Records from 1986 to 2011. Most recent: inspection, 17 December 2011.
Inspection history · 42
17 December 2011
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4210030
23 December 2010
Ballast Water Examination · PII Safety Exam · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3911111
22 December 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3911113
22 December 2010
Type not recorded
No type recorded · USCGC PELICAN (WPB 87327) · USCG Heartland District (CGD-H) · Activity 3922009
16 December 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3912154
29 March 2010
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3704543
7 August 2008
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3284422
26 October 2005
MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2522598
22 January 2004
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1990783
10 November 2003
Ballast Water Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1945366
26 June 2002
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1636745
7 March 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 526892
6 March 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 287845
5 March 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 53871
5 March 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 486880
23 December 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 436112
10 June 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 429561
26 April 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 403022
23 December 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 398725
18 April 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 389983
9 February 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 92799
30 January 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 387179
14 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 377364
6 November 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 155669
15 September 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 370474
15 September 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 868691
2 September 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 370136
2 September 1994
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 863062
5 August 1994
Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 862669
24 July 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 490818
5 July 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 178017
5 July 1994
Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1394146
9 October 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 361339
4 October 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 353440
19 May 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 343895
18 July 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 338263
8 June 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 330827
21 February 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 497683
28 June 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 324057
23 April 1987
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 315396
19 September 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 457055
26 March 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 307696
Electrical › Lighting (service) › Lighting Feeder
Issued 23 December 2010
No resolution recorded
0830 - Pipes wires (insulate) accident prev. - Multiple portable light assemblies, for lighting of cargo holds, power cords have failed and have been temporarily taped back together. Reinstall as original. - SOLAS 74am I/11 -
Action required: 705 - Other - as specified
Due 30 December 2010 — due date passed with no resolution recorded
Resolution: Vessel replaced and/or repaired power cords.
Pollution Prevention/Response › Response Equipment › Containers
Issued 23 December 2010
Resolved
2120 - Garbage - Approximately 20 empty waste oil drums are located in the focsle. Dispose of all waste oil drums iaw garbage waste management plan- MARPOL 73/78 Annex5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 December 2010
Resolved 3 March 2011
Resolution: Vessel had no waste oil drums stored in the forecaslte at the time of the inspection.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 March 2010
Resolved
While conducting operational test of the OWS, PSCO observed that the OCM sample line valve on the discharge side of OWS was closed preventing OCM from getting a PPM sample of effluent. Once sample valve was opened the OCM immediately registered 40-50 ppm, causing the OWS audible alarm to sound, and the pump to stop. Following this, OCM was flushed with clean water and was tested 2 additional times
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2010
Resolution: Received class report attesting to the proper operation of the OWS. Condition of class also imposed for temporary repair (soft patch) on OWS overboard line to be examined and dealt with as necessary no later than 6/30/2010.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 March 2010
Resolved
The OCM is a MEPC. 107(49) designed unit and therefore must be constructed so the alarm is always activated whenever clean water is used for cleaning or zeroing purposes to prevent willful manipulation of the unit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2010
Resolution: Received class report attesting to the proper repairs and installation of the OCM so that is relects the piping diagram on the installation manual.
Lifesaving › Launching Appliances › Winch
Issued 29 March 2010
Resolved
Air winch was unable to recover the lifeboat because it wasn't working. Crew had to hand crank it up. Solas 74, III/36(i)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2010
Resolution: Received class report attesting to repair of pneumatic winch and quick retrieval of port side lifeboat/rescue boat using winch.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 29 March 2010
Resolved
The diesel engine for the Emergency Firepump has a small exhaust leak that is slowly filling the space up with smoke when running. It provides adequate pressure but, is a health hazard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2010
Resolution: Received class report attesting to the proper operation of the emergency fire pump. Exhaust fumes were traced to small oil and exhaust gas leakage on hot surfaces. Condition of class imposed to be dealt with by 6/30/2010 for idenification and repairs.
