MOONDANCER is a 1983 freight ship. The Coast Guard has recorded 15 inspections since 1986, most recently in September 2001, along with 15 deficiencies and 2 operational controls, 1 with no removal date recorded.

Records from 1986 to 2001. Most recent: operational control imposed, 6 September 2001.

Built
1983
Last inspected
6 September 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8020551 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
226954
Flag
LIBERIA
—
Maury page id
psix-226954

Inspections, by type

…with no type recorded11
Years with a record 9 calendar years (1986–2001)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it39624 - Regulatory (Subpart C or D), Net Ton
70872 - Regulatory (Subpart C or D), Gross Ton
135160 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

6 September 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 293600
10 June 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 391985
23 February 1994 Damage Survey · Examination of Repairs
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1163972
17 February 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 488784
22 July 1993 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 359736
28 May 1993 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 529370
28 May 1993 Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1134406
21 March 1991 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 459191
23 September 1990 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 339286
10 March 1990 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 473261
21 August 1989 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1208618
3 October 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 443231
8 February 1987 Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1318403
1 November 1986 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 493369
10 February 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 306905

Deficiency record · 15

Fire Fighting
Issued 6 September 2001 Resolved
#1 and #2 fire pumps are leaking and spraying excessively. Make permanent repairs to the satisfaction of class.
Condition: Unknown
Due 10 September 2001
Resolved 14 September 2001
Lifesaving
Issued 6 September 2001 Resolved
#2 Heavy Fuel Oil Pump has standing oil in housing case and in deck containment area. Clean pump and deck area to satisfaction of Coast Guard Inspector.
Condition: Unknown
Due 10 September 2001
Resolved 14 September 2001
Unknown
Issued 6 September 2001 Resolved
Outlet piping from#2 General service pipe has a leaking temporary soft patch. Make permanent repairs to the satisfaction of class.
Condition: Unknown
Due 10 September 2001
Resolved 14 September 2001
Engineering
Issued 6 September 2001 Resolved
#2 Lube oil purifier has flexible rubber hose which extends from L/O coolerto purifier. Make permanent repairs to the satisfaction of class.
Condition: Unknown
Due 10 September 2001
Resolved 14 September 2001
Lifesaving
Issued 6 September 2001 Resolved
#1 F/W central cooler has elbow section of pipe missing. The remaining section is spraying into the bilge. Make permanent repairs to the satisfaction of class.
Condition: Unknown
Due 10 September 2001
Resolved 14 September 2001
Lifesaving
Issued 6 September 2001 Resolved
#1 standby control fresh water cooler cylinder is spraying water. Make permanent repairs to the satisfaction of class.
Condition: Unknown
Due 10 September 2001
Resolved 14 September 2001
Lifesaving
Issued 6 September 2001 Resolved
Main Engine is covered with oil. Clean all oil off engine to the satisfaction of U.S. Coast Guard.
Condition: Unknown
Due 10 September 2001
Resolved 14 September 2001
Lifesaving
Issued 6 September 2001 Resolved
Bilge has excess oil and water. Remove all oil and water to satisfaction ofU.S. Coast Guard.
Condition: Unknown
Due 10 September 2001
Resolved 14 September 2001
Lifesaving
Issued 6 September 2001 Resolved
#1, #2, and #3 Auxilary engine generators are covered in oil. Clean to the satisfaction of U.S. Coast Guard.
Condition: Unknown
Due 10 September 2001
Resolved 14 September 2001
Accommodation/Occupational Safety
Issued 6 September 2001 Resolved
Starboard side accomodation ladder control box is leaking hydrualic fluid. Fluid is leaking to deck. Repair and clean to the satisfraction of class.
Condition: Unknown
Due 10 September 2001
Resolved 14 September 2001
Deck/Cargo
Issued 6 September 2001 Resolved
Portside controls for #6 and #7 cargo holds have excessive hydraulic leaks.Repair and clean to the satisfaction of clas.
Condition: Unknown
Due 10 September 2001
Resolved 14 September 2001
Deck/Cargo
Issued 6 September 2001 Resolved
Junction box starboard side #4 hold jack is holed, wasted, and leaking hydraulic fluid. Make repairs to the satisfaction of class.
Condition: Unknown
Due 10 September 2001
Resolved 14 September 2001
Deck/Cargo
Issued 6 September 2001 Resolved
All hydraulic equipment inside forecastle is leaking hydraulic fluid. Make permanent repairs and clean all standing hydraulic fluid to class satisfaction.
Condition: Unknown
Due 10 September 2001
Resolved 14 September 2001
Documentation
Issued 6 September 2001 Resolved
Oil Transfer Procedures are not in accordance with 33 CFR 155.750. New oil transfer procedures must be submitted and approved by U.S. Coast Guard prior to departure. Bunkering is prohibited until proceedures are in compliance with 33 CFR.750.
Condition: Unknown
Due 6 September 2001
Resolved 14 September 2001
Construction/Loadline
Issued 10 June 1996 Resolved
Fracture in deck radius of aft port corner of # 3 hold hatch. Class attended vsl, temp repairs required and completed. Condition of class imposed for permanent repairs to be completed not later than 31JUL96.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.