← All vessels
AGIA SOFIA
Freight Ship · Bulk Carrier class · Built 1980s · USCG Heartland District (CGD-H) · Other hulls named AGIA SOFIA
AGIA SOFIA is a 1981 freight ship. The Coast Guard has recorded 39 inspections since 1988, most recently in May 2007, along with 21 deficiencies and 6 operational controls.
Records from 1988 to 2007. Most recent: operational control imposed, 25 May 2007.
- Built
- 1981
- Last inspected
- 25 May 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 21 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8023321 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HGS4
226981
Flag
LIBERIA
—
Maury page id
psix-226981
Inspections, by type
…with no type recorded30
Years with a record
16 calendar years (1988–2007)
The 39 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it13416 - Convention (Subpart B), Net Ton
20468 - Convention (Subpart B), Gross Ton
35063 - Dead Weight, Ton
42676 - Displacement, Ton
20468 - Convention (Subpart B), Gross Ton
35063 - Dead Weight, Ton
42676 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 39
25 May 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2940365
25 May 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2941987
25 May 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2953414
7 May 2007
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2924033
6 May 2007
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2923192
9 December 2005
PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2548627
2 March 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2302589
2 March 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2321617
3 November 2004
ISPS II Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2233404
23 August 2004
PII Safety Exam · MARPOL Annex V Examination · ILO-147 Exam · Loadline Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2171670
4 May 2004
Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2059115
2 January 2004
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1973430
16 January 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1732173
16 January 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1732176
6 December 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1712486
31 May 2001
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 290469
8 August 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 80917
3 August 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 280685
1 December 1999
Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 435140
26 October 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 647994
13 October 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 433691
22 January 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 424665
1 July 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 417477
28 June 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 417506
23 November 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 410269
11 September 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 465864
4 September 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 407462
9 November 1996
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 397452
20 April 1996
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 390107
22 October 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 384030
16 October 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 383816
10 June 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 379425
25 May 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 378783
16 November 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 372449
4 November 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 372172
4 November 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1179545
9 April 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 342825
29 August 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 332393
26 April 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 322905
Deficiency record · 21
Engineering › Sea-water System (primary cooling) › Pump
Issued 25 May 2007
Resolved
Vessel experienced a power irregularity while transiting out of the Lower Mississippi River.
Fire Fighting › Self-contained Breathing Apparatus › Quantity
Issued 7 December 2005
Resolved
NOTE: DEFICIENCIES ARE FOR EEBD's NOT SCBA.
02 EEBD's in engine room are empty. EEBD's need to be filled prior to departure from port and approved by a Coast Guard. SOLAS Ch. II-2 Reg. 13.3.4
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 August 2004
Resolved
Fire Control Plan incomplete/incorrect. Plan must be updated to show, clearly for each deck, fire sections enclosed by "B" boundries. Identification numbers of the fans in the ventilation system and means of access to different compartments. Correct to the satisfaction of class prior to 23SEP04.
Electrical › Electrical Distribution System (service)
Issued 2 January 2004
Resolved
The main switchboard has electrical cables connected to the back of the 220v/48v panel running the length of the switchboard leading into a ventilation duct mounted in the bulkhead. Class to attest to the arrangement. LEGACY COMPONENT DESC: Switchboard
Documentation
Issued 13 October 1999
Resolved
VESSEL'S CARGO SHIP SAFETY CONSTRUCTION CERTIFICATE WAS EXPIRED. VESSEL REQUIRED TO HAVE APPROVED CURRENT CERTIFICATE AS PER SOLAS CHAPTER 1 REGULATION 8.
Navigation
Issued 13 October 1999
Resolved
VESSEL FAILED TO HAVE AN OPERATING ECHO DEPTH SOUNDING DEVICE RECORDER AS PER 33 CFR 164.35(I).
Fire Fighting
Issued 22 January 1999
Resolved
REPAIR/RENEW AS ORIGINAL EMERGENCY FIRE PUMP TO THE SATISFACTION OF COAST GUARD MARINE INSPECTOR OR LLOYDS REGISTRY SURVEYOR PRIOR TO LEAVING THE PORT OF PASCAGOULA, MISSISSIPPI.
Documentation
Issued 4 September 1997
Resolved
CLASS SOCIETY TO EXAMINE THE IOPP CERTIFICATE FORM A AND UPDATE THE OILY WATER SEPERATOR SECTION.
Fire Fighting
Issued 4 September 1997
Resolved
DEMONSTRATE SATISFACTORY FIRE AND ABANDON SHIP DRILL.
Lifesaving
Issued 4 September 1997
Resolved
DEMONSTRATE THAT PORT LIFEBOAT CAN BE LOWERED AND RAISED TO THE SATISFACTION OF CLASS.
Lifesaving
Issued 22 October 1995
Resolved
TWO ONBOARD SELF-IGNITING LIGHTS FOR THE PORT AND STARBOARD LIFEBUOYS ON THE 02 LEVEL WERE REPLACED AND IN WORKING ORDER.
Lifesaving
Issued 16 October 1995
Resolved
PROVIDE ONBOARD TWO SELF-IGNITING LIGHTS FOR THE PORT AND STARBOARD LIFEBUOYS ON THE 02 LEVEL._x001C_ _x001C_ SOLAS 74/88 III/7 & 31
Fire Fighting
Issued 25 May 1995
Resolved
FIREMAIN LINE HAS A LEAK ON THE STARBOARD SIDE OF THE #2 CARGO HOLD. PERMANENT REPAIRS MUST BE MADE TO FIREMAIN PRIOR TO ENTRY INTO THE NEXT U.S. PORT.
Engineering
Issued 4 November 1994
Resolved
OILY WATER SEPARATOR PUMP LEAKING.
Navigation
Issued 4 November 1994
Resolved
LEAKING STBD HYDRAULIC WINCH PUMP IN STEERING ROOM.
Engineering
Issued 9 April 1991
Resolved
BILGE MONITER ALARM FAILED TO SOUND WHEN OIL IN WATER MIXTURE ROSE ABOVE 15PPM AFTER 3 MINUTES ALARM DID WEEKLY SOUND A PROPERLY CALIBRATED MONITER_x001C_ ALARM SHOULD NORMALY SOUND AFTER 20 SECONDS_x001C_ _x001C_
Accommodation/Occupational Safety
Issued 9 April 1991
Resolved
MSD WAS NOT PROPERLY LABELD AS PER 33 CFR 159.55
Navigation
Issued 9 April 1991
Resolved
VESSEL DID NOT HAVE A STEERING GEAR CHANGE OVER BLOCK DIAGRAM AS PER 33 CFR 164.35 (k)_x001C_
Documentation
Issued 26 April 1988
Resolved
33CFR155.750(A) INCOMPLETE OIL TRANSFER PROCEDURES.
Navigation
Issued 26 April 1988
Resolved
33CFR164.33(A)(2)(II) COAST PILOT VOLUME 5 WAS UNCORRECTED.
Navigation
Issued 26 April 1988
Resolved
33CFR164.33(A)(1)(II) CHARTS 11324, 11327, 11328 AND 11329 NOT CORRECTED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.