Engineering › Compressed Air System (control) › Piping
Issued 29 March 2010
Resolved
Air pressure line for ships horn up on the bow has a substantial size hole in it.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2010
Resolution: Received class report attesting to proper repairs of the air piping leading to the forward ships horn.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 7 August 2008
Resolved
Class "B" door missing for officers laundry room leading from passageway. Correct to the satifaction of attending class surveyor.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 August 2008
Resolved 29 March 2010
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 August 2008
Resolved
Vessel's Fire Control Plan dose not identify class "A" or "B" boundries.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 August 2008
Resolved 29 March 2010
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 7 August 2008
Resolved
One of ten EEBA's had no air in the bottle thus reducing the number required on board according to the vessel's FCP
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 August 2008
Resolved 29 March 2010
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 7 August 2008
Resolved
OWS content meter was inoperable. Vessel had new one on board but no tech to repair.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 August 2008
Resolved 29 March 2010
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 7 August 2008
Resolved
Two of the three bilge alarms in engine room (porside forward & aft) not operational.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 August 2008
Resolved 29 March 2010
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 August 2008
Resolved
Vessel's secondary radar was not operational upon arrival. Tech on board and repaired prior to boarding team departing.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2008
Resolved 7 August 2008
Resolution: Tech on board, repaired, tested and submitted report to boarding team.
Lifesaving › Inflatable Liferafts › Servicing
Issued 26 October 2005
No resolution recorded
REPLACE BURSTING STRAPS ON STBD SIDE LIFERAFT THAT WERE REMOVED BY THE VESSEL CREW ON ACCIDENT.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolution: RECEIVED FAX FROM SERVICING COMPANY STATING THAT STRAPS WERE REPLACED.
Fire Fighting › Emergency Fire Pumps › Location
Issued 26 October 2005
Resolved
CURRENT LOCKING ARRANGEMENT FOR STEERING GEAR ROOM DOOR PREVENTS SECONDARY ACCESS TO EMERGENCY FIRE PUMP FROM MAIN DECK. (EXAMPLE OF LOCKING ARRANGEMENT EXPLAINED TO MASTER).
RECTIFY TO THE SATISFACTION OF CLASS SURVEYOR.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 August 2008
Fire Fighting › Structural - Main Vertical Zones
Issued 10 November 2003
Resolved
MAIN VERTICAL STAIRWELL DOORS TO BE FITTED WITH SEALING INSULATION STRIPS TO PREVENT THE PASSAGE OF SMOKE/ FLAME. CLASS REPORT TO BE PROVIDED. SOLAS 60/II/REG 38 LEGACY COMPONENT DESC: FIRE DOORS
Action required: 15 - Rectify deficiencies by next port
Due 10 December 2003
Resolved 10 January 2004
Resolution: SEALING INSULATION STRIPS NOW FOUND ON STAIRWELL DOOR FRAMES.
Fire Fighting
Issued 10 November 2003
Resolved
FIRE CONTROL PLAN TO BE MODIFIED TO INDICATE "A" AND "B" SUBDIVISIONS. HAVE CLASS APPROVE PLAN AND INSURE ALL UPDATES ARE INCLUDED. SOLAS 60/II/REG 20
Action required: 15 - Rectify deficiencies by next port
Due 10 December 2003
Resolved 10 January 2004
Resolution: FIRE CONTROL PLAN UPDATED AND ENDORSED BY LLOYDS.
Construction/Loadline › Structures
Issued 10 November 2003
Resolved
BATTERY ROOM LOWER VENTILATOR CLOSURE TO BE REPAIRED TO THE SATISFACTION OF ATTENDING USCG INSPECTOR. ILLC 66 ANNEX I/15 LEGACY COMPONENT DESC: Ventilators
Condition: Unknown
Due 10 December 2003
Resolved 10 January 2004
Resolution: Received survey from class Lloyds dated 01/10/2004 attesting to ventilator closure being repaired and inspected to satisfaction.
Pollution Prevention/Response › Prevention Equipment
Issued 10 November 2003
Resolved
OILY WATER SEPARATOR SENSOR TO BE RECALIBRATED AND CERTIFIED BY FLAG STATE. REPORT TO BE PROVIDED BY CLASS. MARPOL 73/78 ANNEX I/16 LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 15 - Rectify deficiencies by next port
Due 10 December 2003
Resolved 10 January 2004
Resolution: OIL CONTENT METER MODEL: ET-35A, MAKER SHIMADZU CORP. JAPAN NOW TESTED BY MAKER''S REP O SATISFACTION. TEST REPORT PROVIDED.
