MAURY USCG vessel records Sign in
← All vessels

LARYMNA

LARYMNA is a 1983 freight ship. The Coast Guard has recorded 28 inspections since 1987, most recently in March 2005, along with 43 deficiencies and 3 operational controls.

Records from 1987 to 2005. Most recent: inspection, 17 March 2005.

Built
1983
Last inspected
17 March 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8018261 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226940
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-226940

Inspections, by type

…with no type recorded24
Years with a record 12 calendar years (1987–2005)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it13149 - Regulatory (Subpart C or D), Net Ton
23519 - Regulatory (Subpart C or D), Gross Ton
38973 - Dead Weight, Ton
49429 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

17 March 2005 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2311631
23 June 2003 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1824885
27 January 2002 Annual Inspection · In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1481636
16 June 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 279018
14 June 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 278943
9 April 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 276683
30 March 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 276332
31 July 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 430985
4 October 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 421093
22 February 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 412691
15 January 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 203839
15 January 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 399225
15 January 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 756878
26 December 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 398827
22 November 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 397548
22 August 1996 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1087712
27 December 1995 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 719342
4 December 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 702297
10 November 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 117603
10 November 1995 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 384672
29 August 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 382063
2 October 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 370934
22 June 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 702298
16 May 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 366864
16 May 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 367496
16 May 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 367777
16 February 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 523042
18 August 1987 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 317956

