MAURY USCG vessel records Sign in
← All vessels

AP PRIDE

AP PRIDE is a 1974 tank ship. The Coast Guard has recorded 11 inspections since 1985, most recently in February 2004, along with 18 deficiencies and 1 operational control.

Records from 1985 to 2004. Most recent: operational control imposed, 2 February 2004.

Built
1974
Last inspected
2 February 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7369091 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226832
Flag
DENMARK
—
Maury page id
psix-226832

Inspections, by type

…with no type recorded7
Years with a record 6 calendar years (1985–2004)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11759 - Regulatory (Subpart C or D), Net Ton
32004 - Dead Weight, Ton
19171 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

2 February 2004 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2000181
13 November 2003 Certificate of Compliance
Administrative · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1946846
2 March 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 287677
6 December 1987 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 320008
20 November 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 319669
20 November 1987 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1026771
20 November 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337484
11 August 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 310795
15 June 1986 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 309546
15 June 1986 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 991841
3 January 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 436975

Deficiency record · 18

Electrical › Lighting (service)
Issued 13 November 2003 Resolved
Numerous lights in engine room missing covers. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 24 November 2003
Resolved 3 February 2004
Resolution: CDO rcvdc class report
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 13 November 2003 Resolved
Unable to demonstrate proper emergency shutdown for the #4 cargo pump. Pump not to be used until proper operation is demonstrated to the satisfaction of Class Society surveyor. LEGACY COMPONENT DESC: Emergency Shut-down
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 3 February 2004
Resolution: CDO rcvdc class report
Documentation › Markings/Placards
Issued 13 November 2003 Resolved
No Discharge of oil placard posted in the engine room. LEGACY COMPONENT DESC: Oil Discharge Placard
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 24 November 2003
Resolved 3 February 2004
Resolution: CDO rcvdc class report
Engineering › Sea-water System (primary cooling)
Issued 13 November 2003 Resolved
Salt water cooling line to ship's # 1 and # 2 generators temporarily repaired with rubber hose & couplings. Complete permanent repairs. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 3 February 2004
Resolution: CDO rcvdc class report
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 13 November 2003 Resolved
Last service date on all portable fire ext. 16 SEPT 2001. Provide servicing report for all extinguishers or Flag state letter attesting to extension date.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 24 November 2003
Resolved 3 February 2004
Resolution: CDO rcvdc class report
Pollution Prevention/Response › Prevention Equipment
Issued 13 November 2003 Resolved
Type II MSD was missing manufacturers plate verifying MSD meets all requirements of 33 CFR 159.55. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 26 November 2003
Resolved 3 February 2004
Resolution: CDO rcvdc class report
Electrical › Lighting (service)
Issued 13 November 2003 Resolved
Protective light covers were cracked in Cargo Pump Room. All lights have double lenses and the interior lenses were cracked. No exterior lenses were cracked. Must replace all lenses as per SOLAS 74 II-2, REG 54.2.2 LEGACY COMPONENT DESC: Lighting Fixture
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 26 November 2003
Resolved 3 February 2004
Resolution: CDO rcvd class report
Lifesaving › Buoyant Apparatus
Issued 13 November 2003 Resolved
Several Liferings with wasted grablines and damage were observed. Replace all apparatus to include MOB liferings on bridgewings as per SOLAS 74, Chap. III, Reg 19.2 LEGACY COMPONENT DESC: Liferings
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 26 November 2003
Resolved 3 February 2004
Resolution: CDO rcvd class report
Accommodation/Occupational Safety › Occupational Safety
Issued 13 November 2003 Resolved
Several light covers missing and/or improperly installed in reefers. Bare light bulbs and wiring are posing a shock hazard due to low ceiling height. Provide protective covers and permanently install all light fixtures in reefer/freezer spaces. LEGACY COMPONENT DESC: Receptacle Outlet
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 26 November 2003
Resolved 3 February 2004
Resolution: CDO rcvd class report
Documentation › Markings/Placards
Issued 13 November 2003 Resolved
Missing placard containing operating procedures, safety precautions and warnings pertinent to MSD device. Provide placard with all the requirements of 33 CFR 159.59
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 26 November 2003
Resolved 3 February 2004
Resolution: CDO rcvd class report
Construction/Loadline
Issued 2 March 2001 Resolved
The Loadlines and draft marks on either side of the vessel were not paintedin clearly contrasting colors.
Condition: Unknown
Due 4 March 2001
Resolved 5 March 2001
Fire Fighting
Issued 2 March 2001 Resolved
The exhaust pipe on the Emergency Firepump (EFP) failed during startup of the EFP. The exhaust pipe ruptured and caused exhaust fumes to leaki into the EFP room.
Condition: Unknown
Due 4 March 2001
Resolved 5 March 2001
Deck/Cargo
Issued 20 November 1987 Resolved
CARGO DISCHARGE MONITOR INOPERATIVE.
Condition: Unknown
Due 20 November 1987
Resolved 20 November 1987
Navigation
Issued 20 November 1987 Resolved
SECONDARY RADAR NOT OPERATING PROPERLY.
Condition: Unknown
Due 20 November 1987
Resolved 20 November 1987
Accommodation/Occupational Safety
Issued 20 November 1987 Resolved
CHEMICAL FOR MSD NOT ONBOARD. RESTRICTED TO HOLDING TANK UNTIL CHEMICALRRRRRRRRRD IN U.S. WATERS.
Condition: Unknown
Due 20 November 1987
Resolved 20 November 1987
Construction/Loadline
Issued 20 November 1987 Resolved
STARBOARD PUMPROOM HATCH GASKET REQUIRES REPLACEMENT, PRIOR TO ENTERING NEXT U.S. PORT.
Condition: Unknown
Due 20 November 1987
Resolved 20 November 1987
Navigation
Issued 15 June 1986 Resolved
33 CFR 164.33(A)(2)(II) THE VESSEL DID NOT HAVE ON BOARD A CURRENTLY CORRECTED COPY OF, OR APPLICABLE CURRENTLY CORRECTED EXTRACT FROM, THE COAST GUARD LIGHT LIST FOR THE AREA TO BE TRANSITED (BOSTON HARBOR AND APPROACHES). THE VESSEL HAD NO LIGHT LIST ABOARD.
Condition: Unknown
Due 15 June 1986
Resolved 15 June 1986
Navigation
Issued 15 June 1986 Resolved
PROVIDE COAST GUARD LIGHT LIST.
Condition: Unknown
Due 15 June 1986
Resolved 15 June 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.