Navigation › Piloting/Steering
Issued 10 November 2003
Resolved
CLASS TO SURVEY SUITABILITY OF CONTINUED USE OF MAGNETIC COMPASS IN STEERING ROOM. EXISTING ARRANGEMENTS TO BE ASSESSED BY CLASS AND PROVIDE COMPASS DEVIATION TABLE. SOLAS 60/I/REG 10 LEGACY COMPONENT DESC: Magnetic Compass
Due 10 December 2003
Resolved 10 January 2004
Resolution: Received class survey dated 01/10/2004 attesting, gyro repeater found provided for steering gear room.
Lifesaving
Issued 6 March 2001
Resolved
Hydrostaticly test all bunker piping, valves, and flanges. 33 CFR 156.170.Provide test certificate prior to next U.S. port.
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Documentation
Issued 6 March 2001
Resolved
Provide Oil Transfer Procedures prior to any transfer of oil._x001C_ 33 CFR 155.750.
Condition: Unknown
Due 6 March 2001
Resolved 6 March 2001
Fire Fighting
Issued 10 June 1999
Resolved
REPAIR TEMP PATCH ON FIRE MAIN FWRD,STARB, CARGO HATCH # 6
Condition: Unknown
Due 28 December 1999
Resolved 28 December 1999
Fire Fighting
Issued 26 April 1997
Resolved
RENEW WASTED FIRE MAIN LINE (3" TRANSVERSE IN THE AFT STBD CORNER, OF THE #6 CARGO HOLD, (IN WAY OF PIN HOLE) PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Fire Fighting
Issued 18 April 1996
Resolved
RENEW MISSING NATURAL VENTILATION CLOSURE FOR EMERGENCY BATTERY STORAGE ROOM. SOLAS 74 II-2/25(C)
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Fire Fighting
Issued 18 April 1996
Resolved
PROVIDE ON BOARD VESSEL AN ELECTRIC SAFETY LAMP FOR THE FIREMANS OUTFIT LOCATED IN THE SAFETY EQUIPMENT LOCKER PORT SIDE BOAT DECK. SOLAS 74 (AMENDED) II-2/17.1.1.4
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Lifesaving
Issued 18 April 1996
Resolved
PROVIDE ON BOARD EACH LIFEBOAT, WATERTIGHT RECEPTACLES CONTININ 3 LITRES OFFRESH WATER FOR EACH PERSON THE LIFEBOAT IS CERTIFIED TO CARRY. SOLAS 74 III/11(a)(xiii)
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Lifesaving
Issued 18 April 1996
Resolved
PROPERLY SECURE HIGH PRESSURE GAS CYLINDERS STOWED ON THE POOP DECK.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Fire Fighting
Issued 18 April 1996
Resolved
RENEW MISSING GASKET TO NATURAL VENTILATION CLOSURE LOCATED ON THE PORT BOAT DECK. SOLAS 74 II-2/25(c)
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Engineering
Issued 18 April 1996
Resolved
PROVIDE ON BOARD VESSEL 6 BOLTS 20MM IN DIAMETER AND A GASKET OF AN OIL PROOF MATERIAL FOR THE STARDARD DISCHARGE CONNECTION. 33 CFR 155.430
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Lifesaving
Issued 18 April 1996
Resolved
PROVIDE AN EXPOSURE COVER OF A HIGHLY VISIBGLE COLOR CAPABLE OF PROTECTING THE LIFEBOAT OCCUPANTS AGAINST INJURY BY EXPOSURE. ENSURE THE COVER PROPERLY FITS THE LIFEBOAT. SOLAS 74 III/11(a)(xxvi)
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Fire Fighting
Issued 18 April 1996
Resolved
RENEW/REPAIR INOPERABLE VENTILATION DAMPER LOCATED PORT SIDE ON THE POOP DECK. SOLAS 74 II-2/25(c)
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Fire Fighting
Issued 18 April 1996
Resolved