Deficiency record · 43

Navigation › Collision/Grounding Avoidance
Issued 27 January 2002 Resolved
Secondary radar inoperable.
Action required: 705 - Other - as specified
Due 27 January 2002
Resolved 27 January 2002
Resolution: Received satisfactory tech report (over-current protection tripped).
Lifesaving
Issued 30 March 2000 Resolved
Remove combustible stores located in crew cabin No. 526-RELEVE-1. _x001C_ SOLAS II-2/42.
Condition: Unknown
Due 31 March 2000
Resolved 3 April 2000
Engineering
Issued 30 March 2000 Resolved
Ensure the bunker line is hydrostatically tested to 1.5 times the MAWP prior to bunkering in U.S. waters._x001C_ 33 CFR 156.170.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Construction/Loadline
Issued 30 March 2000 Resolved
Repair forward joiner bulkhead doors, port and starboard, main deck. MSM Vol. II Chp. 6.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Construction/Loadline
Issued 30 March 2000 Resolved
Replace weathertight door, starboard 02 deck._x001C_ ILLC 66.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Accommodation/Occupational Safety
Issued 30 March 2000 Resolved
Repair condensate drain on aft A/C unit. MSM Vol. II Chp. 6.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Engineering
Issued 30 March 2000 Resolved
Provide closure devices for F/O vent containment._x001C_ 33 CFR 155.320.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Fire Fighting
Issued 30 March 2000 Resolved
Replace latches on fire boxes 2,3,5,7,9,11 and 13._x001C_ SOLAS II-2/21._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Construction/Loadline
Issued 30 March 2000 Resolved
Repair joiner bulkhead in deck workshop._x001C_ SOLAS II-2/43.1.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Accommodation/Occupational Safety
Issued 30 March 2000 Resolved
Replace overhead panel and vent screen in W/C #504._x001C_ SOLAS II-2/43.1.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Electrical
Issued 30 March 2000 Resolved
Remove dead end electrical cable from W/C 504._x001C_ SOLAS II-1/45.5.6.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Electrical
Issued 30 March 2000 Resolved
Replace cover on electrical recepticle, forcastle, port side._x001C_ SOLAS II-1/45.5.5.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Fire Fighting
Issued 30 March 2000 Resolved
Make permanent repairs to fire screen doors on uppper aft engine room and aft passage way._x001C_ SOLAS II-2/42.4.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Navigation
Issued 30 March 2000 Resolved
Repair echo sounding device continuous recorder._x001C_ 33 CFR 164.35.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Fire Fighting
Issued 30 March 2000 Resolved
Repair broken glass on fire hose station (box) #25._x001C_ SOLAS II-2/21.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Navigation
Issued 31 July 1999 Resolved
Repair the echo depth sounder as original prior to departure._x001C_ 33 C.F.R. 164.33
Condition: Unknown
Due 31 August 1999
Resolved 11 August 1999
Fire Fighting
Issued 31 July 1999 Resolved
Properly repair fire doors in engine room. Currently several fire doors_x001C_ are not self closing. Make permanent repairs prior to next U.S. port. Solas 74 II- 2/23.
Condition: Unknown
Due 9 April 2000
Resolved 9 April 2000
Fire Fighting
Issued 22 February 1998 Resolved
Unsatisfactory performance by crew on fire drill.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Lifesaving
Issued 22 February 1998 Resolved
Unsatisfactory performance by crew on lifeboat drill.
Condition: Unknown
Due 9 March 1998
Resolved 9 March 1998
Electrical
Issued 15 January 1997 Resolved
Provide Class society report on the functionabilty of #2 SSG lubo Cooler. Cooler leaked causing a oil spill and sheen.
Condition: Unknown
Due 21 January 1997
Resolved 24 January 1997
Engineering
Issued 26 December 1996 Resolved
VESSEL DID NOT HAVE RECORD OF MOST RECENT TEST AND RESULTS OF TRANSFER LINES FOR BUNKER STATIONS.
Condition: Unknown
Due 26 December 1996
Resolved 26 December 1996
Deck/Cargo
Issued 26 December 1996 Resolved
HYDRAULIC LINES ON CARGO HATCH COVER MACHINERY FOR CARGO HOLDS # 1,2,4 AND_x001C_5 LEAKED AT JOINTS. LIFTING RAMS FOR CARGO HOLDS 1 AND 5 ALSO LEAKED AROUNDSEALS.
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Electrical
Issued 22 November 1996 Resolved
MAINTAIN PROTECTIVE GLOBES AND GUARDS ON LIGHTING FIXTURES THROUGHOUT VESSEL._x001C_
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Engineering
Issued 10 November 1995 Resolved
VESSELS FUEL OIL CONTAINMENT FOR VENTS AND BUNKERING STATIONS HAD NO DRAIN PLUG TO PUT IN DRAIN.
Condition: Unknown
Due 12 November 1995
Resolved 26 December 1995
Lifesaving
Issued 10 November 1995 Resolved
VESSEL HAD NO BACKWASH BALL ON BOTTOM OF BOTH LIFEBOATS.
Condition: Unknown
