Records from 1985 to 1999. Most recent: inspection, 11 August 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
11 August 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 431425
28 April 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 415299
22 January 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 399565
19 August 1992
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 352697
28 November 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 327033
6 May 1988
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 323157
7 July 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 317213
14 January 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 299712
Deck/Cargo
Issued 11 August 1999
Resolved
NUMEROUS HYDRAULIC LINES AND VALVES ON MAIN DECK IN NEED OF MAINTENANCE/REPAIR.
Condition: Unknown
Due 16 August 1999
Resolved 20 August 1999
Fire Fighting
Issued 11 August 1999
Resolved
EMERGENCY FIRE PUMP CAN NOT PROVIDE PRESSURE TO MAIN DECK.
Condition: Unknown
Due 16 August 1999
Resolved 20 August 1999
Electrical
Issued 11 August 1999
Resolved
#3 GENERATOR AUTOMATIC VALVE HAS STEADY DRIP OF OIL INTERMITTANTLY.
Condition: Unknown
Due 16 August 1999
Resolved 20 August 1999
Lifesaving
Issued 11 August 1999
Resolved
[name withheld] TO DEMONSTRATE UNDERSTANDING OF ISM CODE AND SAFETY MANAGEMENT SYSTEM.
Condition: Unknown
Due 16 August 1999
Resolved 20 August 1999
Documentation
Issued 11 August 1999
Resolved
SHIP'S SAFETY MANAGEMENT CERTIFICATE ISSUED BEFORE THE COMPANY'S DOCUMENT OF COMPLIANCE.
Condition: Unknown
Due 16 August 1999
Resolved 20 August 1999
Deck/Cargo
Issued 11 August 1999
Resolved
SEVERE WASTAGE OF HYDRAULIC LINE PORT SIDE BETWEEN #1 AND #2 HOLDS. PIPE RUPTURED SPRAYING HYDRAULIC OIL ON DECK.
Condition: Unknown
Due 16 August 1999
Resolved 20 August 1999
Electrical
Issued 11 August 1999
Resolved
CONDUIT LEADING TO 220V OUTLET PORT SIDE IWO #1 HOLD SEVERELY WASTED.
Condition: Unknown
Due 16 August 1999
Resolved 20 August 1999
Engineering
Issued 11 August 1999
Resolved
PISTON COOLING HEAT EXCHANGER SALT WATER DISCHARGE LINE HAS PIN HOLE LEAK AT BEND IN PIPE.
Condition: Unknown
Due 16 August 1999
Resolved 20 August 1999
Accommodation/Occupational Safety
Issued 11 August 1999
Resolved
DETERIORATED CAT WALK BETWEEN 35 AND #6 HOLDS PORT SIDE.
Condition: Unknown
Due 16 August 1999
Resolved 20 August 1999
Deck/Cargo
Issued 11 August 1999
Resolved
#7 HOLD PORT SIDE HYDRAULIC TURNING GEAR MECHANISM TO OPEN HATCH DRIPS OIL CONSTANTLY INTO COFFERDAM.
Condition: Unknown
Due 16 August 1999
Resolved 20 August 1999
Navigation
Issued 11 August 1999
Resolved
CREW TOOK OVER 30 MINUTES TO DEMONSTRATE THE EMERGENCY STEERING PROCEDURES.
Condition: Unknown
Due 16 August 1999
Resolved 20 August 1999
Navigation
Issued 7 July 1987
Resolved
33 CFR 164.35(K) NO BLOCK DIAGRAM ONBOARD.
Condition: Unknown
Due 7 July 1987
Resolved 7 July 1987