PROVJIDE 4 BOLTS, 16 MILIMETERS IN DIAMETER AND 50 MILLIMETERS IN LENGTH WITH FOUR NUTS AND EIGHT WASHERS FOR THE INTERNATIONAL SHORE CONNECTION. SOLAS 74 II-2/5(h)
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Fire Fighting
Issued 18 April 1996
Resolved
REPAIR ALL FIRE HYDRANTS LOCATED ON THE MAIN DECK TO PROVIDE SMOOTH OPERATION. ENSURE EACH HYDRANT IS ABLE TO BE COMPLETELY SHUT OFF. SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Fire Fighting
Issued 18 April 1996
Resolved
RENEW/REPAIR INOPERABLE VENTILATION CLOSURE LOCATED AFT OF #3 CARGO HOLD. SOLAS 74 II-2/25(c)
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Fire Fighting
Issued 18 April 1996
Resolved
PROVIDE ON BOARD VESSEL RELIEF VALVES IN CONJUNCTION WITH ALL FIRE PUMPS TOPREVENT EXCESSIVE PRESSURE IN ANY PART OF THE FIRE MAIN SYSTEM. SOLAS 74 II-2/5(b)(iii)
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Lifesaving
Issued 18 April 1996
Resolved
REMOVE PAINT AND OTHER FLAMMABLE LIQUIDS STORED OUTBOARD THE ENGINE CONTROLROOM. PAINT AND OTHER FLAMMABLES SHALL BE STORED IN A LOCKER WITH AN APPROPIRATE FIRE EXTINGUISHING ARRANGEMENT. SOLAS 74 (AMENDED) II-2/18.7
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Fire Fighting
Issued 18 April 1996
Resolved
RENEW/REPAIR INOPERABLE VENTILATION DAMPER LOCATED ON THE MAIN DECK SFT OF #6 CARGO HOLD STARBOARD SIDE. SOLAS 74 II-2/25(c)
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Lifesaving
Issued 18 April 1996
Resolved
REMOVE ALL PAINT AND FLAMMABLE LIQUIDS STORED IN THE DECK HOUSE LOCATED BETWEEN #5 & #6 CARGO HOLDS. SOLAS 74 (AMENDED) II-2/18.7
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Lifesaving
Issued 18 April 1996
Resolved
RENEW DETERIORATED RETRO-REFLECTIVE MATERIAL TO PORT AND STARBOARD LIFEBOATS IN ACCORDANCE WITH THE REQUIREMENTS OF IMO RESOLUTION A.658(16). SOLAS 74 (AMENDED)III/30.2.7
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Lifesaving
Issued 18 April 1996
Resolved
RENEW DETERIORATED RING LIFE BOUY LOCATED ON THE STARBOARD BRIDGE WING. SOLAS 74 (AMENDED) III/19.2
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Fire Fighting
Issued 18 April 1996
Resolved
PROVIDE ON BOARD VESSEL INSTRUCTIONS FOR THE MAINTENANCE AND OPERATION OF ALL ON BOARD EQUIPMENT/INSTALLATIONS FOR FIGHTING AND CONTAINMENT OF FIRE. SOLAS 74 (AMENDED)II-2/20.1
Condition: Unknown
Due 26 December 1996
Resolved 26 December 1996
Lifesaving
Issued 18 April 1996
Resolved
RENEW DETERIORATED RING LIFEBOUY LOCATED AFT ON THE BRIDGE DECK. SOLAS 74 (AMENDED) III/19.2
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Navigation
Issued 14 April 1995
Resolved
MAKE PROPER AND PERMENANT REPAIRS TO STEERING GEAR. HYD LEAK STBD SIDE SMALL HYD RAM. LEAKS EXCESSIVELY UNDER PRESSURE.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Engineering
Issued 14 April 1995
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPERATOR.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Documentation
Issued 14 April 1995
Resolved
PROVIDE ONBOARD CURRENT SAFE MANNING CERTIFICATE.
Condition: Unknown
Due 5 February 1996
Resolved 5 February 1996