Due 12 November 1995
Resolved 26 December 1995
Deck/Cargo
Issued 10 November 1995 Resolved
VESSEL DID NOT HAVE FLAME SCREENS ON ANY ITS APPROXIMATELY 4 FUEL VENTS ABOVE DECK.
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Navigation
Issued 10 November 1995 Resolved
VESSEL TRANSITED TO DIABLO SERVICES, PITTSBURG, CA. WITHOUT CHARTS 18659 AND 18661.
Condition: Unknown
Due 12 November 1995
Resolved 16 November 1995
Lifesaving
Issued 10 November 1995 Resolved
VESSELS LIFE BOUYS ON BOTH BRIDGE WINGS WERE NOT AT LEAST FOUR KILOGRAMS.
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Lifesaving
Issued 10 November 1995 Resolved
VESSELS WATER TANKS IN BOTH LIFE BOATS HAD NON-WORKING CAPS TO SEAL TANKS._x001C_WATER WOULD NOT BE ABLE TO STAY SAFE TO DRINK WITH CURRENT CAPS.
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Lifesaving
Issued 10 November 1995 Resolved
VESSEL HAD A LIGHT ON A LIFE BOUY THAT WAS NOT OPERATIONAL.
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Fire Fighting
Issued 29 August 1995 Resolved
Correct excessive leaking around connection points at hydrant and nozzle for fire hose located on upper forecastle._x001C_ _x001C_ SOLAS CH II-2, REG 4 (6.1)_x001C_
Condition: Unknown
Due 31 August 1995
Resolved 1 September 1995
Navigation
Issued 29 August 1995 Resolved
Provide a copy of the inland navigation rules prior to departure from port.
Condition: Unknown
Due 31 August 1995
Resolved 1 September 1995
Fire Fighting
Issued 29 August 1995 Resolved
Repair gauge for CO2 system in the paint locker. (face and needle missing)prior to departure from port._x001C_ _x001C_ SOLAS CH II-1, REG 26 (1)
Condition: Unknown
Due 31 August 1995
Resolved 1 September 1995
Fire Fighting
Issued 29 August 1995 Resolved
Make the fire door to the emergency steering/fire pump room from the engineroom gas tight. (Door currently has holes from previous installations whichhave been removed.)_x001C_ SOLAS CH II-2, REG 47 (1)
Condition: Unknown
Due 31 August 1995
Resolved 1 September 1995
Engineering
Issued 29 August 1995 Resolved
Make permanent repairs and provide class report on 1) patched M/E L/O cooler S/W discharge pipe at both ends 2) patched air conditioner S/W cooling pipe connecting #1 and #2 pumps, prior to next U.S port call._x001C_ SOLAS CH II-1, REG 26 (1)
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Fire Fighting
Issued 29 August 1995 Resolved
Make permanent repairs to leaking fire main couplings located on starboard side at #3 and #4 cargo holds aft of the steps.
Condition: Unknown
Due 31 August 1995
Resolved 1 September 1995
Engineering
Issued 29 August 1995 Resolved
Remove excessive oil in containment area around feed water tank for boiler and correct blockage to overflow line prior to departure from port._x001C_ _x001C_ SOLAS CH II-1, REG 26 (1)
Condition: Unknown
Due 31 August 1995
Resolved 1 September 1995
Fire Fighting
Issued 29 August 1995 Resolved
Make permanent repairs to fire hose in fire box #33 in the engine room which has a gash below the nozzle approximately one quarter the width of the hose, prior to departure from port._x001C_ SOLAS CH II-2, REG 21
Condition: Unknown
Due 31 August 1995
Resolved 1 September 1995
Fire Fighting
Issued 29 August 1995 Resolved
Remove the hold back devices to the fire doors leading to the emergency steering/fire pump compartments from the engine room and the provision stores passageway prior to departure from port._x001C_ SOLAS CH II-2, REG 47 (2)
Condition: Unknown
Due 31 August 1995
Resolved 1 September 1995
Construction/Loadline
Issued 29 August 1995 Resolved
Prove proper operation of bilge pump for emergency fire pump compartment (currently unable to achieve suction) prior to departure from port. _x001C_ _x001C_ SOLAS CH II-2, REG 21 (1.1)
Condition: Unknown
Due 31 August 1995
Resolved 1 September 1995
Accommodation/Occupational Safety
Issued 29 August 1995 Resolved
Repair fractures to rails located on port side in way of the #2 cargo hold.(uprights fractures on both sides) prior to next U.S. port call _x001C_ _x001C_ ILO 147
Condition: Unknown
Due 26 December 1996
Resolved 26 December 1996
Engineering
Issued 29 August 1995 Resolved
Make permanent repairs and provide class report on 1) patched diesel oil purifier suction pipe 2) leaking port port S/W discharge pipe to M/E air cooler 3) patched S/W discharge pipe to #1 generator air cooler _x001C_ SOLAS II-2, 26.1
Condition: Unknown
Due 31 August 1995
Resolved 1 September 1995
Fire Fighting
Issued 16 May 1994 Resolved
DURING THE DECK WALK THE BOARDING TEAM DISCOVERED THAT THE VESSEL WAS MISSING FOUR (4) NOZZLES FROM DECK FIRE STATIONS. THE MASTER PRODUCED PAPERWORK THAT SHOWED THAT HE HAD ORDERED REPLACEMENTS BUT HAD RECEIVED THE WRONG TYPE FOR HIS VESSEL'S SYSTEM.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.