Records from 1985 to 2006. Most recent: operational control imposed, 8 February 2006.
Inspection history · 51
8 February 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2581377
7 February 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2581508
1 February 2006
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2577736
11 November 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2532910
10 November 2005
ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2532197
7 January 2005
PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2270405
12 October 2004
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2218712
8 December 2003
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1960287
8 July 2003
Deficiency Check · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1839581
28 April 2003
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 1781845
28 April 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1783849
27 April 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1783461
13 February 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1745565
12 February 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1745932
9 October 2002
Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1690990
4 September 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1670965
3 September 2002
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1668547
3 September 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1670039
3 September 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1670431
16 June 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1631511
28 May 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1621944
28 April 2002
In-Service Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1610312
3 April 2002
MARPOL Annex V Examination · MARPOL Annex I Examination · Re-Inspection · Administrative Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1600619
19 June 2001
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 291067
19 April 2000
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 276957
19 July 1999
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 430748
14 May 1999
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 428555
4 April 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 402241
7 December 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 373088
1 December 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 473836
7 July 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 685348
27 June 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 368047
21 April 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 672925
5 April 1993
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 357411
8 March 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 496064
18 May 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 350809
18 May 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 672921
18 September 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 649539
28 July 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 505072
25 October 1990
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 340001
12 April 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 442836
18 September 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 332699
14 February 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 493651
16 August 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 325109
12 May 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 316019
3 December 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 313010
7 November 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 474744
3 May 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 308521
12 November 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 536476
24 July 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 511808
6 January 1985
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 299730
Engineering › Steering Gear System › Pump
Issued 8 February 2006
Resolved
Subject vessel suffered a steering casualty during the outbound transit in the Port of Hampton Roads. Vessel directed to Cape Charles Anchorage until satisfactory repairs have been conducted to the satisfaction of the attending Classification Society Surveyor. Surveyor report shall be submitted to this office prior to releasing the vessel.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 8 February 2006
Resolved 8 February 2006
Resolution: Received survey report from vessel''s Classification [name withheld] attesting to satisfactory repairs and normal operation of the vessel''s steering casualty. Vessel is released from COTP Order 06-037.
Construction/Loadline › Markings › Load Line Mark
Issued 1 February 2006
No resolution recorded
Repaint Loadline
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 March 2006 — due date passed with no resolution recorded
Lifesaving › Launching Appliances › Davit
Issued 1 February 2006
No resolution recorded
Ensure portside lifeboat launching appliance is operational
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 March 2006 — due date passed with no resolution recorded
Engineering › Freshwater Generation System › Piping
Issued 7 January 2005
Resolved
S/W discharge pipe for F/W generator is holded, wasted, & leaking and has temp repair. Renew/repair to the satisfaction of class.
Action required: 705 - Other - as specified
Due 7 February 2005
Resolved 2 February 2005
Resolution: Received Class Report attesting to repair consisting of renewed pipe.
Engineering › Freshwater Generation System › Piping
Issued 7 January 2005
Resolved
Brine discharge pipe for f/w generator is fractured and leaking. Renew/repair to the satisfaction of class.
Action required: 705 - Other - as specified
Due 7 February 2005
Resolved 2 February 2005
Resolution: Received Class Report attesting to repairs consisting of renewed pipe.
Engineering › Freshwater Generation System › Pump
Issued 7 January 2005
Resolved
Flag state to attest to the condition of the f/w generator ejector and make reccommendation.
Action required: 705 - Other - as specified
Due 7 February 2005
Resolved 2 February 2005
Resolution: Received Class report attesting repairs consiting of renewed eductor
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 12 October 2004
Resolved
COOLING WATER RETURN PIPE FOR FORWARD TURBOCHARGER AFTERCOOLER HAS SMALL LEAK. CLASS SOCIETY TO MAKE RECOMMENDATIONS FOR PERMANANT REPAIRS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 November 2004
Resolved 6 November 2004
Resolution: Received class report. Following repair was carried out: Hold and leaky cooling water return pipe for forward turbocharger after cooler has been renewed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 12 October 2004
Resolved
EMERGENCY ESCAPE DOOR FROM STEERING GEAR ROOM IS WASTED AROUND THE WATER TIGHT SEAL. CLASS SOCIETY TO MAKE RECOMENDATIONS FOR PERMANANT REPAIRS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2004
Resolved 6 November 2004
Resolution: Received class report. Following repair was carried out: Emergency escape door from steering gear room which was wasted around the watertight seal, has been renewed completely.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 12 October 2004
Resolved
SECURITY LATCH ON EMERGENCY ESCAPE DOOR FROM STEERING GEAR ROOM DOES NOT SECURE THE DOOR. RECTIFY TO SATISFACTION OF RECOGNIZED SECURITY ORGANIZATION.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2004
Resolved 12 October 2004
Resolution: OPENED UNDER WRONG SUB-SYSTEM
Engineering › Fuel Oil Service System
Issued 8 July 2003
Resolved
The air flask for the remote engine room fuel oil valve shut downs was found empty. Maintain pressure as required at all times. Corrected on the spot. SOLAS II-2/15 LEGACY COMPONENT DESC: Valve, Control
Due 8 July 2003
Resolved 8 July 2003
Deck/Cargo › Cargo Stowage
Issued 8 July 2003
Resolved
Remove 55 gallon drums near steering room that block the closing of the fire door between Car Deck #6 and the steering room. ICLL 66 & SOLAS 74 I/II
Due 8 July 2003
Resolved 8 July 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 8 July 2003
Resolved
Fabricate and install a hand guard at the emergency fire pump belt driven priming pump. SOLAS 74 I/II, ILO 147 LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 15 - Rectify deficiencies by next port
Resolved 8 December 2003
Resolution: CORRECTED TO THE SATISFACTION OF MARINE INSPECTOR.
