknown
Due 27 November 2000
Resolved 27 November 2000
Construction/Loadline
Issued 10 April 2000
Resolved
CO2 ROOM ESCAPE HATCH GASKET NOT WATER TIGHT.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Deck/Cargo
Issued 10 April 2000
Resolved
EVIDENCE OF MAIN DECK FRACTURE FOWARD PORT CORNER AND PORT AND STARBOARD AFT CORNERS OF CARGO HOLD #3. TO BE ADDRESSED BY CLASS SURVEYOR.
Condition: Unknown
Due 12 April 2000
Resolved 12 May 2000
Construction/Loadline
Issued 10 April 2000
Resolved
MAIN DECK FRACTURE APPROXIMATELY 18 INCHES ALONG THE WELDMENT FOWARD OF CARGO HOLD #05. TO BE ADDRESSED BY CLASS SURVEYOR.
Condition: Unknown
Due 12 April 2000
Resolved 27 April 2000
Accommodation/Occupational Safety
Issued 10 April 2000
Resolved
NO DOCUMENTATION OR PLACARD CERTIFYING MARINE SANITATION DEVICE.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Lifesaving
Issued 10 April 2000
Resolved
LIFE JACKETS IN ENGINE CONTROL ROOM MISSING LIGHTS.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Deck/Cargo
Issued 10 April 2000
Resolved
EVIDENCE OF FRACTURES AT STARBOARD FOWARD CORNER AND PORT AND STARBOARD AFTCORNER OF CARGO HOLD #7. TO BE ADDRESSED BY CLASS SURVEYOR.
Condition: Unknown
Due 12 April 2000
Resolved 12 May 2000
Deck/Cargo
Issued 10 April 2000
Resolved
EVIDENCE OF FRACTURE IN PORT UPPER WING BALLAST TANK IN CARGO HOLD #5._x001C_ TO BE ADDRESSED BY CLASS SURVEYOR.
Condition: Unknown
Due 12 April 2000
Resolved 12 May 2000
Accommodation/Occupational Safety
Issued 10 April 2000
Resolved
PORT SIDE RAILS AT HOLD NUMBERS 3,4,5,6,7 WASTED.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Unknown
Issued 10 April 2000
Resolved
NO EMERGENCY STEERING INSTRUCTIONS POSTED IN AFT STEERING.
Condition: Unknown
Due 11 May 2000
Resolved 27 April 2000
Deck/Cargo
Issued 10 April 2000
Resolved
STEAM LEAK ON SEVERLY WASTED ACCESS PLATE FOR AFT MOORING WINCH.
Condition: Unknown
Due 11 May 2000
Resolved 27 April 2000
Accommodation/Occupational Safety
Issued 10 April 2000
Resolved
AFT OF #09 HOLD CENTERLINE LADDER RAIL WASTED.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Lifesaving
Issued 10 April 2000
Resolved
PORT SIDE LIFEBOAT PLATFORM ONE SECTION COMPLETELY WASTED.
Condition: Unknown
Due 11 May 2000
Resolved 12 May 2000
Navigation
Issued 1 March 1999
Resolved
REPAIR/RENEW AS ORIGINAL AND PROVE THE PROPER OPERATION OF THE VESSEL'S RADIO DIRECTION FINDER, OR AS AN ALTERNATIVE, PROVIDE AN EXEMPTION CERTIFICATE FROM THE VESSEL'S CLASSIFICATION SOCIETY. SEE SOLAS 74 (amended) V/12(p)._x001C_
Condition: Unknown
Due 21 September 1999
Resolved 21 September 1999
Navigation
Issued 1 March 1999
Resolved
REPAIR/RENEW AS ORIGINAL VESSEL'S ARPA AND PROVE ITS PROPER OPERATION._x001C_ SEE SOLAS 74 (amended) II/12(j).
Condition: Unknown
Due 21 September 1999
Resolved 21 September 1999
Navigation
Issued 10 August 1989
Resolved
A VIO OF 33 CFR 164.38 IN THAT THE ARPA WAS NOT MAINTAINED IN AN OPERABLE CONDITION IN ACCORDANCE WITH 33 CFR 164.11(R).
Condition: Unknown
Due 10 August 1989
Resolved 10 August 1989
Navigation
Issued 10 August 1989
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 August 1989
Resolved 10 August 1989
Deck/Cargo
Issued 14 August 1986
Resolved
INERT GAS SYSTEM NOT OPERATING AS NECESSARY TO MAINTAIN AN INERT ATMOSHERE IN CARGO TANKS.
Condition: Unknown
Due 14 August 1986
Resolved 14 August 1986
Navigation
Issued 20 July 1984
Resolved
THE MOST RECENT COPY OF THE TIDE TABLES, OR ITS EQUIVALENT, AS REQUIRED BY 33 CFR 164.33(A)(2)(I) WAS NOT ON BOARD.
Condition: Unknown
Due 20 July 1984
Resolved 20 July 1984
Engineering
Issued 20 July 1984
Resolved
THE STANDARD DISCHARGE CONNECTION REQUIRED BY 33 CFR 155.430 WAS NOT ON BOARD THE VESSEL.
Condition: Unknown
Due 20 July 1984
Resolved 20 July 1984