MAURY USCG vessel records Sign in
← All vessels

DENEB

DENEB is a 1981 freight ship. The Coast Guard has recorded 12 inspections since 1986, most recently in June 2004, along with 6 deficiencies.

Records from 1986 to 2004. Most recent: inspection, 2 June 2004.

Built
1981
Last inspected
2 June 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8012841 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226882
Flag
DENMARK
—
Maury page id
psix-226882

Inspections, by type

…with no type recorded9
Years with a record 9 calendar years (1986–2004)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it878 - Convention (Subpart B), Net Ton
1166 - Convention (Subpart B), Gross Ton
2099 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 12

2 June 2004 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2086661
5 March 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2020504
22 March 2003 In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1780401
21 January 2003 Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1732876
24 August 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 419581
26 June 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 392712
14 June 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 458156
21 December 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 355204
11 June 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 337724
11 December 1987 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 320645
18 November 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 312895
16 January 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 306371

Deficiency record · 6

Deck/Cargo › Holds/Tanks
Issued 22 March 2003 Resolved
Repair leaking cargo hatch piping to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2003
Resolution: Cargo hatch piping repaired to the satisfaction of Class.
Fire Fighting › Emergency Fire Pumps
Issued 22 March 2003 Resolved
Repair emergency fire pump to the satisfaction of Class or have Class approve the portable one on board as an acceptable replacement.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2003
Resolution: Emergency fire pump was repaired to the satisfaction of Class.
Documentation
Issued 26 June 1996 Resolved
Vessel has no oil pollution placards posted.
Condition: Unknown
Due 24 August 1998
Resolved 24 August 1998
Documentation
Issued 11 December 1987 Resolved
A VIO OF 33 CFR 155.450 IN THAT THE VSL DID NOT HAVE O/B A DISCHARGE OF OILPROHIBITED PLACARD POSTED IN EITHER EACH MACHINERY SPACE OR AT THE BILGE AND BALLAST PUMP CONTROL STATION.
Condition: Unknown
Due 11 December 1987
Resolved 11 December 1987
Engineering
Issued 16 January 1986 Resolved
VESSEL FAILED TO HAVE A MINIUM NUMBER OF FOUR BOLTS IN BUNKERING CONNECTIONIAW 33 CFR 156.130(A)(2).
Condition: Unknown
Due 16 January 1986
Resolved 16 January 1986
Documentation
Issued 16 January 1986 Resolved
VESSEL FAILED TO HAVE ONBOARD A DISCHARGE OF OIL PROHIBITED PLACARD IAW 33 CFR 155.450(A).
Condition: Unknown
Due 21 December 1992
Resolved 21 December 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.