Construction/Loadline › Structures
Issued 8 July 2003
Resolved
Make the A-class doors at the engine room entrances self-closing as original where the ventilation system of the engine room is out of balance and the supply air is holding the doors open against the self-closing mechanisms. ICLL66 & SOLAS 74 I/II LEGACY COMPONENT DESC: Door
Action required: 15 - Rectify deficiencies by next port
Resolved 8 December 2003
Resolution: CORRECTED TO THE SATISFACTION OF THE MARINE INSPECTOR.
Electrical › Lighting (service)
Issued 28 April 2003
Resolved
Safety cover missing from one light fixture located in engine control room behind high voltage panel. Also after-steering lightfixture broken. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 July 2003
Electrical › Lighting (service)
Issued 28 April 2003
Resolved
Insalation missing , not conected to flange of electrical valve on OWS. Red and Black wire exposed. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 July 2003
Construction/Loadline › Hull
Issued 27 April 2002
Resolved
Classification Society verify hull-plating in number three cargo hold, frame 114, ensure that hull plating is in satisfactory condition (ILLC 66 Annex 1/1). LEGACY COMPONENT DESC: Side Shell
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 27 April 2002
Resolved 28 May 2002
Resolution: Received fax NKK survey report which indicated item corrected to the satisfaction of class.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 27 April 2002
Resolved
Classification Society to verifiy condition of Main Engine Turbo Charge, number one (forward) (SOLAS 74 11-2/1 or 2/2). LEGACY COMPONENT DESC: Turbocharger
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 27 April 2002
Resolved 28 May 2002
Resolution: Received NKK report that item was corrected to the satisfaction of class
Lifesaving › Lifeboat
Issued 27 April 2002
Resolved
Classification Society evaluate and correct rusted piping and old cracked electrical cable in area near Port Lifeboat (SOLAS 74 111/19.2). LEGACY COMPONENT DESC: Embarkation/Disembarkation Capabilities
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 27 April 2002
Resolved 28 May 2002
Resolution: Received NKK report which indicated item was corrected to the satisfaction of class
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 April 2002
Resolved
Major Oil leaks located on the MDE. Various catch buckets placed throughout engine room. Leaking oil also making engine room deckplates extremely slippery. Excessive oil found in the bilges. Class to witness resolution of problem and provide proof thereof. LEGACY COMPONENT DESC: Crankcase
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 6 April 2002
Resolution: NKK provided class survey, deficiency resolved.
Engineering › Lubricating Oil Service System
Issued 3 April 2002
Resolved
Dead end wiring for LOP. LOP not fully operational due to wires not being connected. Only can be used via manual operation. Class to prove proper operation and provide proof thereof. LEGACY COMPONENT DESC: Purifier
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 6 April 2002
Resolution: NKK class resolved deficiency.
Accommodation/Occupational Safety › Occupational Safety
Issued 3 April 2002
Resolved
Steps on ladders in two locations rusted through to the point of being trip hazards. Bottom steps of both ladder port side of bridge and ladder forward going down to focsle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 6 April 2002
Resolution: NKK Provided class survey.
Fire Fighting › Fire Pumps
Issued 3 April 2002
Resolved
Lube oil being used to prime emergency fire pump suction. Oil is then discharged through firehose creating a visible sheen. LEGACY COMPONENT DESC: Arrangement
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 6 April 2002
Resolution: NKK Class resolved defiency.
Electrical
Issued 19 June 2001
Resolved
Explosion proof lighting covers need to installed throughout engine room.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Lifesaving
Issued 14 May 1999
Resolved
Repair or replace the life ring deployment system on the port and stbd sidebridge wings so that when the pin is pulled to deploy the life ring the smoke and strobe light will also be deployed as well.
Condition: Unknown
Due 23 July 1999
Resolved 23 July 1999
Engineering
Issued 27 June 1994
Resolved
INDICATOR GAUGE ON OILY WATER SEPERATOR NOT WORKING.
Condition: Unknown
Due 1 December 1994
Resolved 1 December 1994
Navigation
Issued 18 May 1992
Resolved
CHART 18441 WAS MISSING 44/91 (2 CORRECTIONS) AND 51/91 (1 CORRECTION)._x001C_ CHART 18474 WAS MISSING 43/91 (1 CORRECTION).
Condition: Unknown
Due 18 May 1992
Resolved 18 May 1992
Navigation
Issued 25 October 1990
Resolved
33 CFR 164.33(a)(3)(ii)_x001C_ Vessel failed to have a copy of the Tidal Current Tables on board, or a foreign equivalent of that publication._x001C_ _x001C_
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990