Records from 1984 to 2003. Most recent: inspection, 21 February 2003.
Inspection history · 26
21 February 2003
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1747502
21 February 2003
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1747536
19 February 2003
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1747428
17 December 2002
MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1719881
23 July 2002
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1650998
13 February 2002
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1485870
12 February 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1486198
5 November 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 295314
19 January 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 285968
19 January 2001
Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1471591
18 January 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 273852
15 October 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 728623
27 September 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 36798
24 September 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 182272
23 September 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 420529
2 September 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 48990
17 August 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 419325
6 July 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 417565
3 October 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 408644
17 June 1997
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 404753
25 May 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 440828
9 August 1996
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 394736
17 June 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 392378
17 June 1996
Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1424243
12 August 1987
Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1336759
28 October 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 298599
Documentation › Logs/Records › Oil Record Book
Issued 19 February 2003
Resolved
Oil record book part 1 not being maintained as per guidance contained in MARPOL annex 1 for machinery book. LOU for 27,500 required and recieved for follow-up MV case.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2003
Resolved 21 February 2003
Resolution: LOU Received this date.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 19 February 2003
Resolved
Sewerage holding tank found lined up for overboard discharge of untreated sewerage in the port of NY. Letter of warning issued to vessel on the spot and crew corrected valve misalignement.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 February 2003
Resolved 19 February 2003
Resolution: Corrected on the spot, LOW issued this date for same.
Fire Fighting › Firemans Outfit › Gloves
Issued 19 February 2003
Resolved
Provide 2 pairs of fire suit gloves to complete the required 4 outfits on board the vessel prior to departing the port of NY.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2003
Resolved 21 February 2003
Resolution: Done this date.
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 19 February 2003
Resolved
Ch Eng Liberian license found missing. Renew or get a new Chief prior to departing the port of NY.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2003
Resolved 21 February 2003
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Personnel › Certificates/Documents/Licenses
Issued 19 February 2003
Resolved
3rd Mate's Liberian license missing and individual has no idea where his Phillipine Mate's lilcense is. Renew or get dispensation from Liberian consulate prior to departing the port of NY. LEGACY COMPONENT DESC: License, Third Mate
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2003
Resolved 21 February 2003
Resolution: Recieved documentation from Liberia showing a valid license this date.
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 16 December 2002
Resolved
Rear wall found badly distorted and overheated with fire watch in place while boiler on line. SOALS detention issued and boiler secured till repairs conducted and attested to by NKK. LEGACY COMPONENT DESC: Outer Casing
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 20 December 2002
Resolution: NKK Report received imposing condition of class to be permanently corrected prior to January 6, 2003.
Navigation › Piloting/Steering
Issued 16 December 2002
Resolved
Gyro compass not installed and non functional. Repair prior to departing the port of NY to satisfcation of NKK. LEGACY COMPONENT DESC: Gyro Compass
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 20 December 2002
Resolution: NKK Report received attesting to permanent repairs found satisfactory this date.
Deck/Cargo › Ballast
Issued 16 December 2002
Resolved
All SBTvent flame screens fouled with paint and ineffective. LEGACY COMPONENT DESC: Segregated Ballast Tank
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 20 December 2002
Resolution: NKK Report received attesting to permanent repairs found satisfactory this date.
Deck/Cargo › Vapor Control Systems
Issued 16 December 2002
Resolved
Mast riser isolation valves inoperative and non functional allowing cargo vapors and IG vapors to vent while at terminal. Repair prior to further cargo operations. LEGACY COMPONENT DESC: Manual Isolation Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 20 December 2002
Resolution: NKK Report received imposing condition of class to be permanently corrected prior to January 6, 2003.
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 16 December 2002
Resolved
Ship's air conditioning system not operational and vessel is intending to transit to tropics. Must demonstrate proper operation prior to departing the port of NY. LEGACY COMPONENT DESC: Inoperative
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 December 2002
Resolved 20 December 2002
Resolution: NKK Report received attesting to permanent repairs found satisfactory this date.
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 16 December 2002
Resolved
Ship's vegetable locker has ineffective refrigeration in use that lead to rotten vegetables on the shelves within the vegetable unit. Also man locked in reefer alarm non functional in veg and meat lockers. LEGACY COMPONENT DESC: Inoperative
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 December 2002
Resolved 20 December 2002
Resolution: NKK Report received attesting to permanent repairs found satisfactory this date.
Engineering › Steam Turbine (auxiliary)
Issued 16 December 2002
Resolved
Turbo generator casing / throttle block found blowing excessive steam while on line. Identify case of steam leaks and repair to satisfaction of NKK. LEGACY COMPONENT DESC: Casing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 20 December 2002
Resolution: NKK Report received imposing condition of class to be permanently corrected prior to January 6, 2003.
Operations/Management › Drills/Instruction
Issued 16 December 2002
Resolved
Safety orientation and indoctrination of new crew members suspected of not effectively managed IAW the vessels SMS. Provide documentation of effective use of SMS to external auditor prior to departing port of NY. LEGACY COMPONENT DESC: Safety Orientation
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 20 December 2002
Resolution: ABS conducted an external audit and provided a satisfactory report at the conclusioin attesting to completion of same.
Operations/Management › Casualty Reporting/Post-Casualty Actions
Issued 16 December 2002
Resolved
Documentation and proof of effective maintenance of vessel IAW approved SMS lacking and unable to be provided. Demonstrate effective use and implementation of SMS to external auditor prior to departing the port of NY. LEGACY COMPONENT DESC: Report of Potential Vessel Casualty
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 20 December 2002
Resolution: ABS conducted an external audit and provided a satisfactory report at the conclusioin attesting to completion of same.
Accommodation/Occupational Safety › Occupational Safety
Issued 16 December 2002
Resolved
Railing on accomodation ladder broken at base of stanchion and needs to be rewelded. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 20 December 2002
Resolution: NKK Report received imposing condition of class to be permanently corrected prior to January 6, 2003.
Fire Fighting › Fire Hoses
Issued 16 December 2002
Resolved
Fire hose next to engine control room door bursted. Replace it ! LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 20 December 2002
Resolution: NKK Report received attesting to permanent repairs found satisfactory this date.
Fire Fighting › Structural - A Class Divisions
Issued 16 December 2002
Resolved
Fire gasket on main deck door to stair tower missing. Replace it ! LEGACY COMPONENT DESC: Bulkheads - Stairways
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 20 December 2002
Resolution: NKK Report received attesting to permanent repairs found satisfactory this date.
Fire Fighting › Fire Pumps
Issued 16 December 2002
Resolved
Main fire pump gauges missing and inoperative. Replace them ! LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 20 December 2002
Resolution: NKK Report received attesting to permanent repairs found satisfactory this date.
Documentation › Certificates/Documents
Issued 13 February 2002
Resolved
Have NKK class surveyor correct improper MARPOL double hull phase out date prior to departing the port of NY on vessel's IOPP form B supplement. LEGACY COMPONENT DESC: IOPP Certificate
Action required: 17 - Rectify deficiencies prior to departure
Due 13 February 2002
Resolved 27 February 2002
Resolution: Received satisfactory class survey from NKK.
Pollution Prevention/Response
Issued 13 February 2002
Resolved
Repair machinery space OWS to automatically operate if 15 PPM alarm condition is exceeded as required by vessel's IOPP certificate form B supplement to satisfaction of an attending NKK surveyor prior to departing the Port of NY. LEGACY COMPONENT DESC: OILY WATER SEPARATOR(15PPM)
Due 13 February 2002
Resolved 27 February 2002
Resolution: Received class survey report from NKK.
Lifesaving
Issued 13 February 2002
Resolved
Renew the fwd liferaft hydrostatic release unit that is currently expired OR!! remove it from the installation and fax class survey report attesting to proper installation of same prior to departing the port of NY. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Due 13 February 2002
Resolved 27 February 2002
Resolution: Received class survey report from NKK.
Lifesaving
Issued 13 February 2002
Resolved
Repair broken hand crank starter for port lifeboat engine prior to departing port of NY to satisfaction of class surveyor (NKK) LEGACY COMPONENT DESC: Propulsion Engine
Due 13 February 2002
Resolved 27 February 2002
Resolution: Received class survey report from NKK.
Lifesaving
Issued 13 February 2002
Resolved
Repair lube oil leak on port lifeboat engine to satisfaction of NKK surveyor prior to departing port of NY. LEGACY COMPONENT DESC: Propulsion Engine
Due 13 February 2002
Resolved 27 February 2002
Resolution: Received class survey report from NKK.
Navigation
Issued 13 February 2002
Resolved
Procure a line throwing apparatus to replace the missing unit for nav bridge equipment prior to departing the port of NY.
Due 13 February 2002
Resolved 27 February 2002
Resolution: Received class survey report from NKK.
Deck/Cargo
Issued 23 September 1998
Resolved
Vessel missing Vapor Control Approval. Vessel may not use vapor control system in U.S. waters.
Condition: Unknown
Due 23 September 1998
Resolved 25 April 2002
Resolution: VESSEL MAY TRANSFER CARGOES THAT DO NOT REQUIRE VRS.
Deck/Cargo
Issued 6 July 1998
Resolved
Provide pin for vapor control flange. (missing)
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Documentation
Issued 17 June 1996
Resolved
Provide a vessel response plan (VRP) approved by the U.S. Coast Guard as per title 33 CFR 155 Subpart D. This item must be corrected prior to next cargo transfer in U.S. waters and next vessel entry into U.S. waters.
Condition: Unknown
Due 26 August 1996
Resolved 26 August 1996
Deck/Cargo
Issued 17 June 1996
Resolved
Install an overfill device, independent of the tank gauging system, on eachcargo tank as per title 33 CFR 155.480. This item must be corrected prior to next time vessel loads oil or oil residue as cargo in U.S. waters.
Condition: Unknown
Due 20 June 1997
Resolved 20 June 1997
Navigation
Issued 28 October 1984
Resolved
USCG LIGHT LIST VOL. III AND NOS COAST PILOT VOL. 7 INSUFFICIENTLY CORRECTED.
Condition: Unknown
Due 28 October 1984
Resolved 28 October 1984